A time-gated near-infrared spectroscopic imaging device for clinical applications.

A time-resolved, spectroscopic, diffuse optical tomography device was assembled for clinical applications like brain functional imaging. The entire instrument lies in a unique setup that includes a light source, an ultrafast time-gated intensified camera and all the electronic control units. The light source is composed of four near infrared laser diodes driven by a nanosecond electrical pulse generator working in a sequential mode at a repetition rate of 100 MHz. The light pulses are less than 80 ps FWHM. They are injected in a four-furcated optical fiber ended with a frontal light distributor to obtain a uniform illumination spot directed towards the head of the patient. Photons back-scattered by the subject are detected by the intensified CCD camera. There are resolved according to their time of flight inside the head. The photocathode is powered by an ultrafast generator producing 50 V pulses, at 100 MHz and a width corresponding to a 200 ps FWHM gate. The intensifier has been specially designed for this application. The whole instrument is controlled by an FPGA based module. All the acquisition parameters are configurable via software through an USB plug and the image data are transferred to a PC via an Ethernet link. The compactness of the device makes it a perfect device for bedside clinical applications. The instrument will be described and characterized. Preliminary data recorded on test samples will be presented.

[1]  F. Nouizi,et al.  Time-gated near-infrared spectroscopic imaging of brain activation: a simulation proof of concept , 2011, BiOS.

[2]  S R Arridge,et al.  Recent advances in diffuse optical imaging , 2005, Physics in medicine and biology.

[3]  S. Umeyama,et al.  Multidistance probe arrangement to eliminate artifacts in functional near-infrared spectroscopy. , 2009, Journal of biomedical optics.

[4]  Wilfried Uhring,et al.  200 ps FWHM and 100 MHz repetition rate ultrafast gated camera for optical medical functional imaging , 2012, Photonics Europe.

[5]  P. Poulet,et al.  Detection of cortical activation with time-resolved diffuse optical methods. , 2005, Applied optics.

[6]  Piotr Sawosz,et al.  Optical system based on time-gated, intensified charge-coupled device camera for brain imaging studies. , 2010, Journal of biomedical optics.

[7]  Y. Hoshi Functional near-infrared spectroscopy: potential and limitations in neuroimaging studies. , 2005, International review of neurobiology.

[8]  Sung-Ho Han,et al.  In vivo simultaneous monitoring of two fluorophores with lifetime contrast using a full-field time domain system. , 2009, Applied optics.

[9]  Martin Wolf,et al.  Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications. , 2007, Journal of biomedical optics.

[10]  R. Cubeddu,et al.  Functional tomography using a time-gated ICCD camera , 2011, Biomedical optics express.

[11]  A. Sorensen,et al.  Improved sensitivity to cerebral hemodynamics during brain activation with a time-gated optical system: analytical model and experimental validation. , 2005, Journal of biomedical optics.

[12]  Wilfried Uhring,et al.  SPIRIT : un projet de spectroscopie proche infrarouge par imagerie temporelle , 2008 .

[13]  Wilfried Uhring,et al.  A low-cost high-repetition-rate picosecond laser diode pulse generator , 2004, SPIE Photonics Europe.

[14]  F. Jöbsis Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. , 1977, Science.

[15]  A. Maki,et al.  Optical topography: practical problems and new applications. , 2003, Applied optics.