Evaluation of micromilled metal mold masters for the replication of microchip electrophoresis devices

High-precision micromilling was assessed as a tool for the rapid fabrication of mold masters for replicating microchip devices in thermoplastics. As an example, microchip electrophoresis devices were hot embossed in poly(methylmethacrylate) (PMMA) from brass masters fabricated via micromilling. Specifically, sidewall roughness and milling topology limitations were investigated. Numerical simulations were performed to determine the effects of additional volumes present on injection plugs (i.e., shape, size, concentration profiles) due to curvature of the corners produced by micromilling. Elongation of the plug was not dramatic (< 20%) for injection crosses with radii of curvatures to channel width ratios less than 0.5. Use of stronger pinching potentials, as compared to sharp-corner injectors, were necessary in order to obtain short sample plugs. The sidewalls of the polymer microstructures were characterized by a maximum average roughness of 115 nm and mean peak height of 290 nm. Sidewall roughness had insignificant effects on the bulk EOF as it was statistically the same for PMMA microchannels with different aspect ratios compared to LiGA-prepared devices with a value of ca. 3.7 × 10−4 cm2/(V s). PMMA microchip electrophoresis devices were used for the separation of pUC19 Sau3AI double-stranded DNA. The plate numbers achieved in the micromilled-based chips exceeded 1 million/m and were comparable to the plate numbers obtained for the LiGA-prepared devices of similar geometry.

[1]  Axel Bertholds,et al.  Microelectro discharge machining as a technology in micromachining , 1996, Photonics West - Micro and Nano Fabricated Electromechanical and Optical Components.

[2]  Mandy B Esch,et al.  Influence of master fabrication techniques on the characteristics of embossed microfluidic channels. , 2003, Lab on a chip.

[3]  Yu-jiang Xie,et al.  Vacuum-assisted thermal bonding of plastic capillary electrophoresis microchip imprinted with stainless steel template. , 2004, Journal of chromatography. A.

[4]  R. Zare,et al.  Current-monitoring method for measuring the electroosmotic flow rate in capillary zone electrophoresis , 1988 .

[5]  Justin S. Mecomber,et al.  Analytical performance of polymer-based microfluidic devices fabricated by computer numerical controlled machining. , 2006, Analytical chemistry.

[6]  G. Slater,et al.  Electrophoretic resolution versus fluctuations of the lateral dimensions of a capillary , 1995, Electrophoresis.

[7]  Francis Barany,et al.  Capillary and microelectrophoretic separations of ligase detection reaction products produced from low‐abundant point mutations in genomic DNA , 2004, Electrophoresis.

[8]  Xu,et al.  Room-temperature imprinting method for plastic microchannel fabrication , 2000, Analytical chemistry.

[9]  H. Girault,et al.  Photomodification of polymer microchannels induced by static and dynamic excimer ablation: effect on the electroosmotic flow. , 2001, Analytical chemistry.

[10]  Binayak Roy,et al.  Rapid fabrication of a poly(dimethylsiloxane) microfluidic capillary gel electrophoresis system utilizing high precision machining. , 2003, Lab on a chip.

[11]  A. Guber,et al.  Microfluidic lab-on-a-chip systems based on polymers - fabrication and application , 2004 .

[12]  Jeffery H. Fenton,et al.  A miniature integrated device for automated multistep genetic assays. , 2000, Nucleic acids research.

[13]  Regina Luttge,et al.  Comparison of capillary zone electrophoresis performance of powder‐blasted and hydrogen fluoride‐etched microchannels in glass , 2003, Electrophoresis.

[14]  C. Culbertson,et al.  Microchip Structures for Submillisecond Electrophoresis , 1998 .

[15]  Kun Lian,et al.  Microfluidic devices fabricated in poly(methyl methacrylate) using hot-embossing with integrated sampling capillary and fiber optics for fluorescence detection. , 2002, Lab on a chip.

[16]  Robin H. Liu,et al.  Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection. , 2004, Analytical chemistry.

[17]  Solute Dispersion by Electroosmotic flow in Nonuniform Microfluidic Channels , 2001 .

[18]  Ford,et al.  Polymeric microelectromechanical systems , 2000, Analytical chemistry.

[19]  Ralf Lenigk,et al.  DNA amplification and hybridization assays in integrated plastic monolithic devices. , 2002, Analytical chemistry.

[20]  Jost Goettert,et al.  Direct fabrication of deep x-ray lithography masks by micromechanical milling , 1998 .

[21]  H. Becker,et al.  Polymer microfluidic devices. , 2002, Talanta.

[22]  Gwo-Bin Lee,et al.  Microfabricated plastic chips by hot embossing methods and their applications for DNA separation and detection , 2000, SPIE MOEMS-MEMS.

[23]  Bailey,et al.  Separation and detection of explosives on a microchip using micellar electrokinetic chromatography and indirect laser-induced fluorescence , 2000, Analytical chemistry.

[24]  Steven A Soper,et al.  Electrokinetically synchronized polymerase chain reaction microchip fabricated in polycarbonate. , 2005, Analytical chemistry.

[25]  C Gärtner,et al.  Polymer microfabrication methods for microfluidic analytical applications , 2000, Electrophoresis.

[26]  A Manz,et al.  Narrow sample channel injectors for capillary electrophoresis on microchips. , 2001, Analytical chemistry.

[27]  R. G. Christensen,et al.  Fabrication of plastic microfluid channels by imprinting methods. , 1997, Analytical chemistry.

[28]  J Michael Ramsey,et al.  Strategy for repetitive pinched injections on a microfluidic device. , 2004, Analytical chemistry.

[29]  John G. Dorsey,et al.  Equations for calculation of chromatographic figures of merit for ideal and skewed peaks , 1983 .

[30]  S. Jacobson,et al.  Computer simulations of electrokinetic injection techniques in microfluidic devices , 2000, Analytical chemistry.

[31]  D. J. Harrison,et al.  Electrokinetic control of fluid flow in native poly(dimethylsiloxane) capillary electrophoresis devices , 2000, Electrophoresis.

[32]  Andreas E. Guber,et al.  Microfabrication of single-use plastic microfluidic devices for high-throughput screening and DNA analysis , 2002 .

[33]  D. J. Harrison,et al.  Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip , 1993, Science.

[34]  Andreas Manz,et al.  High-Speed Separation of Antisense Oligonucleotides on a Micromachined Capillary Electrophoresis Device , 1994 .

[35]  Lothar Bohn,et al.  Microstructure grooves with a width of less than 50 μm cut with ground hard metal micro end mills , 1999 .

[36]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[37]  L. Fu,et al.  Electrokinetic injection techniques in microfluidic chips. , 2002, Analytical chemistry.

[38]  A. Manz,et al.  Micro total analysis systems. Recent developments. , 2004, Analytical chemistry.

[39]  R S Foote,et al.  Electrophoretic separation of proteins on a microchip with noncovalent, postcolumn labeling. , 2000, Analytical chemistry.

[40]  István Mészáros,et al.  Micromilling of metallic materials , 2003 .

[41]  Lung-Ming Fu,et al.  Electrokinetic focusing injection methods on microfluidic devices. , 2003, Analytical chemistry.

[42]  A. Manz,et al.  Glass chips for high-speed capillary electrophoresis separations with submicrometer plate heights , 1993 .

[43]  J. Michael Ramsey,et al.  Effects of injection schemes and column geometry on the performance of microchip electrophoresis devices , 1994 .

[44]  Francis Barany,et al.  Fabrication of DNA microarrays onto poly(methyl methacrylate) with ultraviolet patterning and microfluidics for the detection of low-abundant point mutations. , 2005, Analytical biochemistry.

[45]  A. Ricco,et al.  Peer Reviewed: Plastic Advances Microfluidic Devices , 2002 .