Evaluation of Methods for Generating Parametric (R)-[11C]PK11195 Binding Images
暂无分享,去创建一个
Ronald Boellaard | Alie Schuitemaker | Philip Scheltens | Adriaan A Lammertsma | Cees Jonker | Marc A Kropholler | Bart N M van Berckel | Reina W Kloet | R. Boellaard | P. Scheltens | A. Lammertsma | M. Kropholler | A. Schuitemaker | B. V. van Berckel | C. Jonker | R. Kloet
[1] R B Banati,et al. In vivo visualization of activated glia by [11C] (R)-PK11195-PET following herpes encephalitis reveals projected neuronal damage beyond the primary focal lesion. , 2001, Brain : a journal of neurology.
[2] Michel Defrise,et al. Exact and approximate rebinning algorithms for 3-D PET data , 1997, IEEE Transactions on Medical Imaging.
[3] Vincent J. Cunningham,et al. Parametric Imaging of Ligand-Receptor Binding in PET Using a Simplified Reference Region Model , 1997, NeuroImage.
[4] Jeih-San Liow,et al. Linearized Reference Tissue Parametric Imaging Methods: Application to [11C]DASB Positron Emission Tomography Studies of the Serotonin Transporter in Human Brain , 2003, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.
[5] M. Folstein,et al. Clinical diagnosis of Alzheimer's disease , 1984, Neurology.
[6] Ronald Boellaard,et al. Effects of reference tissue versus plasma input parametric kinetic modelling on statistical parametric analysis of [11C](R)-PK11195 binding in Alzheimer's disease (AD) and young and old subjects , 2005 .
[7] Roger N Gunn,et al. Positron Emission Tomography Compartmental Models: A Basis Pursuit Strategy for Kinetic Modeling , 2002, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.
[8] Eric Achten,et al. Assessment of Neuroinflammation and Microglial Activation in Alzheimer’s Disease with Radiolabelled PK11195 and Single Photon Emission Computed Tomography , 2003, European Neurology.
[9] G. Muehllehner,et al. Positron emission tomography , 2006, Physics in medicine and biology.
[10] Ronald Boellaard,et al. Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET , 2001, European Journal of Nuclear Medicine.
[11] Robert B. Innis,et al. Strategies to Improve Neuroreceptor Parameter Estimation by Linear Regression Analysis , 2002, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.
[12] David J. Schlyer,et al. Graphical Analysis of Reversible Radioligand Binding from Time—Activity Measurements Applied to [N-11C-Methyl]-(−)-Cocaine PET Studies in Human Subjects , 1990, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.
[13] Gert Luurtsema,et al. Optimizing an online SPE-HPLC method for analysis of (R)-[11C]1-(2-chlorophenyl)-N-methyl-N-(1-methylpropyl)-3-isoquinolinecarboxamide [(R)-[11C]PK11195] and its metabolites in humans. , 2005, Nuclear medicine and biology.
[14] F. Turkheimer,et al. Evidence of widespread cerebral microglial activation in amyotrophic lateral sclerosis: an [11C](R)-PK11195 positron emission tomography study , 2004, Neurobiology of Disease.
[15] Alexander Gerhard,et al. Evolution of microglial activation in patients after ischemic stroke: a [11C](R)-PK11195 PET study , 2005, NeuroImage.
[16] N. Volkow,et al. Distribution Volume Ratios without Blood Sampling from Graphical Analysis of PET Data , 1996, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.
[17] Gerald Q. Maguire,et al. Comparison and evaluation of retrospective intermodality brain image registration techniques. , 1997, Journal of computer assisted tomography.
[18] H. Kung,et al. Noninvasive quantification of dopamine D2 receptors with iodine-123-IBF SPECT. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[19] Roger N Gunn,et al. In-vivo measurement of activated microglia in dementia , 2001, The Lancet.
[20] Federico E. Turkheimer,et al. Imaging Activated Microglia in the Aging Human Brain , 2001 .
[21] F E Turkheimer,et al. [11C](R)-PK11195 positron emission tomography imaging of activated microglia in vivo in Rasmussen’s encephalitis , 1999, Neurology.
[22] Ronald Boellaard,et al. Development of a Tracer Kinetic Plasma Input Model for (R)-[11C]PK11195 Brain Studies , 2005, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.
[23] G. Kreutzberg. Microglia: a sensor for pathological events in the CNS , 1996, Trends in Neurosciences.
[24] Alexander Hammers,et al. In vivo imaging of microglial activation with [11C](R)-PK11195 PET in idiopathic Parkinson's disease , 2006, Neurobiology of Disease.
[25] M Slifstein,et al. Effects of statistical noise on graphic analysis of PET neuroreceptor studies. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[26] Alexander Gerhard,et al. In vivo imaging of microglial activation with [11C](R)‐PK11195 PET in corticobasal degeneration , 2004, Movement disorders : official journal of the Movement Disorder Society.
[27] Ronald Boellaard,et al. Optimization algorithms and weighting factors for analysis of dynamic PET studies , 2006, Physics in medicine and biology.
[28] R B Banati,et al. [11C](R)-PK11195 PET imaging of microglial activation in multiple system atrophy , 2003, Neurology.
[29] Elizabeth L Sampson,et al. In vivo detection of microglial activation in frontotemporal dementia , 2004, Annals of neurology.
[30] T D Cradduck,et al. National electrical manufacturers association , 1983, Journal of the A.I.E.E..
[31] Zsolt Cselényi,et al. A comparison of recent parametric neuroreceptor mapping approaches based on measurements with the high affinity PET radioligands [11C]FLB 457 and [11C]WAY 100635 , 2006, NeuroImage.
[32] R. Boellaard,et al. Assessment of microglial activation in mild cognitive impairment using [11C](R)-PK11195 and PET , 2006, NeuroImage.
[33] J Versijpt,et al. PET visualization of microglia in multiple sclerosis patients using [11C]PK11195 , 2003, European journal of neurology.
[34] R. Boellaard,et al. Evaluation of Reference Tissue Models for the Analysis of [11C](R)-PK11195 Studies , 2006, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.
[35] N L Foster,et al. PET of peripheral benzodiazepine binding sites in the microgliosis of Alzheimer's disease. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[36] L. Hartman,et al. MULTIMODALITY IMAGE REGISTRATION by PERSIS PRASAI , 2007 .
[37] Ronald Boellaard,et al. Data-driven volume of interest definition: Benefits and pitfalls , 2006, NeuroImage.
[38] A. Lammertsma,et al. Simplified Reference Tissue Model for PET Receptor Studies , 1996, NeuroImage.
[39] R B Banati,et al. Imaging cerebral vasculitis in refractory epilepsy using [(11)C](R)-PK11195 positron emission tomography. , 2001, AJR. American journal of roentgenology.
[40] S. Gunn,et al. Positron Emission Tomography Compartmental Models , 2001, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.
[41] R B Banati,et al. The peripheral benzodiazepine binding site in the brain in multiple sclerosis: quantitative in vivo imaging of microglia as a measure of disease activity. , 2000, Brain : a journal of neurology.
[42] T. Jones,et al. Spectral Analysis of Dynamic PET Studies , 1993, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.
[43] Richard E Carson,et al. Noise Reduction in the Simplified Reference Tissue Model for Neuroreceptor Functional Imaging , 2002, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.
[44] G Brix,et al. Performance evaluation of a whole-body PET scanner using the NEMA protocol. National Electrical Manufacturers Association. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[45] Guy Marchal,et al. Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.