Handheld photoacoustic probe to detect both melanoma depth and volume at high speed in vivo

We applied a linear-array-based photoacoustic probe to detect melanin-containing melanoma tumor depth and volume in nude mice in vivo. This system can image melanomas at five frames per second (fps), which is much faster than our previous handheld single transducer system (0.1 fps). We first theoretically show that, in addition to the higher frame rate, almost the entire boundary of the melanoma can be detected by the linear-array-based probe, while only the horizontal boundary could be detected by the previous system. Then we demonstrate the ability of this linear-array-based system in measuring both the depth and volume of melanoma through phantom, ex vivo, and in vivo experiments. The volume detection ability also enables us to accurately calculate the rate of growth of the tumor, which is an important parameter in quantifying the tumor activity. Our results show that this system can be used for clinical melanoma diagnosis and treatment in humans at the bedside. Linear-array-based PA images of melanoma acquired in vivo on day 3 (a) and day 6 (b).

[1]  W. Bergfeld,et al.  Inadequate biopsy technique and specimen size: an alarming trend that compromises patient care and an appeal to our clinical colleagues. , 2010, Archives of dermatology.

[2]  Konstantin I Maslov,et al.  Calibration-free in vivo transverse blood flowmetry based on cross correlation of slow time profiles from photoacoustic microscopy. , 2013, Optics letters.

[3]  A. Scott,et al.  Role of nuclear medicine in the management of cutaneous malignant melanoma. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  Konstantin I Maslov,et al.  Microcirculatory changes identified by photoacoustic microscopy in patients with complex regional pain syndrome type I after stellate ganglion blocks. , 2014, Journal of biomedical optics.

[5]  Zach DeVito,et al.  Opt , 2017 .

[6]  Rory Wolfe,et al.  The impact of partial biopsy on histopathologic diagnosis of cutaneous melanoma: experience of an Australian tertiary referral service. , 2010, Archives of dermatology.

[7]  Yong Zhou,et al.  Calibration-free absolute quantification of particle concentration by statistical analyses of photoacoustic signals in vivo , 2014, Journal of biomedical optics.

[8]  Milind Rajadhyaksha,et al.  Differences between polarized light dermoscopy and immersion contact dermoscopy for the evaluation of skin lesions. , 2007, Archives of dermatology.

[9]  Alistair P. Rendell,et al.  Modeling nonlinear ultrasound propagation in heterogeneous media with power law absorption using a k-space pseudospectral method. , 2012, The Journal of the Acoustical Society of America.

[10]  Lihong V Wang,et al.  Photoacoustic microscopy and computed tomography: from bench to bedside. , 2014, Annual review of biomedical engineering.

[11]  Rory Wolfe,et al.  Rate of growth in melanomas: characteristics and associations of rapidly growing melanomas. , 2006, Archives of dermatology.

[12]  Lihong V. Wang,et al.  Photoacoustic Tomography: In Vivo Imaging from Organelles to Organs , 2012, Science.

[13]  Lihong V. Wang Multiscale photoacoustic microscopy and computed tomography. , 2009, Nature photonics.

[14]  Bernard Querleux,et al.  Advances in MR imaging of the skin , 2006, NMR in biomedicine.

[15]  B T Cox,et al.  k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields. , 2010, Journal of biomedical optics.

[16]  A. Needles,et al.  Development and initial application of a fully integrated photoacoustic micro-ultrasound system , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[17]  Thilo Gambichler,et al.  Characterization of benign and malignant melanocytic skin lesions using optical coherence tomography in vivo. , 2007, Journal of the American Academy of Dermatology.

[18]  Sheila MacNeil,et al.  State of the art in non‐invasive imaging of cutaneous melanoma , 2011, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[19]  Konstantin I Maslov,et al.  Handheld photoacoustic microscopy to detect melanoma depth in vivo. , 2014, Optics letters.

[20]  Chiye Li,et al.  Slow-sound photoacoustic microscopy. , 2013, Applied physics letters.

[21]  Feng Gao,et al.  In vivo molecular photoacoustic tomography of melanomas targeted by bioconjugated gold nanocages. , 2010, ACS nano.

[22]  Junjie Yao,et al.  Optical clearing-aided photoacoustic microscopy with enhanced resolution and imaging depth. , 2013, Optics letters.

[23]  B. Bastian,et al.  Preoperative characterization of pigmented skin lesions by epiluminescence microscopy and high-frequency ultrasound. , 1995, Archives of dermatology.

[24]  A. Jemal,et al.  Recent trends in cutaneous melanoma incidence among whites in the United States. , 2001, Journal of the National Cancer Institute.

[25]  Yong Zhou,et al.  Photoacoustic microscopy of bilirubin in tissue phantoms , 2012, Journal of biomedical optics.

[26]  Lihong V. Wang,et al.  Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging , 2006, Nature Biotechnology.

[27]  Andrew G. Glen,et al.  APPL , 2001 .

[28]  J. Malvehy,et al.  Development of a two-step method for the diagnosis of melanoma by reflectance confocal microscopy. , 2009, Journal of the American Academy of Dermatology.

[29]  David A Barzilai,et al.  Evaluating invasive cutaneous melanoma: is the initial biopsy representative of the final depth? , 2003, Journal of the American Academy of Dermatology.