Venous cannula performance assessment in a realistic caval tree model.

OBJECTIVES A new caval tree system was designed for realistic in vitro simulation. The objective of our study was to assess cannula performance for virtually wall-less versus standard percutaneous thin-walled venous cannulas in a setting of venous collapse in case of negative pressure. METHODS For a collapsible caval model, a very flexible plastic material was selected, and a model with nine afferent veins was designed according to the anatomy of the vena cava. A flow bench was built including a lower reservoir holding the caval tree, built by taking into account the main afferent vessels and their flow provided by a reservoir 6 cm above. A cannula was inserted in this caval tree and connected to a centrifugal pump that, in turn, was connected to a reservoir positioned 83 cm above the second lower reservoir (after-load = 60 mmHg). Using the same pre-load, the simulated venous drainage for cardiopulmonary bypass was realized using a 24 F wall-less cannula (Smartcanula) and 25 F percutaneous cannula (Biomedicus), and stepwise increased augmentation (1500 RPM, 2000 and 2500 RPM) of venous drainage. RESULTS For the thin wall and the wall-less cannulas, 36 pairs of flow and pressure measurements were realized for three different RPM values. The mean Q-values at 1500, 2000 and 2500 RPM were: 3.98 ± 0.01, 6.27 ± 0.02 and 9.81 ± 0.02 l/min for the wall-less cannula (P <0.0001), versus 2.74 ± 0.02, 3.06 ± 0.05, 6.78 ± 0.02 l/min for the thin-wall cannula (P <0.0001). The corresponding inlet pressure values were: -8.88 ± 0.01, -23.69 ± 0.81 and -70.22 ± 0.18 mmHg for the wall-less cannula (P <0.0001), versus -36.69 ± 1.88, -80.85 ± 1.71 and -101.83 ± 0.45 mmHg for the thin-wall cannula (P <0.0001). The thin-wall cannula showed mean Q-values 37% less and mean P values 26% more when compared with the wall-less cannula (P <0.0001). CONCLUSIONS Our in vitro water test was able to mimic a negative pressure situation, where the wall-less cannula design performs better compared with the traditional thin-wall cannula.

[1]  D. Berdajs,et al.  Caval collapse during cardiopulmonary bypass: a reproducible bench model. , 2014, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[2]  D. Berdajs,et al.  Superior venous drainage in the “LifeBox”: a portable extracorporeal oxygenator with a self-expanding venous cannula , 2010, Perfusion.

[3]  L. V. von Segesser,et al.  Superior flow for bridge to life with self-expanding venous cannulas. , 2009, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[4]  L. V. von Segesser,et al.  Temporary caval stenting improves venous drainage during cardiopulmonary bypass. , 2008, Interactive cardiovascular and thoracic surgery.

[5]  L. V. von Segesser,et al.  Bridge to Life: The Lifebridge B2T® extracorporeal life support system in an in vitro trial , 2008, Perfusion.

[6]  L. V. von Segesser,et al.  Routine use of self-expanding venous cannulas for cardiopulmonary bypass: benefits and pitfalls in 100 consecutive cases. , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[7]  L. V. von Segesser,et al.  New bench test for venous cannula performance assessment , 2007, Perfusion.

[8]  L. K. Segesser,et al.  Herzentlastung mittels EKZ vor der Resternotomie , 2007, Zeitschrift für Herz-,Thorax- und Gefäßchirurgie.

[9]  A. Corno Systemic venous drainage: can we help Newton? , 2007, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[10]  J. Maessen,et al.  An in vitro and in vivo study of the detection and reversal of venous collapse during extracorporeal life support. , 2007, Artificial organs.

[11]  M. Wilbring,et al.  Koronarchirurgie bei Patienten mit dialysepflichtiger terminaler Niereninsuffizienz , 2007, Zeitschrift für Herz-,Thorax- und Gefäßchirurgie.

[12]  J. Maessen,et al.  Synchronously counterpulsating extracorporeal life support enhances myocardial working conditions regardless of systemic perfusion pressure. , 2005, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[13]  L. V. von Segesser,et al.  The Smartcanula: a new tool for remote access perfusion in limited access cardiac surgery. , 2005, The heart surgery forum.

[14]  L. V. von Segesser,et al.  Limitations using the vacuum-assist venous drainage technique during cardiopulmonary bypass procedures. , 2003, The journal of extra-corporeal technology.

[15]  R. Ohye,et al.  Use of extracorporeal life support as a bridge to pediatric cardiac transplantation. , 2003, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[16]  L. V. von Segesser,et al.  A new expandable venous cannula for minimal access heart surgery. , 2002, The Annals of thoracic surgery.

[17]  L. V. von Segesser,et al.  Optimized venous return with a self-expanding cannula: from computational fluid dynamics to clinical application. , 2002, Interactive cardiovascular and thoracic surgery.

[18]  L. V. von Segesser,et al.  Optimization of venous return tubing diameter for cardiopulmonary bypass. , 2001, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[19]  Gary K. Fisk Bridge to Life , 2000 .

[20]  M. Amino,et al.  Clinical experience of a vacuum-assisted nonroller extra-corporeal circulation system. , 2000, The journal of extra-corporeal technology.

[21]  J. Younger,et al.  Extracorporeal life support: the University of Michigan experience. , 2000, JAMA.

[22]  L. V. von Segesser,et al.  Optimization of the Pump Driven Venous Return for Minimally Invasive Open Heart Surgery , 1999, The International journal of artificial organs.

[23]  L. Segesser Cardiopulmonary support and extracorporeal membrane oxygenation for cardiac assist , 1999 .

[24]  J. Toomasian,et al.  Total extrathoracic cardiopulmonary support with kinetic assisted venous drainage: experience in 50 patients , 1998, Perfusion.

[25]  W. Santamore,et al.  Venous collapse and the respiratory variability in systemic venous return. , 1994, Cardiovascular Research.

[26]  D. Hoffman,et al.  High-flow femoro-femoral bypass utilizing small cannulae and a centrifugal pump on the venous side , 1992, Perfusion.