Some Effects of Beam Thickness on Photon Migration in a Turbid Medium

Abstract We analyse the effects of extended rather than point optodes on several properties of photon migration in a turbid medium with internal absorption in a diffusion model suggested by a number of biomedical applications. The parameters considered include the surface flux of photons re-emitted back through the surface as a function of distance from the centre of the injecting optode, the surface intensity profile as a function of time for optodes separated by a fixed distance, and the distribution of the maximum depth reached by a photon, conditional on its being re-emitted through the interface at a variable distance from the injection point. Our major result is that the effects of extended optodes are much more significant when internal absorption is high.

[1]  S Nioka,et al.  Quantitation of time- and frequency-resolved optical spectra for the determination of tissue oxygenation. , 1991, Analytical biochemistry.

[2]  Oberg Pa,et al.  Laser-Doppler flowmetry. , 1990, Critical reviews in biomedical engineering.

[3]  G. Weiss,et al.  Model for photon migration in turbid biological media. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[4]  M. Stern,et al.  In vivo evaluation of microcirculation by coherent light scattering , 1975, Nature.

[5]  S. Jacques,et al.  Light distributions in artery tissue: Monte Carlo simulations for finite‐diameter laser beams , 1989, Lasers in surgery and medicine.

[6]  Akira Ishimaru,et al.  Diffusion of a pulse in densely distributed scatterers , 1978 .

[7]  T. King,et al.  Aspects of laser light scattering from skin tissue with application to laser Doppler blood flow measurement. , 1984, Physics in medicine and biology.

[8]  B. Wilson,et al.  Monte Carlo modeling of light propagation in highly scattering tissues. I. Model predictions and comparison with diffusion theory , 1989, IEEE Transactions on Biomedical Engineering.

[9]  D. Weitz,et al.  Diffusing wave spectroscopy. , 1988, Physical review letters.

[10]  C. C. Johnson Optical diffusion in blood. , 1970, IEEE transactions on bio-medical engineering.

[11]  R. Nossal,et al.  Model for laser Doppler measurements of blood flow in tissue. , 1981, Applied optics.

[12]  D. Weitz,et al.  Diffusing-wave spectroscopy : dynamic light scattering in the multiple scattering limit , 1990 .

[13]  S Nioka,et al.  Comparison of time-resolved and -unresolved measurements of deoxyhemoglobin in brain. , 1988, Proceedings of the National Academy of Sciences of the United States of America.

[14]  G. Weiss,et al.  Solutions of the telegrapher's equation in the presence of traps. , 1992, Physical review. A, Atomic, molecular, and optical physics.

[15]  B. Wilson,et al.  Time resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties. , 1989, Applied optics.

[16]  R Nossal,et al.  Influence of path length on remote optical sensing of properties of biological tissue. , 1989, Applied optics.

[17]  S. Arridge,et al.  Estimation of optical pathlength through tissue from direct time of flight measurement , 1988 .