Practical reconstruction method for bioluminescence tomography.

Bioluminescence tomography (BLT) is used to localize and quantify bioluminescent sources in a small living animal. By advancing bioluminescent imaging to a tomographic framework, it helps to diagnose diseases, monitor therapies and facilitate drug development. In this paper, we establish a direct linear relationship between measured surface photon density and an unknown bioluminescence source distribution by using a finite-element method based on the diffusion approximation to the photon propagation in biological tissue. We develop a novel reconstruction algorithm to recover the source distribution. This algorithm incorporates a priori knowledge to define the permissible source region in order to enhance numerical stability and efficiency. Simulations with a numerical mouse chest phantom demonstrate the feasibility of the proposed BLT algorithm and reveal its performance in terms of source location, density, and robustness against noise. Lastly, BLT experiments are performed to identify the location and power of two light sources in a physical mouse chest phantom.

[1]  Allan F. Henry,et al.  Nuclear Reactor Analysis , 1977, IEEE Transactions on Nuclear Science.

[2]  Eva M Sevick-Muraca,et al.  Determination of optical properties in semi-infinite turbid media using imaging measurements of frequency-domain photon migration obtained with an intensified charge-coupled device. , 2004, Journal of biomedical optics.

[3]  S. Gambhir,et al.  Optical imaging of Renilla luciferase reporter gene expression in living mice , 2001, Proceedings of the National Academy of Sciences of the United States of America.

[4]  M. Kleiber,et al.  Selected Topics from the Mathematical Theory of Finite Elements , 1998 .

[5]  Vasilis Ntziachristos,et al.  Experimental fluorescence tomography of tissues with noncontact measurements , 2004, IEEE Transactions on Medical Imaging.

[6]  Yi Liu,et al.  A practical method to determine the light source distribution in bioluminescent imaging , 2004, SPIE Optics + Photonics.

[7]  S. Gambhir,et al.  Optical bioluminescence and positron emission tomography imaging of a novel fusion reporter gene in tumor xenografts of living mice. , 2003, Cancer research.

[8]  M. Schweiger,et al.  The finite element method for the propagation of light in scattering media: boundary and source conditions. , 1995, Medical physics.

[9]  Britton Chance,et al.  Diffuse optical tomography with a priori anatomical information , 2003, SPIE BiOS.

[10]  Singiresu S. Rao The finite element method in engineering , 1982 .

[11]  B. Rice,et al.  In vivo imaging of light-emitting probes. , 2001, Journal of biomedical optics.

[12]  M. Jiang,et al.  Uniqueness theorems in bioluminescence tomography. , 2004, Medical physics.

[13]  Hua-bei Jiang,et al.  Three-dimensional bioluminescence tomography with model-based reconstruction. , 2004, Optics express.

[14]  B. Wilson,et al.  A diffusion theory model of spatially resolved, steady-state diffuse reflectance for the noninvasive determination of tissue optical properties in vivo. , 1992, Medical physics.

[15]  Philip E. Gill,et al.  Practical optimization , 1981 .

[16]  Tongwen Chen,et al.  Digital Camera System Simulator and Applications , 2003 .

[17]  Vasilis Ntziachristos,et al.  The inverse source problem based on the radiative transfer equation in optical molecular imaging , 2005 .

[18]  Charles A. Bouman,et al.  Optical diffusion tomography by iterative- coordinate-descent optimization in a Bayesian framework , 1999 .