Low-Intensity Ultrasound Stimulation in Distraction Osteogenesis in Rabbits

Low-intensity pulsed ultrasound has been shown to accelerate fracture healing. This experiment investigated its possible role in distraction. Thirty-four New Zealand White rabbits had distraction osteogenesis, followed by low-intensity pulsed ultrasound therapy. Seventeen animals had the ultrasound transducer switched off (controls). Four and 6 weeks postoperatively, tibiae were analyzed using quantitative computed tomography and four-point mechanical testing. Two tibiae from each group had histologic analysis at 4 weeks. No significant differences were identified between regenerates of ultrasound-treated and control groups with respect to bone mineral content, cross-sectional area, and strength. No significant reductions in osteopenia proximal and distal to the regenerate were observed. Histologic observation showed no differences in bone volume fraction, but ultrasound-treated regenerates appeared to have fewer trabeculae of increased thickness, and fewer osteoclasts. The modulation by ultrasound may occur by accelerating endochondral ossification through action on chondrocytes, yet distraction osteogenesis is largely intramembranous. Although ultrasound is proven to be effective in unconstrained systems such as plaster, the current study does not support the role of low-intensity pulsed ultrasound as an adjunct for patients having distraction osteogenesis in a rigid fixator. Additional research is needed to definitively support the use of low-intensity pulsed ultrasound in such situations.

[1]  S A Goldstein,et al.  Temporal and Spatial Characterization of Regenerate Bone in the Lengthened Rabbit Tibia , 1999, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[2]  R F Kilcoyne,et al.  Acceleration of tibial fracture-healing by non-invasive, low-intensity pulsed ultrasound. , 1994, The Journal of bone and joint surgery. American volume.

[3]  C. Cowell,et al.  Effect of pamidronate on distraction osteogenesis and fixator-related osteoporosis. , 2001, Injury.

[4]  J Aronson,et al.  Noninvasive determination of bone stiffness for distraction osteogenesis by quantitative computed tomography scans. , 1994, Clinical orthopaedics and related research.

[5]  J. Ryaby,et al.  Accelerated Healing of Distal Radial Fractures with the Use of Specific, Low-Intensity Ultrasound. A Multicenter, Prospective, Randomized, Double-Blind, Placebo-Controlled Study* , 1997, The Journal of bone and joint surgery. American volume.

[6]  L. R. Duarte The stimulation of bone growth by ultrasound , 2004, Archives of orthopaedic and traumatic surgery.

[7]  J Kenwright,et al.  The role of fixator frame stiffness in the control of fracture healing. An experimental study. , 1993, Journal of biomechanics.

[8]  L Claes,et al.  Radiographic Results of Callus Distraction Aided by Pulsed Low-intensity Ultrasound , 2001, Journal of orthopaedic trauma.

[9]  C. Rubin,et al.  The use of low-intensity ultrasound to accelerate the healing of fractures. , 2001, The Journal of bone and joint surgery. American volume.

[10]  C. Cowell,et al.  Intravenous pamidronate reduces osteoporosis and improves formation of the regenerate during distraction osteogenesis. A study in immature rabbits. , 2001, The Journal of bone and joint surgery. British volume.

[11]  E. Mayr,et al.  [Does low intensity, pulsed ultrasound speed healing of scaphoid fractures?]. , 2000, Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V....

[12]  M. Drezner,et al.  Bone histomorphometry: Standardization of nomenclature, symbols, and units: Report of the asbmr histomorphometry nomenclature committee , 1987, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[13]  Javad Parvizi,et al.  Exposure to low‐intensity ultrasound increases aggrecan gene expression in a rat femur fracture model , 1996, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[14]  Y Yamano,et al.  Low-intensity pulsed ultrasound accelerates bone maturation in distraction osteogenesis in rabbits. , 2000, The Journal of bone and joint surgery. British volume.

[15]  J L Cunningham,et al.  Strain Rate and Timing of Stimulation in Mechanical Modulation of Fracture Healing , 1998, Clinical orthopaedics and related research.

[16]  Javad Parvizi,et al.  Calcium signaling is required for ultrasound‐stimulated aggrecan synthesis by rat chondrocytes , 2002, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[17]  A. Pilla,et al.  Non-invasive low-intensity pulsed ultrasound accelerates bone healing in the rabbit. , 1990, Journal of orthopaedic trauma.

[18]  E. Chao,et al.  Low intensity ultrasound treatment increases strength in a rat femoral fracture model , 1994, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[19]  A. Emami,et al.  No effect of low-intensity ultrasound on healing time of intramedullary fixed tibial fractures. , 1999, Journal of orthopaedic trauma.

[20]  R. G. Johnson,et al.  The restraint of rabbits in a special sling. , 1979, Laboratory animal science.

[21]  Michael Tanzer,et al.  Effect of noninvasive low intensity ultrasound on bone growth into porous‐coated implants , 1996, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[22]  J F Greenleaf,et al.  Low‐intensity ultrasound stimulates proteoglycan synthesis in rat chondrocytes by increasing aggrecan gene expression , 1999, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[23]  J. Kanis,et al.  New bone formation during leg lengthening. Evaluated by dual energy X-ray absorptiometry. , 1993, The Journal of bone and joint surgery. British volume.