Model predicting discomfort glare caused by LED road lights.

To model discomfort glare from LED road lighting, the effect of four key variables on perceived glare was explored. These variables were: the average glare source luminance (Lg), the background luminance (Lb), the solid angle of the glare source from the perspective of the viewer (ω) and the angle between the glare source and the line of sight (θ). Based on these four variables 72 different light conditions were simulated in a scaled experimental set-up. Participants were requested to judge the perceived discomfort glare of these light conditions using the deBoer rating scale. All four variables and some of their interactions had indeed a significant effect on the deBoer rating. Based on these findings, we developed a model, and tested its general applicability in various verification experiments, including laboratory conditions as well as real road conditions. This verification proved the validity of the model with a correlation between measured and predicted values as high as 0.87 and a residual deviation of about 1 unit on the deBoer rating scale. These results filled the gap in estimating discomfort glare of LED road lighting and clarified similarities of and differences in discomfort glare between LED and traditional light sources.

[1]  H.-J. Schmidt-Clausen,et al.  Assessment of discomfort glare in motor vehicle lighting , 1974 .

[3]  Wendy M. Collins The Determination of the Minimum Identifiable Glare Sensation Interval Using a Pair-Comparison Method , 1962 .

[4]  JD Bullough,et al.  Effect of different coloured luminous surrounds on LED discomfort glare perception , 2013 .

[5]  Michael Sivak,et al.  CONTEXT EFFECTS ON DISCOMFORT GLARE: TASK AND STIMULUS FACTORS , 1990 .

[6]  R. G. Hopkinson,et al.  Discomfort Glare and the Lighting of Buildings , 1950 .

[7]  MS Rea,et al.  Predicting discomfort glare from outdoor lighting installations , 2008 .

[8]  R. G. Mistrick,et al.  Discomfort Glare from Sources of Nonuniform Luminance , 1995 .

[9]  M Rubiño,et al.  Discomfort glare indices: a comparative study. , 1994, Applied optics.

[10]  Steve Fotios,et al.  Lighting for subsidiary streets: investigation of lamps of different SPD. Part 2—Brightness , 2007 .

[11]  Wonwoo Kim,et al.  Effect of Background Luminance on Discomfort Glare in Relation to the Glare Source Size , 2010 .

[12]  M. Sivak,et al.  BLUE CONTENT OF LED HEADLAMPS AND DISCOMFORT GLARE , 2005 .

[13]  Ian J. Murray,et al.  The ocular stress monitor: a new device for measuring discomfort glare , 2002 .

[14]  Masahiro Toda,et al.  Discomfort Glare Caused by White LED Light Sources , 2006 .

[15]  J. Barraza,et al.  Transient glare: its effect on the lower threshold of motion. , 2000, Optics express.

[16]  R. Michael Rubison,et al.  Discomfort Glare: Luminance Range-Limited Replication Study of Angularly Small Sources , 1984 .

[17]  Steve Fotios,et al.  Predicting lamp spectrum effects at mesopic levels. Part 1: Spatial brightness , 2011 .

[18]  Clarence E. Waters,et al.  Subjective Impression of Discomfort Glare from Sources of Non-Uniform Luminance , 2009 .

[19]  Christopher Edwards,et al.  A Review of Disability and Discomfort Glare Research and Future Direction , 2007 .

[20]  John D. Bullough,et al.  Interactions among light source luminance, illuminance and size on discomfort glare , 2012 .

[21]  M. Sliwinski,et al.  Field study of office worker responses to fluorescent lighting of different CCT and lumen output , 2014 .

[22]  Miyoshi Ayama,et al.  Evaluation of discomfort glare from color leds and its correlation with individual variations in brightness sensitivity , 2011 .

[23]  D. Weintraub,et al.  USER RECONFIGURATIONS OF THE DE BOER RATING SCALE FOR DISCOMFORT GLARE , 1990 .

[24]  D. A. Schreuder,et al.  Glare as a Criterion for Quality in Street Lighting , 1967 .

[25]  J. J. Vos On the cause of disability glare and its dependence on glare angle, age and ocular pigmentation , 2003, Clinical & experimental optometry.