Nonrigid registration using a rigidity constraint

Nonrigid registration is a technique commonly used in the field of medical imaging. A drawback of most current nonrigid registration algorithms is that they model all tissue as being nonrigid. When a nonrigid registration is performed, the rigid objects in the image, such as bony structures or surgical instruments, may also transform nonrigidly. Other consequences are that tumour growth between follow-up images may be concealed, or that structures containing contrast material in one image and not in the other may be compressed by the registration algorithm. In this paper we propose a novel regularisation term, which is added to the cost function in order to penalise nonrigid deformations of rigid objects. This regularisation term can be used for any representation of the deformation field capable of modelling locally rigid deformations. By using a B-spline representation of the deformation field, a fast algorithm can be devised. We show on 2D synthetic data, on clinical CT slices, and on clinical DSA images, that the proposed rigidity constraint is successful, thus improving registration results.

[1]  Daniel Rueckert,et al.  Volume and Shape Preservation of Enhancing Lesions when Applying Non-rigid Registration to a Time Series of Contrast Enhancing MR Breast Images , 2000, MICCAI.

[2]  David R. Haynor,et al.  PET-CT image registration in the chest using free-form deformations , 2003, IEEE Transactions on Medical Imaging.

[3]  D. Hill,et al.  Deformations incorporating rigid structures [medical imaging] , 1996, Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis.

[4]  Michael Unser,et al.  Optimization of mutual information for multiresolution image registration , 2000, IEEE Trans. Image Process..

[5]  J. Modersitzki,et al.  A unified approach to fast image registration and a new curvature based registration technique , 2004 .

[6]  Josien P. W. Pluim,et al.  Comparison of gradient approximation techniques for optimisation of mutual information in nonrigid registration , 2005, SPIE Medical Imaging.

[7]  Michael Unser,et al.  Splines: a perfect fit for signal and image processing , 1999, IEEE Signal Process. Mag..

[8]  Torsten Rohlfing,et al.  Volume-preserving nonrigid registration of MR breast images using free-form deformation with an incompressibility constraint , 2003, IEEE Transactions on Medical Imaging.

[9]  Daniel Rueckert,et al.  Nonrigid registration using free-form deformations: application to breast MR images , 1999, IEEE Transactions on Medical Imaging.

[10]  Torsten Rohlfing,et al.  Intensity-Based Non-rigid Registration Using Adaptive Multilevel Free-Form Deformation with an Incompressibility Constraint , 2001, MICCAI.

[11]  Gary E. Christensen,et al.  Consistent image registration , 2001, IEEE Transactions on Medical Imaging.