Multiparameter Microwave Characterization and Probing of Ultralow Glucose Concentration Using a Microfabricated Biochip

This paper presents a planar biochip consisting of electromagnetically coupled, symmetric, square open loops for the multiparameter microwave characterization of deionized water, a phosphate-buffered saline solution, and a fructose-deionized water solution. The characterization additionally includes the probing of an ultralow glucose concentration in a very small volume of human sera and in solutions of d-glucose powder and deionized water. The interaction between the coupled electromagnetic field and the aqueous solution sample translates into a predictable relationship between the electrical characteristics of the biochip (magnitude and phase of S-parameters, attenuation, phase constant, group delay, characteristic impedance, and effective complex permittivity) and the physical properties of the solution. Owing to the microfabrication technology used for fabricating the proposed microbiochip, it is possible to develop robust, compact square open loops with a microsized coupling gap that characterizes a very small volume (1 μL) of the sample. Additionally, the biochip’s impedance peaks at its resonances were modeled using glucose-level-dependent coupling capacitance between folded square open loops and mutual inductance between center-loaded T-shaped stubs. These peaks linearly shifted in frequencies and markedly varied in impedance. Consequently, a physiologically relevant amount of glucose (50–400 mg/dL) with a high sensitivity (up to 2.036 Ω/(mg·dL−1)) and an ultralow detection limit (up to 4.8 nmol/L) was linearly detected.

[1]  C. Cook,et al.  The promise of electrochemical impedance spectroscopy as novel technology for the management of patients with diabetes mellitus. , 2012, The Analyst.

[2]  K. Won,et al.  Measurement of Diffusion Coefficients of Fluorescence Beads and Quantum Dots Using Fluorescence Correlation Spectroscopy , 2011 .

[3]  Omar M. Ramahi,et al.  Material Characterization Using Complementary Split-Ring Resonators , 2012, IEEE Transactions on Instrumentation and Measurement.

[4]  Kishor Kumar Adhikari,et al.  Ultrahigh-Sensitivity Mediator-Free Biosensor Based on a Microfabricated Microwave Resonator for the Detection of Micromolar Glucose Concentrations , 2016, IEEE Transactions on Microwave Theory and Techniques.

[5]  Pierre Blondy,et al.  Discrimination of colorectal cancer cell lines using microwave biosensors , 2014 .

[6]  A. Salimi,et al.  Non-enzymatic glucose detection free of ascorbic acid interference using nickel powder and nafion sol–gel dispersed renewable carbon ceramic electrode , 2005 .

[7]  Eun-Soo Kim,et al.  Rapid, Sensitive, and Reusable Detection of Glucose by a Robust Radiofrequency Integrated Passive Device Biosensor Chip , 2015, Scientific Reports.

[8]  D. Dubuc,et al.  A Microwave and Microfluidic Planar Resonator for Efficient and Accurate Complex Permittivity Characterization of Aqueous Solutions , 2013, IEEE Transactions on Microwave Theory and Techniques.

[9]  W. Lorenz,et al.  Zur anwendung der transformations—impedanzspektrometrie , 1975 .

[10]  Thomas Y. Hsiang,et al.  Extraction of Subterahertz Transmission-line Parameters of Coplanar Waveguides , 2007 .

[11]  Jong-Gwan Yook,et al.  DNA sensing using split-ring resonator alone at microwave regime , 2010 .

[12]  Nam-Young Kim,et al.  A high performance compact Wilkinson power divider using GaAs-based optimized integrated passive device fabrication process for LTE application , 2015 .

[13]  Kiejin Lee,et al.  Microwave dielectric resonator biosensor for aqueous glucose solution. , 2008, The Review of scientific instruments.

[14]  D. Smith,et al.  Determination of effective permittivity and permeability of metamaterials from reflection and transmission coefficients , 2001, physics/0111203.

[15]  Jie Chen,et al.  A High Performance Enzyme-Free Glucose Sensor Based on the Graphene-CuO Nanocomposites , 2013, International Journal of Electrochemical Science.

[16]  Simge Çınar,et al.  Elucidation of Viscosity Reduction Mechanism of Nano Alumina Suspensions with Fructose Addition by DSC , 2013 .

[17]  Claire F. Gmachl,et al.  In vitro measurements of physiological glucose concentrations in biological fluids using mid-infrared light , 2013, Biomedical optics express.

[18]  Christopher M.A. Brett,et al.  A glucose biosensor using methyl viologen redox mediator on carbon film electrodes , 2005 .

[19]  Bruce D. Hammock,et al.  Impedance Biosensors: Applications to Sustainability and Remaining Technical Challenges , 2014, ACS sustainable chemistry & engineering.

[20]  Mamas I. Prodromidis,et al.  Impedimetric Biosensors and Immunosensors , 2007 .

[21]  Allen J. Bard,et al.  Electroanalytical Chemistry: A Series of Advances , 1974 .

[22]  R. K. Shervedani,et al.  A novel method for glucose determination based on electrochemical impedance spectroscopy using glucose oxidase self-assembled biosensor. , 2006, Bioelectrochemistry.

[23]  Song Zhang,et al.  A novel nonenzymatic sensor based on CuO nanoneedle/graphene/carbon nanofiber modified electrode for probing glucose in saliva. , 2013, Talanta.

[24]  Wenwei Tang,et al.  Glucose Biosensor Based on a Glassy Carbon Electrode Modified with Polythionine and Multiwalled Carbon Nanotubes , 2014, PloS one.

[25]  M. Waqas,et al.  Double Negative Metamaterial of Copper Split Ring and Graphite Materials , 2014 .

[26]  S. Yao,et al.  One‐Pot Preparation of Polymer–Enzyme–Metallic Nanoparticle Composite Films for High‐Performance Biosensing of Glucose and Galactose , 2009 .

[27]  A. Pothier,et al.  Label-free RF biosensors for human cell dielectric spectroscopy , 2009, International Journal of Microwave and Wireless Technologies.

[28]  Nam-Young Kim,et al.  High‐performance integrated passive technology by advanced SI‐GaAs‐based fabrication for RF and microwave applications , 2010 .

[29]  Udo Kaatze,et al.  Molecular Dynamics of Carbohydrate Aqueous Solutions. Dielectric Relaxation as a Function of Glucose and Fructose Concentration , 2001 .