Effect of classroom air quality on students' concentration: results of a cluster-randomized cross-over experimental study.

UNLABELLED To assess the effect of indoor air quality as indicated by the median carbon dioxide (CO₂) level in the classroom on the concentration performance (CP) of students, a cross-over cluster-randomized experimental study was conducted in 20 classrooms with mechanical ventilation systems. Test conditions 'worse' (median CO₂ level on average 2115 ppm) and 'better' (median CO₂ level on average 1045 ppm) were established by the regulation of the mechanical ventilation system on two days in one week each in every classroom. Concentration performance was quantified in students of grade three and four by the use of the d2-test and its primary parameter 'CP' and secondary parameters 'total number of characters processed' (TN) and 'total number of errors' (TE). 2366 d2-tests from 417 students could be used in analysis. In hierarchical linear regression accounting for repeated measurements, no significant effect of the experimental condition on CP or TN could be observed. However, TE was increased significantly by 1.65 (95% confidence interval 0.42-2.87) in 'worse' compared to 'better' condition. Thus, low air quality in classrooms as indicated by increased CO₂ levels does not reduce overall short-term CP in students, but appears to increase the error rate. PRACTICAL IMPLICATIONS This study could not confirm that low air quality in classrooms as indicated by increased CO₂ levels reduces short-term concentration performance (CP) in students; however, it appears to affect processing accuracy negatively. To ensure a high level of accuracy, good air quality characterized, for example, by low CO₂ concentration should be maintained in classrooms.

[1]  N. Kochhar,et al.  Ventilation Rates in Schools and Learning Performance , 2007 .

[2]  Pawel Wargocki,et al.  The Effects of Outdoor Air Supply Rate and Supply Air Filter Condition in Classrooms on the Performance of Schoolwork by Children (RP-1257) , 2007 .

[3]  P. Wargocki,et al.  The Effects of Moderately Raised Classroom Temperatures and Classroom Ventilation Rate on the Performance of Schoolwork by Children (RP-1257) , 2007 .

[4]  Allan Donner,et al.  Design and Analysis of Cluster Randomization Trials in Health Research , 2001 .

[5]  Anthony S. Bryk,et al.  Hierarchical Linear Models: Applications and Data Analysis Methods , 1992 .

[6]  Sander Greenland,et al.  Modern Epidemiology 3rd edition , 1986 .

[7]  G. Heath,et al.  Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature. , 2005, Indoor air.

[8]  M G Apte,et al.  Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information. , 2003, Indoor air.

[9]  Gesundheitliche Bewertung von Kohlendioxid in der Innenraumluft , 2008, Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz.

[10]  D Faulkner,et al.  Associations between classroom CO2 concentrations and student attendance in Washington and Idaho. , 2004, Indoor air.

[11]  U Haverinen-Shaughnessy,et al.  A preliminary study on the association between ventilation rates in classrooms and student performance. , 2006, Indoor air.

[12]  U. Haverinen-Shaughnessy,et al.  Association between substandard classroom ventilation rates and students' academic achievement. , 2011, Indoor air.

[13]  M. Bates,et al.  The d2 Test of Attention: Construct validity and extensions in scoring techniques , 2004, Journal of the International Neuropsychological Society.

[14]  Dieter Heitmann,et al.  Raumluftqualität in Schulen - Belastung von Klassenräumen mit Kohlendioxid (CO2), flüchtigen organischen Verbindungen (VOC), Aldehyden, Endotoxinen und Katzenallergenen , 2008 .

[15]  David A. Coley,et al.  The Effect of Low Ventilation Rates on the Cognitive Function of a Primary School Class , 2007 .

[16]  William J. Fisk,et al.  Association of ventilation with health and other responses in commercial and institutional buildings , 2000 .