Data acquisition electronics for gamma ray emission tomography using width-modulated leading-edge discriminators

We present a new high-performance and low-cost approach for implementing radiation detection acquisition systems. The basic elements used are charge-integrating ADCs and a set of components encapsulated in an HDL (hardware definition language) library which makes it possible to implement several acquisition tasks such as time pickoff and coincidence detection using a new and simple trigger technique that we name WMLET (width-modulated leading-edge timing). As proof of concept, a 32-channel hybrid PET/SPECT acquisition system based on these elements was developed and tested. This demonstrator consists of a master module responsible for the generation and distribution of trigger signals, 2 x 16-channel ADC cards (12-bit resolution) for data digitization and a 32-bit digital I/O PCI card for handling data transmission to a personal computer. System characteristics such as linearity, maximum transmission rates or timing resolution in coincidence mode were evaluated with test and real detector signals. Imaging capabilities of the prototype were also evaluated using different detector configurations. The performance tests showed that this implementation is able to handle data rates in excess of 600k events s(-1) when acquiring simultaneously 32 channels (96-byte events). ADC channel linearity is >98.5% in energy quantification. Time resolution in PET mode for the tested configurations ranges from 3.64 ns FWHM to 7.88 ns FWHM when signals from LYSO-based detectors are used. The measured energy resolution matched the expected values for the detectors evaluated and single elements of crystal matrices can be neatly separated in the acquired flood histograms.

[1]  D P McElroy,et al.  A true singles list-mode data acquisition system for a small animal PET scanner with independent crystal readout , 2005, Physics in medicine and biology.

[2]  Bernd J Pichler,et al.  Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors , 2005, Physics in medicine and biology.

[3]  M. Desco,et al.  Real-Time Digital Timing in Positron Emission Tomography , 2008, IEEE Transactions on Nuclear Science.

[4]  S. Majewski,et al.  A flexible high-rate USB2 data acquisition system for PET and SPECT imaging , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[5]  C. Laymon,et al.  Simplified FPGA-based data acquisition system for PET , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[6]  W W Moses,et al.  OpenPET: A Flexible Electronics System for Radiotracer Imaging , 2009, IEEE Transactions on Nuclear Science.

[7]  J. W. Young,et al.  FPGA based front-end electronics for a high resolution PET scanner , 1999 .

[8]  Spencer L Bowen,et al.  PET characteristics of a dedicated breast PET/CT scanner prototype , 2009, Physics in medicine and biology.

[9]  R. Fontaine,et al.  Crystal Identification Based on Recursive-Least-Squares and Least-Mean-Squares Auto-Regressive Models for Small Animal Pet , 2008, IEEE Transactions on Nuclear Science.

[10]  M. Desco,et al.  New embedded digital front-end for high resolution PET scanner , 2006, IEEE Transactions on Nuclear Science.

[11]  Craig S. Levin,et al.  Compact readout electronics for position sensitive photomultiplier tubes , 2003 .

[12]  A Rodríguez-Ruano,et al.  Design and performance evaluation of a coplanar multimodality scanner for rodent imaging. , 2009, Physics in medicine and biology.

[13]  J. Benlloch,et al.  Analysis of time resolution in a dual head LSO+PSPMT PET system using low pass filter interpolation and digital constant fraction discriminator techniques , 2009 .

[14]  M. Desco,et al.  rSPECT: A compact gamma camera based SPECT system for small-animal imaging , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[15]  M. Moszynski,et al.  New Prospects for Time-of-Flight PET With LSO Scintillators , 2006, IEEE Transactions on Nuclear Science.

[16]  Sibylle Ziegler,et al.  An analog signal processing ASIC for a small animal LSO–APD PET tomograph , 2006 .

[17]  R. Fontaine,et al.  Crystal identification based on recursive-least-squares and least-mean-squares autoregressive models for small animal PET , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[18]  M. Desco,et al.  Performance evaluation of a new gamma imager for small animal SPECT applications , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[19]  P. O'Connor,et al.  Front-end electronics for the RatCAP mobile animal PET scanner , 2004, IEEE Transactions on Nuclear Science.

[20]  M. Desco,et al.  rPET detectors design and data processing , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[21]  M. Desco,et al.  Assessment of a New High-Performance Small-Animal X-Ray Tomograph , 2008, IEEE Transactions on Nuclear Science.

[22]  G. Brandenburg,et al.  The data acquisition system of ClearPET neuro - a small animal PET scanner , 2006, IEEE Transactions on Nuclear Science.

[23]  R. Fontaine,et al.  The Hardware and Signal Processing Architecture of LabPET™, a Small Animal APD-Based Digital PET Scanner , 2009, IEEE Transactions on Nuclear Science.

[24]  Yuxuan Zhang,et al.  A New Statistics-Based Online Baseline Restorer for a High Count-Rate Fully Digital System , 2009, IEEE Transactions on Nuclear Science.

[25]  A. Del Guerra,et al.  Preliminary test results on the new electronic readout of the YAP(S)PET small animal scanner , 2001, IEEE Nuclear Science Symposium Conference Record.

[26]  A.G. Weisenberger,et al.  Implementation of a High-Rate USB Data Acquisition System for PET and SPECT Imaging , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[28]  Manuel Desco,et al.  Performance evaluation of SiPM detectors for PET imaging in the presence of magnetic fields , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.