Holographic microwave imaging for medical applications

This paper presents a new 2D holographic microwave imaging array (HMIA) technique for medical imaging applications. The HMIA technique has been applied to early stage breast cancer detection and brain stroke detection. Computer models are developed to demonstrate the feasibility of detecting and localizing small brain strokes within a 2D numerical head model and breast tumours within a 3D numerical breast model using the HMIA technique. Experimental validation of the HMIA simulation model using a breast phantom has been undertaken and demonstrated a good agreement between experimental and simulated images. Simulation and experimental results showed that the proposed HMIA technique has the potential to become a powerful medical screening and diagnostic tool.

[1]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[2]  A. Taflove,et al.  Two-dimensional FDTD analysis of a pulsed microwave confocal system for breast cancer detection: fixed-focus and antenna-array sensors , 1998, IEEE Transactions on Biomedical Engineering.

[3]  Amin M. Abbosh,et al.  Compact wideband antenna immerssed in optimum coupling liquid for microwave imaging of brain stroke , 2012 .

[4]  C. Gabriel Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies. , 1996 .

[5]  X. Li,et al.  Confocal microwave imaging for breast cancer detection: localization of tumors in three dimensions , 2002, IEEE Transactions on Biomedical Engineering.

[6]  R. Hendrick,et al.  Imaging of the radiographically dense breast. , 1993, Radiology.

[7]  D. Malacara-Hernández,et al.  PRINCIPLES OF OPTICS , 2011 .

[8]  J. Richmond Scattering by a dielectric cylinder of arbitrary cross section shape , 1965 .

[9]  S. S. Chaudhary,et al.  Dielectric properties of normal & malignant human breast tissues at radiowave & microwave frequencies. , 1984, Indian journal of biochemistry & biophysics.

[10]  Amin M. Abbosh,et al.  Wideband antenna for microwave imaging of brain , 2011, 2011 Seventh International Conference on Intelligent Sensors, Sensor Networks and Information Processing.

[11]  A. Al-Jumaily,et al.  Holographic Microwave Imaging Array for Brain Stroke Detection , 2013 .

[12]  E. Fear Microwave Imaging of the Breast , 2005, Technology in cancer research & treatment.

[13]  W. Joines,et al.  The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz. , 1994, Medical physics.

[14]  P. Kosmas,et al.  Time reversal with the FDTD method for microwave breast cancer detection , 2005, IEEE Transactions on Microwave Theory and Techniques.

[15]  Shireen D. Geimer,et al.  Microwave image reconstruction from 3-D fields coupled to 2-D parameter estimation , 2004, IEEE Transactions on Medical Imaging.

[16]  Ian J Craddock,et al.  Microwave Radar-Based Differential Breast Cancer Imaging: Imaging in Homogeneous Breast Phantoms and Low Contrast Scenarios , 2010, IEEE Transactions on Antennas and Propagation.

[17]  Laura W. Bancroft,et al.  Imaging in Acute Stroke , 2011, The western journal of emergency medicine.

[18]  Marek Bialkowski,et al.  Feasibility study on microwave stroke detection using a realistic phantom and the FDTD method , 2010, 2010 Asia-Pacific Microwave Conference.

[19]  Lorenzo Crocco,et al.  A FEASIBILITY STUDY ON MICROWAVE IMAGING FOR BRAIN STROKE MONITORING , 2012 .

[20]  Roger F. Harrington,et al.  Field computation by moment methods , 1968 .

[21]  Elise C. Fear,et al.  Microwave detection of breast cancer: a study of tumor response variations , 2000, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143).

[22]  Ji Zhenyu,et al.  Breast Cancer Detection Based on Multi-Frequency EIS Measurement , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[23]  L. G. Hector,et al.  The Dielectric Constant of Air at Radiofrequencies , 1936 .

[24]  Mark D. Huffman,et al.  Heart disease and stroke statistics--2013 update: a report from the American Heart Association. , 2013, Circulation.

[25]  M. Ravan,et al.  Three-Dimensional Near-Field Microwave Holography Using Reflected and Transmitted Signals , 2011, IEEE Transactions on Antennas and Propagation.

[26]  D. Smith,et al.  Indirect Holographic Techniques for Determining Antenna Radiation Characteristics and Imaging Aperture Fields , 2007, IEEE Antennas and Propagation Magazine.

[27]  T. Rubaek,et al.  Computational Validation of a 3-D Microwave Imaging System for Breast-Cancer Screening , 2009, IEEE Transactions on Antennas and Propagation.

[28]  N. Nikolova,et al.  Two-dimensional near-field microwave holography , 2010 .

[29]  D. Corfield,et al.  Microwave Tomography for Brain Imaging: Feasibility Assessment for Stroke Detection , 2008 .

[30]  S.C. Hagness,et al.  A confocal microwave imaging algorithm for breast cancer detection , 2001, IEEE Microwave and Wireless Components Letters.

[31]  E A Sickles,et al.  Screening mammography in community practice: positive predictive value of abnormal findings and yield of follow-up diagnostic procedures. , 1995, AJR. American journal of roentgenology.

[32]  J. Hornaday,et al.  Cancer Facts & Figures 2004 , 2004 .

[33]  Zhang,et al.  An Overview of Active Microwave Imaging for Early Breast Cancer Detection , 2010 .

[34]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[35]  S. Silver Microwave antenna theory and design , 1949 .

[36]  O. Baltag,et al.  MICROWAVE THERMOGRAPHY FOR CANCER DETECTION , 2006 .

[37]  Lulu Wang,et al.  3D breast cancer imaging using holographic microwave interferometry , 2012, IVCNZ '12.

[38]  W. Welford Principles of optics (5th Edition): M. Born, E. Wolf Pergamon Press, Oxford, 1975, pp xxviii + 808, £9.50 , 1975 .

[39]  Stuchly,et al.  Dielectric properties of breast carcinoma and the surrounding tissues , 1988, IEEE Transactions on Biomedical Engineering.

[40]  M. Persson,et al.  Antenna array design for brain monitoring , 2008, 2008 IEEE Antennas and Propagation Society International Symposium.

[41]  W. P. Evans,et al.  American Cancer Society Guidelines for Breast Cancer Screening: Update 2003 , 2003, CA: a cancer journal for clinicians.

[42]  Paul M. Meaney,et al.  Enhancing breast tumor detection with near-field imaging , 2002 .