3D Simulation Analysis of Central Shunt in Patient-Specific Hemodynamics: Effects of Varying Degree of Pulmonary Artery Stenosis and Shunt Diameters

The objective of this study was to compare the effects of different shunt diameters and pulmonary artery (PA) stenosis grades on the hemodynamics of central shunts to determine an optimal surgical plan and improve the long-term outcomes of the operation. A 3D anatomical model was reconstructed based on the patient's clinical CT data. 3D computational fluid dynamics models were built with varying degrees of stenosis (the stenosis ratio α was represented by the ratio of blood flow through the main pulmonary artery to cardiac output, ranging from 0 to 30%; the smaller the value of α, the more severe the pulmonary artery stenosis) and varying shunt diameters (3, 3.5, 4, 4.5, and 5 mm). Our results show that the asymmetry of pulmonary artery flow increased with increasing shunt diameter and α, which will be more conducive to the development of the left pulmonary artery. Additionally, the pulmonary-to-systemic flow ratio (QP/QS) increases with the shunt diameter and α, and all the values exceed 1. When the shunt diameter is 3 mm and α = 0%, QP/QS reaches the minimum value of 1.01, and the oxygen delivery reaches the maximum value of 205.19 ml/min. However, increasing shunt diameter and α is beneficial to reduced power loss and smoother PA flow. In short, for patients with severe PA stenosis (α is small), a larger-diameter shunt may be preferred. Conversely, when the degree of PA stenosis is moderate, a smaller shunt diameter can be considered.

[1]  G B Fiore,et al.  In vitro steady-flow analysis of systemic-to-pulmonary shunt haemodynamics. , 2001, Journal of biomechanics.

[2]  A. Yoganathan,et al.  Energetic implications of vessel growth and flow changes over time in Fontan patients. , 2015, The Annals of thoracic surgery.

[3]  Guanghong Ding,et al.  Numerical Investigation of the Effect of Additional Pulmonary Blood Flow on Patient-Specific Bilateral Bidirectional Glenn Hemodynamics , 2018, Cardiovascular Engineering and Technology.

[4]  S. Alper,et al.  Hemodynamic shear stress and its role in atherosclerosis. , 1999, JAMA.

[5]  Kerem Pekkan,et al.  Hemodynamics of patient-specific aorta-pulmonary shunt configurations. , 2017, Journal of biomechanics.

[6]  Xiangyu Chen,et al.  Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation , 2019, Comput. Math. Methods Medicine.

[7]  Gianfranco Ferrari,et al.  Hemodynamic Effects of Ventricular Assist Device Implantation on Norwood, Glenn, and Fontan Circulation: A Simulation Study. , 2016, Artificial organs.

[8]  Gavin A. D’Souza,et al.  Evaluation of pulmonary artery stenosis in congenital heart disease patients using functional diagnostic parameters: An in vitro study. , 2018, Journal of biomechanics.

[9]  M. Bojan,et al.  Bidirectional cavopulmonary shunt with additional pulmonary blood flow: a failed or successful strategy? , 2012, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[10]  J. Rychik,et al.  Assessment of pulmonary/systemic blood flow ratio after first-stage palliation for hypoplastic left heart syndrome: development of a new index with the use of doppler echocardiography. , 2000, The Journal of thoracic and cardiovascular surgery.

[11]  Ali Cemal Benim,et al.  Modelling turbulent flow past a circular cylinder by RANS, URANS, LES and DES , 2008 .

[12]  A. Yoganathan,et al.  Effect of Fontan geometry on exercise haemodynamics and its potential implications , 2017, Heart.

[13]  A. Yoganathan,et al.  Exercise capacity in single-ventricle patients after Fontan correlates with haemodynamic energy loss in TCPC , 2014, Heart.

[14]  F. Migliavacca,et al.  Multiscale modelling in biofluidynamics: application to reconstructive paediatric cardiac surgery. , 2006, Journal of biomechanics.

[15]  Laszlo Fuchs,et al.  Wall shear stress variations in a 90-degree bifurcation in 3D pulsating flows. , 2010, Medical engineering & physics.

[16]  O Barnea,et al.  Estimation of oxygen delivery in newborns with a univentricular circulation. , 1998, Circulation.

[17]  Tain-Yen Hsia,et al.  Simulations reveal adverse hemodynamics in patients with multiple systemic to pulmonary shunts. , 2015, Journal of biomechanical engineering.

[18]  F. Migliavacca,et al.  The influence of systemic-to-pulmonary arterial shunts and peripheral vasculatures in univentricular circulations: Focus on coronary perfusion and aortic arch hemodynamics through computational multi-domain modeling. , 2018, Journal of biomechanics.

[19]  A. Kassab,et al.  Patient-Specific Multi-Scale Model Analysis of Hemodynamics Following the Hybrid Norwood Procedure for Hypoplastic Left Heart Syndrome: Effects of Reverse Blalock–Taussig Shunt Diameter , 2018, Cardiovascular Engineering and Technology.

[20]  F. Migliavacca,et al.  Multiscale modeling of the cardiovascular system: application to the study of pulmonary and coronary perfusions in the univentricular circulation. , 2005, Journal of biomechanics.

[21]  D. Ku,et al.  Optimal graft diameter: effect of wall shear stress on vascular healing. , 1989, Journal of vascular surgery.

[22]  Lakshmi P. Dasi,et al.  Hemodynamic Energy Dissipation in the Cardiovascular System: Generalized Theoretical Analysis on Disease States , 2008, Annals of Biomedical Engineering.

[23]  A. Yoganathan,et al.  Fontan hemodynamics from 100 patient-specific cardiac magnetic resonance studies: a computational fluid dynamics analysis. , 2014, The Journal of thoracic and cardiovascular surgery.

[24]  N. Nichay,et al.  Bidirectional cavopulmonary anastomosis with additional pulmonary blood flow: good or bad pre-Fontan strategy. , 2017, Interactive cardiovascular and thoracic surgery.

[25]  N. Bressloff,et al.  Turbulence modeling in three-dimensional stenosed arterial bifurcations. , 2007, Journal of biomechanical engineering.

[26]  B. Meyns,et al.  In Vitro Set-Up of Modified Blalock Taussig Shunt: Vascular Resistance-Flow Relationship , 2006, The International journal of artificial organs.

[27]  D. Barron,et al.  Risk assessment and early outcome following the Norwood procedure for hypoplastic left heart syndrome. , 2006, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[28]  Ali Cemal Benim,et al.  Simulation of blood flow in human aorta with emphasis on outlet boundary conditions , 2011 .

[29]  A. Yoganathan,et al.  Nonlinear Power Loss During Exercise in Single-Ventricle Patients After the Fontan: Insights From Computational Fluid Dynamics , 2007, Circulation.

[30]  D. McElhinney,et al.  Fetal model of single ventricle physiology: hemodynamic effects of oxygen, nitric oxide, carbon dioxide, and hypoxia in the early postnatal period. , 1996, The Journal of thoracic and cardiovascular surgery.

[31]  T. Spray,et al.  Surgical approach to hyploplastic left heart syndrome - Norwood Stage I. , 2007, Multimedia manual of cardiothoracic surgery : MMCTS.

[32]  F. Migliavacca,et al.  Modeling of the Norwood circulation: effects of shunt size, vascular resistances, and heart rate. , 2001, American journal of physiology. Heart and circulatory physiology.

[33]  Y. Chatzizisis,et al.  Non-Newtonian models for molecular viscosity and wall shear stress in a 3D reconstructed human left coronary artery. , 2008, Medical engineering & physics.

[34]  W. Santamore,et al.  Effects of oxygen, positive end-expiratory pressure, and carbon dioxide on oxygen delivery in an animal model of the univentricular heart. , 1996, The Journal of thoracic and cardiovascular surgery.

[35]  W. Santamore,et al.  Inotropes in the hypoplastic left heart syndrome: effects in an animal model. , 1996, The Annals of thoracic surgery.

[36]  O Barnea,et al.  Balancing the circulation: theoretic optimization of pulmonary/systemic flow ratio in hypoplastic left heart syndrome. , 1994, Journal of the American College of Cardiology.