Pilot study of closing volume in byssinosis.

A study of the relative sensitivities of forced expiratory volume in one second (FEV1), maximal mid-expiratory flow (MMF), and closing volume (CV) in the detection of subjects with byssinosis was carried out in a North Carolina cotton mill. Altogether 35 workers participated in the study. Of these, nine showed a decline in FEV1 of 10% or more during the first work shift that followed the weekend break. Twelve subjects showed a decrease in MMF of 15% or more. In contrast only six workers exhibited a 10% increase in closing capacity, while ten showed a 10% increase in CV. Recent evidence of the magnitude of variability in closing volume manoeuvres suggests that our chosen level of change was too low, A 40% change in CV would have identified only five subjects. CV is a more complex manoeuvre for the subject being tested and for the technician to perform, is more time consuming, and is subject to greater variation. To have any advantage over spirometry, CV would have to be appreciably more sensitive. Our study suggests that it is not. However, the MMF may prove to be more sensitive than the FEV1 in the detection of byssinosis.

[1]  W. Morgan,et al.  Closing volume in coal miners. , 1976, The American review of respiratory disease.

[2]  E. R. Mcfadden,et al.  Variability of closing volume measurements in normal man. , 1975, The American review of respiratory disease.

[3]  E. R. Mcfadden,et al.  Small airway disease: An assessment of the tests of peripheral airway function , 1974 .

[4]  A. Buist,et al.  Early detection of airways obstruction by the closing volume technique. , 1973, Chest.

[5]  J Milic-Emili,et al.  Measurement of "closing volume" as a simple and sensitive test for early detection of small airway disease. , 1972, The American journal of medicine.

[6]  J. Hankinson,et al.  Changes in ventilatory function in coal miners after a work shift. , 1972, Archives of environmental health.

[7]  E. Žuškin,et al.  Byssinosis in carding and spinning workers. Prevalence in the cotton textile industry. , 1969, Archives of environmental health.

[8]  E. Gubéran,et al.  Circadian variation of F.E.V. in shift workers , 1969, British journal of industrial medicine.

[9]  R. Schilling,et al.  Diurnal Variation in Ventilatory Capacity: An Epidemiological Study of Cotton and other Factory Workers employed on Shift Work , 1966, British journal of industrial medicine.

[10]  S. A. Roach,et al.  A Clinical and Environmental Study of Byssinosis in the Lancashire Cotton Industry , 1960, British journal of industrial medicine.

[11]  Leuallen Ec,et al.  Maximal midexpiratory flow. , 1955 .

[12]  D. McCarthy,et al.  Closing volume in asymptomatic asthma. , 1973, The American review of respiratory disease.

[13]  T. Clark,et al.  Closing volume in healthy non-smokers. , 1973, British journal of diseases of the chest.

[14]  D. C. Braun,et al.  Prevalence of respiratory signs and symptoms among U.S. cotton textile workers. , 1973, Journal of Occupational Medicine.

[15]  W. S. Fowler,et al.  Maximal midexpiratory flow. , 1955, American review of tuberculosis.