Minimum-MU and sparse-energy-layer (MMSEL) constrained inverse optimization method for efficiently deliverable PBS plans

The deliverability of proton pencil beam scanning (PBS) plans is subject to the minimum monitor-unit (MU) constraint, while the delivery efficiency depends on the number of proton energy layers. This work develops an inverse optimization method for generating efficiently deliverable PBS plans. The proposed minimum-MU and sparse-energy-layer (MMSEL) constrained inverse optimization method utilizes iterative convex relaxations to handle the nonconvexity from minimum-MU constraint and dose-volume constraints, and regularizes group sparsity of proton spots to minimize the number of energy layers. The tradeoff between plan quality and delivery efficiency (in terms of the number of used energy layers) is controlled by the objective weighting of group sparsity regularization. MMSEL consists of two steps: first minimize for appropriate energy layers, and then with selected energy layers solve for the deliverable PBS plan. The solution algorithm for MMSEL is developed using alternating direction method of multipliers. Range and setup uncertainties are modelled by robust optimization. MMSEL was validated using representative prostate, lung, and head-and-neck (HN) cases. The minimum-MU constraint was strictly enforced for all cases, so that all plans were deliverable. The number of energy layers was reduced by MMSEL to 78%, 76%, and 61% for prostate, lung and HN respectively, while the similar plan quality was achieved. The number of energy layers was reduced by MMSEL to 54%, 57%, and 37% for prostate, lung and HN respectively, while the plan quality was comprised and acceptable. MMSEL is proposed to strictly enforce minimum-MU constraint and minimize the number of energy layers during inverse optimization for efficiently deliverable PBS plans. In particular, the preliminary results suggest MMSEL potentially enables 25% to 40% reduction of energy layers while maintaining the similar plan quality.

[1]  Per Rugaard Poulsen,et al.  Efficient Interplay Effect Mitigation for Proton Pencil Beam Scanning by Spot-Adapted Layered Repainting Evenly Spread out Over the Full Breathing Cycle. , 2018, International journal of radiation oncology, biology, physics.

[2]  Benjamin Clasie,et al.  Minimum MU optimization (MMO): an inverse optimization approach for the PBS minimum MU constraint. , 2019, Physics in medicine and biology.

[3]  D Robertson,et al.  Intensity modulated proton therapy treatment planning using single-field optimization: the impact of monitor unit constraints on plan quality. , 2010, Medical physics.

[4]  Harald Paganetti Proton Beam Therapy , 2016 .

[5]  Yuting Lin,et al.  A Greedy reassignment algorithm for the PBS minimum monitor unit constraint , 2016, Physics in medicine and biology.

[6]  Hao Gao Robust fluence map optimization via alternating direction method of multipliers with empirical parameter optimization. , 2016, Physics in medicine and biology.

[7]  R Mohan,et al.  Algorithms and functionality of an intensity modulated radiotherapy optimization system. , 2000, Medical physics.

[8]  Stephen P. Boyd,et al.  Distributed Optimization and Statistical Learning via the Alternating Direction Method of Multipliers , 2011, Found. Trends Mach. Learn..

[9]  Wei Liu,et al.  Robust optimization in IMPT using quadratic objective functions to account for the minimum MU constraint , 2018, Medical physics.

[10]  Hao Gao,et al.  Hybrid proton-photon inverse optimization with uniformity-regularized proton and photon target dose , 2019, Physics in medicine and biology.

[11]  Wenhua Cao,et al.  Incorporating deliverable monitor unit constraints into spot intensity optimization in intensity-modulated proton therapy treatment planning , 2013, Physics in medicine and biology.

[12]  Tom Goldstein,et al.  The Split Bregman Method for L1-Regularized Problems , 2009, SIAM J. Imaging Sci..

[13]  Katia Parodi,et al.  Development of the open‐source dose calculation and optimization toolkit matRad , 2017, Medical physics.

[14]  Charles S Mayo,et al.  Effects of minimum monitor unit threshold on spot scanning proton plan quality. , 2014, Medical physics.