Optimization of Hydrogen Peroxide Detection for a Methyl Mercaptan Biosensor

Several kinds of modified carbon screen printed electrodes (CSPEs) for amperometric detection of hydrogen peroxide (H2O2) are presented in order to propose a methyl mercaptan (MM) biosensor. Unmodified, carbon nanotubes (CNTs), cobalt phthalocyanine (CoPC), Prussian blue (PB), and Os-wired HRP modified CSPE sensors were fabricated and tested to detect H2O2, applying a potential of +0.6 V, +0.6 V, +0.4 V, −0.2 V and −0.1 V (versus Ag/AgCl), respectively. The limits of detection of these electrodes for H2O2 were 3.1 μM, 1.3 μM, 71 nM, 1.3 μM, 13.7 nM, respectively. The results demonstrated that the Os-wired HRP modified CSPEs gives the lowest limit of detection (LOD) for H2O2 at a working potential as low as −0.1 V. Os-wired HRP is the optimum choice for establishment of a MM biosensor and gives a detection limit of 0.5 μM.

[1]  J. P. Dijken,et al.  Methyl mercaptan oxidase, a key enzyme in the metabolism of methylated sulphur compounds by Hyphomicrobium EG , 1987 .

[2]  M. Pumera,et al.  Carbon nanotubes can exhibit negative effects in electroanalysis due to presence of nanographite impurities , 2011 .

[3]  P. Tuñón,et al.  Electrocatalytic detection of nicotinamide coenzymes by poly(o-aminophenol)- and poly(o-phenylenediamine)-modified carbon paste electrodes , 1996 .

[4]  Yuehe Lin,et al.  Solubilization of carbon nanotubes by Nafion toward the preparation of amperometric biosensors. , 2003, Journal of the American Chemical Society.

[5]  Brian J. Birch,et al.  Development of amperometric sensors for uric acid based on chemically modified graphite-epoxy resin and screen-printed electrodes containing cobalt phthalocyanine , 1994 .

[6]  H. Saito,et al.  Bioelectronic sniffer with monoamine oxidase for methyl mercaptan vapor , 2005 .

[7]  F Ricci,et al.  Sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes. , 2005, Biosensors & bioelectronics.

[8]  R. Murray,et al.  Electron diffusion in wet and dry Prussian blue films on interdigitated array electrodes , 1987 .

[9]  N. F. Sheppard Biosensor principles and applications. , 1992, Bioprocess technology.

[10]  Hiroyuki Kudo,et al.  Optical bio-sniffer for methyl mercaptan in halitosis. , 2006, Analytica chimica acta.

[11]  Joseph Wang,et al.  Carbon nanotube/teflon composite electrochemical sensors and biosensors. , 2003, Analytical chemistry.

[12]  J. Tonzetich,et al.  Production of volatile sulphur compounds from cysteine, cystine and methionine by human dental plague. , 1971, Archives of oral biology.

[13]  J Tonzetich,et al.  Production and origin of oral malodor: a review of mechanisms and methods of analysis. , 1977, Journal of periodontology.

[14]  M. Kwiatkowski,et al.  Evolution of 3-mercaptohexanol, hydrogen sulfide, and methyl mercaptan during bottle storage of Sauvignon blanc wines. Effect of glutathione, copper, oxygen exposure, and closure-derived oxygen. , 2011, Journal of agricultural and food chemistry.

[15]  Pier Giorgio Zambonin,et al.  Ascorbic acid interferences in hydrogen peroxide detecting biosensors based on electrochemically immobilized enzymes , 1993 .

[16]  Michael Holzinger,et al.  Enhanced Direct Electron Transfer of a Multihemic Nitrite Reductase on Single-walled Carbon Nanotube Modified Electrodes , 2010 .

[17]  A. Heller,et al.  Hydrogen peroxide and .beta.-nicotinamide adenine dinucleotide sensing amperometric electrodes based on electrical connection of horseradish peroxidase redox centers to electrodes through a three-dimensional electron relaying polymer network , 1992 .

[18]  G. Palleschi,et al.  A study of interferences in glucose measurements in blood by hydrogen peroxide based glucose probes. , 1986, Analytical biochemistry.

[19]  P. L. Kirk,et al.  Determination of Fatty Acids by Potentiometric Titration , 1953 .

[20]  T. Hamasaki,et al.  The assessment of methyl mercaptan, an important clinical marker for the diagnosis of oral malodor. , 2004, Journal of dentistry.

[21]  K. Mitsubayashi,et al.  Bioelectronic nose for methyl mercaptan vapor using xenobiotic metabolizing enzyme: flavin-containing monooxygenase , 2002 .

[22]  F. Ricci,et al.  Prussian Blue based screen printed biosensors with improved characteristics of long-term lifetime and pH stability. , 2003, Biosensors & bioelectronics.

[23]  Danila Moscone,et al.  Prussian Blue and enzyme bulk-modified screen-printed electrodes for hydrogen peroxide and glucose determination with improved storage and operational stability , 2003 .

[24]  Marek Trojanowicz,et al.  Analytical applications of carbon nanotubes : a review , 2006 .

[25]  N. Jaffrezic‐Renault,et al.  Bioelectronic detector with monoamine oxidase for halitosis monitoring. , 2005, The Analyst.

[26]  Joseph Wang Carbon‐Nanotube Based Electrochemical Biosensors: A Review , 2005 .

[27]  A. Michael,et al.  Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymer. , 1993, Analytical chemistry.

[28]  F. Braet,et al.  Carbon Nanomaterials in Biosensors: Should You Use Nanotubes or Graphene? , 2010 .

[29]  Richard G Compton,et al.  Iron oxide particles are the active sites for hydrogen peroxide sensing at multiwalled carbon nanotube modified electrodes. , 2006, Nano letters.

[30]  Richard J. Ewen,et al.  Voltammetric and photoelectron spectral elucidation of the electrocatalytic oxidation of hydrogen peroxide at screen-printed carbon electrodes chemically modified with cobalt phthalocyanine , 1995 .

[31]  A. Salimi,et al.  Nanomolar detection of hydrogen peroxide on glassy carbon electrode modified with electrodeposited cobalt oxide nanoparticles. , 2007, Analytica chimica acta.

[32]  M Rosenberg,et al.  Reproducibility and Sensitivity of Oral Malodor Measurements with a Portable Sulphide Monitor , 1991, Journal of dental research.

[33]  L. Gorton,et al.  Electrochemical behavior and application of Prussian blue nanoparticle modified graphite electrode , 2010 .

[34]  K. Kano,et al.  Highly-sensitive flow injection determination of hydrogen peroxide with a peroxidase-immobilized electrode and its application to clinical chemistry , 2000 .

[35]  A. Guenther,et al.  Sulfur emissions to the atmosphere from natural sourees , 1992 .

[36]  D. Stilwell,et al.  Electrochemical studies of the factors influencing the cycle stability of Prussian Blue films , 1992 .

[37]  Richard G Compton,et al.  Carbon nanotubes contain metal impurities which are responsible for the "electrocatalysis" seen at some nanotube-modified electrodes. , 2006, Angewandte Chemie.

[38]  T. Golden,et al.  Cobalt phthalocyanine/cellulose acetate chemically modified electrodes for electrochemical detection in flowing streams. Multifunctional operation based upon the coupling of electrocatalysis and permselectivity. , 1988, Analytical chemistry.

[39]  M Rosenberg,et al.  Halitosis measurement by an industrial sulphide monitor. , 1991, Journal of periodontology.