Energy saving and indoor thermal comfort evaluation using a novel local exhaust ventilation system for office rooms.

Energy saving, indoor thermal comfort and inhaled air quality in an office are strongly affected by the flow interaction in the micro-environment around the occupants. The local exhaust ventilation system, which aims to control the transmission of contaminant and extract contaminant air locally, is widely used in industrial applications. In this study, the concept of the local exhaust ventilation system is developed for use in office applications. Consequently, a novel local exhaust ventilation system for offices was combined with an office work station in one unit. Energy saving, thermal comfort and inhaled air quality were used to evaluate the performance of the new system. Experimental data from published work are used to validate the computational fluid dynamic model of this study. The performance of the new system for three different amounts of recirculated air (35%, 50%, and 65% of the total mass flow rate) was investigated numerically in an office room with and without using the new system to show its impact on energy saving, thermal comfort and inhaled air quality. The result shows that the new local exhaust ventilation system can reduce the energy consumption by up to 30%, compared with an office not using this system. Furthermore, this system was able to reduce the contaminant concentration in a micro-environment area by up to 61% and improve the human thermal comfort in the occupied zone. It can be concluded that using the local exhaust ventilation concept can make significant improvements to the quality of inhaled air and produce extra energy saving with an acceptable thermal comfort.

[1]  Chao-Hsin Lin,et al.  Advanced turbulence models for predicting particle transport in enclosed environments , 2012 .

[2]  Wei Shen,et al.  A techno-economic comparison of a direct expansion ground-source and a secondary loop ground-coupled heat pump system for cooling in a residential building , 2012 .

[3]  P. O. Fanger,et al.  Thermal comfort: analysis and applications in environmental engineering, , 1972 .

[4]  W. Nazaroff Indoor particle dynamics. , 2004, Indoor air.

[5]  Ryan K. Dygert,et al.  Mitigation of cross-contamination in an aircraft cabin via localized exhaust , 2010 .

[6]  M. L. Laucks,et al.  Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles , 2000 .

[7]  Shafqat Hussain,et al.  Numerical investigations of buoyancy-driven natural ventilation in a simple atrium building and its effect on the thermal comfort conditions , 2012 .

[8]  Tengfei Zhang,et al.  Novel air distribution systems for commercial aircraft cabins , 2007 .

[9]  Peter V. Nielsen,et al.  Risk of cross-infection in a hospital ward with downward ventilation , 2010 .

[10]  W. M. Li,et al.  Risk assessment of exposure to volatile organic compounds in different indoor environments. , 2004, Environmental research.

[11]  Ryan K. Dygert,et al.  Experimental validation of local exhaust strategies for improved IAQ in aircraft cabins , 2012 .

[12]  A. Melikov,et al.  Novel ventilation strategy for reducing the risk of airborne cross infection in hospital rooms , 2011 .

[13]  K. F. Fong,et al.  Effect of neutral temperature on energy saving of centralized air-conditioning systems in subtropical Hong Kong , 2010 .

[14]  Peter V. Nielsen,et al.  Dispersion of exhalation pollutants in a two-bed hospital ward with a downward ventilation system , 2008 .

[15]  Shian Gao,et al.  A numerical study on the effects of exhaust locations on energy consumption and thermal environment in an office room served by displacement ventilation , 2016 .

[16]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[17]  Bin Zhao,et al.  Comparison of indoor aerosol particle concentration and deposition in different ventilated rooms by numerical method , 2004 .

[18]  Jun Yao,et al.  Modelling conjugate flow and heat transfer in a ventilated room for indoor thermal comfort assessment , 2014 .

[19]  W. H. Engelmann,et al.  The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutants , 2001, Journal of Exposure Analysis and Environmental Epidemiology.

[20]  Cesare Maria Joppolo,et al.  Numerical and experimental analysis of airborne particles control in an operating theater , 2015 .

[21]  A. Q. Ahmed,et al.  Thermal Comfort and Energy Saving Evaluation of a Combined System in an Office Room Using Displacement Ventilation , 2015 .

[22]  Chandra Sekhar,et al.  Performance evaluation of an integrated Personalized Ventilation–Personalized Exhaust system in conjunction with two background ventilation systems , 2014 .

[23]  Sture Holmberg,et al.  Effect of a portable ultra-clean exponential airflow unit on the particle distribution in an operating room , 2015 .

[24]  M. Rizk,et al.  The motion of a spherical particle suspended in a turbulent flow near a plane wall , 1985 .

[25]  Qingyan Chen,et al.  Experimental measurements and numerical simulations of particle transport and distribution in ventilated rooms , 2006 .

[26]  William W. Nazaroff,et al.  Mathematical Modeling of Indoor Aerosol Dynamics , 1989 .

[27]  J. I. Rosell,et al.  Building integration of concentrating systems for solar cooling applications , 2013 .

[28]  S. Orszag,et al.  Development of turbulence models for shear flows by a double expansion technique , 1992 .

[29]  Goodarz Ahmadi,et al.  Dispersion and Deposition of Spherical Particles from Point Sources in a Turbulent Channel Flow , 1992 .

[30]  A. Lai,et al.  Modeling particle distribution and deposition in indoor environments with a new drift–flux model , 2006 .

[31]  Jun Yao,et al.  NUMERICAL STUDY OF UNSTEADY AIRFLOW PHENOMENA IN A VENTILATED ROOM , 2012 .

[32]  Pavel Zítek,et al.  Novel personalized and humidified air supply for airliner passengers , 2010 .

[33]  Haiying Wang,et al.  Experimental Study of Factors That Affect Thermal Comfort in an Upward-Displacement Air-Conditioned Room , 2002 .

[34]  I. Annesi-Maesano,et al.  Indoor air pollution and airway disease. , 2004, The International Journal of Tuberculosis and Lung Disease.

[35]  Arsen Krikor Melikov,et al.  Control of the Free Convective Flow around the Human Body for Enhanced Inhaled Air Quality: Application to a Seat-Incorporated Personalized Ventilation Unit , 2010 .

[36]  Qingyan Chen,et al.  Comparison of the Eulerian and Lagrangian methods for predicting particle transport in enclosed spaces , 2007 .

[37]  L. Morawska,et al.  Determination of particle concentration in the breathing zone for four different types of office ventilation systems , 2009 .

[38]  Rajnish K. Calay,et al.  A hybrid energy efficient building ventilation system , 2013 .

[39]  P. Saffman The lift on a small sphere in a slow shear flow , 1965, Journal of Fluid Mechanics.

[40]  Qingyan Chen,et al.  Simplified Numerical Models for Complex Air Supply Diffusers , 2002 .

[41]  Jianlei Niu,et al.  Experimental and numerical investigations on stratified air distribution systems with special configuration: Thermal comfort and energy saving , 2013 .

[42]  Jelena Srebric,et al.  Contaminant dispersion with personal displacement ventilation, Part I: Base case study , 2009 .

[43]  K.W.D. Cheong,et al.  Development of ventilation design strategy for effective removal of pollutant in the isolation room of a hospital , 2006 .

[44]  Qingyan Chen,et al.  Measurements and computations of room airflow with displacement ventilation , 1999 .

[45]  Chandra Sekhar,et al.  Computational fluid dynamics study and evaluation of different personalized exhaust devices , 2013 .

[46]  Yufeng Yao,et al.  Numerical optimisation of thermal comfort improvement for indoor environment with occupants and furniture , 2015 .

[47]  J. McLaughlin Aerosol particle deposition in numerically simulated channel flow , 1989 .

[48]  J. Cuevas,et al.  Radiative Heat Transfer , 2018, ACS Photonics.

[49]  K W Tham,et al.  Human convection flow in spaces with and without ventilation: personal exposure to floor-released particles and cough-released droplets. , 2015, Indoor air.