Improved motion correction capabilities for fast spin echo T1 FLAIR propeller using non‐Cartesian external calibration data driven parallel imaging

Patient motion is a common challenge in the clinical setting and fast spin echo longitudinal relaxation time fluid attenuating inversion recovery imaging method with motion correction would be highly desirable. The motion correction provided by transverse relaxation time‐ and diffusion‐weighted periodically rotated overlapping parallel lines with enhanced reconstruction methods has seen significant clinical adoption. However, periodically rotated overlapping parallel lines with enhanced reconstruction with fast spin echo longitudinal relaxation time fluid attenuating inversion recovery‐weighting has proved challenging since motion correction requires wide blades that are difficult to acquire while also maintaining short echo train lengths that are optimal for longitudinal relaxation time fluid attenuating inversion recovery‐weighting. Parallel imaging provides an opportunity to increase the effective blade width for a given echo train lengths. Coil‐by‐coil data‐driven autocalibrated parallel imaging methods provide greater robustness in the event of motion compared to techniques relying on accurate coil sensitivity maps. However, conventional internally calibrated data‐driven parallel imaging methods limit the effective acceleration possible for each blade. We present a method to share a single calibration dataset over all imaging blades on a slice by slice basis using the APPEAR non‐Cartesian parallel imaging method providing an effective blade width increase of 2.45×, enabling robust motion correction. Results comparing the proposed technique to conventional Cartesian and periodically rotated overlapping parallel lines with enhanced reconstruction methods demonstrate a significant improvement during subject motion and maintaining high image quality when no motion is present in normal and clinical volunteers. Magn Reson Med, 2012. © 2012 Wiley Periodicals, Inc.

[1]  J. L. Duerk,et al.  Artifact Reduction in undersampled BLADE / PROPELLER MRI by k-space extrapolation using parallel imaging , 2005 .

[2]  Peter M. Jakob,et al.  Direct parallel imaging reconstruction of radially sampled data using GRAPPA with relative shifts , 2003 .

[3]  K. Arfanakis,et al.  k‐space undersampling in PROPELLER imaging , 2005, Magnetic resonance in medicine.

[4]  Stefan Skare,et al.  Clinical multishot DW‐EPI through parallel imaging with considerations of susceptibility, motion, and noise , 2007, Magnetic resonance in medicine.

[5]  Fred Tam,et al.  Retrospective coregistration of functional magnetic resonance imaging data using external monitoring , 2005, Magnetic resonance in medicine.

[6]  Oliver Speck,et al.  Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking system , 2006, NeuroImage.

[7]  Dwight G. Nishimura,et al.  Rapid gridding reconstruction with a minimal oversampling ratio , 2005, IEEE Transactions on Medical Imaging.

[8]  C. Jack,et al.  Prospective multiaxial motion correction for fMRI , 2000, Magnetic resonance in medicine.

[9]  Stefan Skare,et al.  An auto‐calibrated, angularly continuous, two‐dimensional GRAPPA kernel for propeller trajectories , 2008, Magnetic resonance in medicine.

[10]  Joseph V. Hajnal,et al.  High Signal Regions in Normal White Matter Shown by Heavily T2‐Weighted CSF Nulled IR Sequences , 1992, Journal of computer assisted tomography.

[11]  W. Bautz,et al.  Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient? , 2008, Academic radiology.

[12]  Joseph V. Hajnal,et al.  Use of Fluid Attenuated Inversion Recovery (FLAIR) Pulse Sequences in MRI of the Brain , 1992, Journal of computer assisted tomography.

[13]  Konstantinos Arfanakis,et al.  Motion correction in periodically‐rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and turboprop MRI , 2009, Magnetic resonance in medicine.

[14]  André J W van der Kouwe,et al.  Real‐time rigid body motion correction and shimming using cloverleaf navigators , 2006, Magnetic resonance in medicine.

[15]  S. Schoenberg,et al.  T1-Weighted Brain Imaging With a 32-Channel Coil at 3T Using TurboFLASH BLADE Compared With Standard Cartesian k-Space Sampling , 2009, Investigative radiology.

[16]  Zhiqiang Li,et al.  A parallel imaging technique using mutual calibration for split‐blade diffusion‐weighted PROPELLER , 2011, Magnetic resonance in medicine.

[17]  J. Pipe,et al.  Turboprop: Improved PROPELLER imaging , 2006, Magnetic resonance in medicine.

[18]  Clifford R. Jack,et al.  Spherical navigator echoes for full 3D rigid body motion measurement in MRI , 2001, SPIE Medical Imaging.

[19]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.

[20]  Val M. Runge,et al.  Brain Magnetic Resonance Imaging at 3 Tesla Using BLADE Compared With Standard Rectilinear Data Sampling , 2006, Investigative radiology.

[21]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[22]  K. Kwong,et al.  PROPELLER‐EPI with parallel imaging using a circularly symmetric phased‐array RF coil at 3.0 T: Application to high‐resolution diffusion tensor imaging , 2006, Magnetic resonance in medicine.

[23]  J. Pipe Motion correction with PROPELLER MRI: Application to head motion and free‐breathing cardiac imaging , 1999, Magnetic resonance in medicine.

[24]  Shingo Iwano,et al.  Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence , 2008, European Radiology.

[25]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.