Accuracy in measurement of distance using limited cone-beam computerized tomography.

PURPOSE The purpose of this study was to evaluate the accuracy of measurement of distance on the images produced by limited cone-beam computerized tomography (CT). MATERIALS AND METHODS Five cadaver mandibles were examined by spiral computerized tomography (SCT) and limited cone-beam computerized tomography (LCBCT). The vertical distance from a reference point to the alveolar ridge was measured by caliper on the sliced mandible, and measurement error on the CT images was calculated in percentages based on the actual values and the measurement values obtained from the CT images. RESULTS Measurement error was determined to range from 0 to 1.11 mm (0% to 6.9%) on SCT and from 0.01 to 0.65 mm (0.1% to 5.2%) on LCBCT, with measurement errors of 2.2% and 1.4%, respectively (P < .0001). DISCUSSION This study suggests that distance can be measured accurately using LCBCT. The size of the rectangular solid images obtained using LCBCT (30 mm wide and 42.7 mm long) is thought to be adequate for observation of mandibular bony structure and for preoperative assessment before dental implant placement. CONCLUSION In this experiment on cadaver mandibles, LCBCT was shown to be a useful tool for preoperative evaluation in dental surgery because the relatively small field size of its images limits the patient's exposure to radiation.

[1]  T. Hosoi,et al.  Comparison of patient dose from imaging protocols for dental implant planning using conventional radiography and computed tomography. , 2001, Dento maxillo facial radiology.

[2]  A Petersson,et al.  Location of the mandibular canal: comparison of macroscopic findings, conventional radiography, and computed tomography. , 1989, The International journal of oral & maxillofacial implants.

[3]  M. Pharoah,et al.  Imaging techniques and image interpretation for dental implant treatment. , 1998, The International journal of prosthodontics.

[4]  A Ruprecht,et al.  Parameters of radiologic care: An official report of the American Academy of Oral and Maxillofacial Radiology. , 2001, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[5]  Y. Nakagawa,et al.  Preoperative application of limited cone beam computerized tomography as an assessment tool before minor oral surgery. , 2002, International journal of oral and maxillofacial surgery.

[6]  E. Ariji,et al.  Cross-sectional imaging of the jaws for dental implant treatment: accuracy of linear tomography using a panoramic machine in comparison with reformatted computed tomography. , 2002, The International journal of oral & maxillofacial implants.

[7]  K Shinoda,et al.  Clinical application of a new compact CT system to assess 3-D images for the preoperative treatment planning of implants in the posterior mandible A case report. , 2001, Clinical oral implants research.

[8]  E Tammisalo,et al.  Development of a compact computed tomographic apparatus for dental use. , 1999, Dento maxillo facial radiology.