Adaptive frequency tracking for robust heart rate estimation using wrist-type photoplethysmographic signals during physical exercise

In recent years, wearable photoplethysmographic (PPG) biosensors have emerged as promising tools to monitor heart rate (HR) during physical exercise. However, PPG waveforms are easily corrupted by motion artifacts, rendering HR estimation difficult. In this study, HR was estimated using wrist-type PPG signals. A normalized least-mean-squares (NLMS) algorithm was first used to attenuate motion artifacts and reconstruct multiple PPG waveforms from different combinations of corrupted PPG waveforms and accelerometer (ACC) data. An adaptive band-pass filter was then used to track the common instantaneous frequency component (i.e. HR) of the reconstructed PPG waveforms. Our proposed HR estimation method, which is almost real time, resulted in an average absolute error of 1.71 ± 0.49 beats-per-minute and a Pearson correlation coefficient of 0.994 between the true and the estimated HR values. Importantly, as all ACC-PPG combinations were used for motion artifacts cancellation, no assumption about individual ACC axis contribution was required.

[1]  Haruki Kawanaka,et al.  Estimating heart rate using wrist-type Photoplethysmography and acceleration sensor while running , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[2]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[3]  Jean-Marc Vesin,et al.  Adaptive Tracking of EEG Frequency Components , 2009 .

[4]  Jean-Marc Vesin,et al.  Multi-signal extension of adaptive frequency tracking algorithms , 2009, Signal Process..

[5]  Andrew H. Jazwinski,et al.  Adaptive filtering , 1969, Autom..

[6]  Y. Mendelson,et al.  A noise reference input to an adaptive filter algorithm for signal processing in a wearable pulse oximeter , 2007, 2007 IEEE 33rd Annual Northeast Bioengineering Conference.

[7]  E. Hari Krishna,et al.  A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter , 2012, IEEE Transactions on Instrumentation and Measurement.

[8]  Steve Warren,et al.  Two-Stage Approach for Detection and Reduction of Motion Artifacts in Photoplethysmographic Data , 2010, IEEE Transactions on Biomedical Engineering.

[9]  K. Ashoka Reddy,et al.  Use of Fourier Series Analysis for Motion Artifact Reduction and Data Compression of Photoplethysmographic Signals , 2009, IEEE Transactions on Instrumentation and Measurement.

[10]  Yuan-ting Zhang,et al.  Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution , 2005, Journal of NeuroEngineering and Rehabilitation.

[11]  Zhilin Zhang,et al.  TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise , 2014, IEEE Transactions on Biomedical Engineering.

[12]  Ho-En Liao,et al.  Two discrete oscillator based adaptive notch filters (OSC ANFs) for noisy sinusoids , 2005, IEEE Transactions on Signal Processing.

[13]  Micah M. Murray,et al.  Adaptive tracking of EEG oscillations , 2010, Journal of Neuroscience Methods.