Damage event analysis of vertical ground source heat pump systems in Germany

In recent years, some spectacular cases of damage occurred with vertical ground source heat pump (GSHP) systems in Germany. Broad media coverage attracted enormous public attention, with reports about land subsidence and ground uplifts causing severe damage to buildings. Consequently, sales of vertical GSHP systems have declined. The current study develops conceptual models illustrating the causes and effects of damage in relation to geological and hydrogeological settings. Our investigations revealed nine cases of serious damage in Germany, causing financial losses of more than 100 million Euros. In most cases, connection of aquifers by leaky annular space grouting was the main cause of damage. Guidelines to regulate the installation of vertical GSHP systems have been introduced successfully in all federal states. However, further risk minimisation strategies must be developed to restore the public’s confidence in GSHP technology. Quality assurance and quality control measures should include in particular the optimisation of backfilling materials and increasing use of monitoring systems.

[1]  G. Wirsing,et al.  Erkundung und Sanierungsstrategien im Erdwärmesonden‐Schadensfall Staufen i. Br. , 2013 .

[2]  P. Blum,et al.  Schadensfallanalyse von Erdwärmesondenbohrungen in Baden-Württemberg , 2014, Grundwasser.

[3]  Philipp Blum,et al.  Techno-economic and spatial analysis of vertical ground source heat pump systems in Germany , 2011 .

[4]  Jamie L. Martens,et al.  Investigating cross-contamination of aquifers , 2006 .

[5]  Peter Huggenberger,et al.  Risikoorientierte Bewilligung von Erdwärmesonden , 2011 .

[6]  Andreas Kappler,et al.  Biodegradability and groundwater pollutant potential of organic anti-freeze liquids used in borehole heat exchangers , 2007 .

[7]  Pradeep K. Sahoo,et al.  Potential Reduction in CO2 Emission and Saving in Electricity by Ground Source Heat Pump System for Space Heating Applications - A Study on Northern Part of India , 2012 .

[8]  Peter Bayer,et al.  Oberflächennahe Geothermie und ihre potenziellen Auswirkungen auf Grundwasserökosysteme , 2011 .

[9]  Philipp Blum,et al.  Sustainability and policy for the thermal use of shallow geothermal energy , 2013 .

[10]  Christoph Butscher,et al.  Swelling laws for clay-sulfate rocks revisited , 2018, Bulletin of Engineering Geology and the Environment.

[11]  U. Burbaum,et al.  Geothermische Bohrungen in Staufen im Breisgau: Schadensursachen und Perspektiven , 2012 .

[12]  Ingo Sass,et al.  Damage to the historic town of Staufen (Germany) caused by geothermal drillings through anhydrite-bearing formations , 2010 .

[13]  Peter Bayer,et al.  Oberflächennahe Geothermie – aktuelle rechtliche Situation in Deutschland , 2011 .

[14]  Thomas Kölbel,et al.  CO2 savings of ground source heat pump systems – A regional analysis , 2010 .

[15]  Christoph Butscher,et al.  Swelling of Clay-Sulfate Rocks: A Review of Processes and Controls , 2016, Rock Mechanics and Rock Engineering.

[16]  Joris Ondreka,et al.  GIS-supported mapping of shallow geothermal potential of representative areas in south-western Germany—Possibilities and limitations , 2007 .

[17]  Philipp Blum,et al.  Greenhouse gas emission savings of ground source heat pump systems in Europe: A review , 2012 .

[18]  N. Goldscheider,et al.  Editors’ message: The housing crisis from underground—damage to a historic town by geothermal drillings through anhydrite, Staufen, Germany , 2009 .

[19]  The Energy-Water Nexus Underground Thermal Energy Storage : Environmental Risks and Policy Developments in the Netherlands and European Union , 2011 .