Frequency of overinstrumentation with an acceptable radiographic working length.

The aim of this in vitro study was to determine how frequent a seemingly accurate working length ending radiographically 0 to 2 mm short of the radiographic apex resulted in an instrumentation beyond the apical foramen. Under simulated clinical conditions working lengths of 169 root canals were radiographically determined in 91 extracted teeth. In all cases the measuring files adjusted to the final working length (Iwork) were located 0 to 2 mm short of the radiographic apex. Iwork was subsequently compared with the actual reference length (Iref) representing the distance between the apical foramen and the coronal reference. Instrumentation beyond the apical foramen (Iwork > ref) occurred in premolars in 51% (95% confidence interval: 36%; 66%) of the cases, in molars in 22% (95% confidence interval: 14%; 30%), and in anterior teeth in no case. These results suggest that in premolars and molars a radiographically working length ending 0 to 2 mm short of the radiographic apex provides, more often than expected, a basis for unintentional overinstrumentation.

[1]  F. Pineda,et al.  Mesiodistal and buccolingual roentgenographic investigation of 7,275 root canals. , 1972, Oral surgery, oral medicine, and oral pathology.

[2]  P M Dummer,et al.  The position and topography of the apical canal constriction and apical foramen. , 1984, International endodontic journal.

[3]  G B Pelleu,et al.  Radiographic interpretation of experimentally produced osseous lesions of the human mandible. , 1977, Journal of endodontics.

[4]  A E Skidmore,et al.  Twenty years of endodontic success and failure. , 1983, Journal of endodontics.

[5]  W. McDavid,et al.  The effect of viewing conditions on the perceptibility of radiographic details. , 1983, Oral surgery, oral medicine, and oral pathology.

[6]  Y. Kuttler,et al.  Microscopic investigation of root apexes. , 1955, Journal of the American Dental Association.

[7]  T. J. Stein,et al.  Radiographic "working length" revisited. , 1992, Oral surgery, oral medicine, and oral pathology.

[8]  R. Weiger,et al.  Prognosis of conventional root canal treatment reconsidered. , 1998, Endodontics & dental traumatology.

[9]  S. Seltzer,et al.  Biologic aspects of endodontics. IV. Periapical tissue reactions to root-filled teeth whose canals had been instrumented short of their apices. , 1969, Oral surgery, oral medicine, and oral pathology.

[10]  D J Setchell,et al.  Factors influencing the success of conventional root canal therapy--a five-year retrospective study. , 1993, International endodontic journal.

[11]  G Sundqvist,et al.  Factors affecting the long-term results of endodontic treatment. , 1990, Journal of endodontics.

[12]  K Langeland,et al.  Apical limit of root canal instrumentation and obturation, part 2. A histological study. , 2002, International endodontic journal.

[13]  A C Goerig,et al.  The ability of the radiograph to determine the location of the apical foramen. , 1991, International endodontic journal.

[14]  S. Friedman,et al.  Evaluation of success and failure after endodontic therapy using a glass ionomer cement sealer. , 1995, Journal of endodontics.

[15]  T R Pitt Ford,et al.  The use of E-speed film for root canal length determination. , 1993, International endodontic journal.

[16]  J H Gutierrez,et al.  Apical foraminal openings in human teeth. Number and location. , 1995, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[17]  R Weiger,et al.  An in vitro comparison of two modern apex locators. , 1999, Journal of endodontics.