Current injection for active islanding detection of electronically-interfaced distributed resources

This paper presents an active islanding detection method for electronically-interfaced distributed resource units at the distribution voltage level. The proposed method is based on injecting a disturbance signal into the system through either the direct axis (d-axis) or the quadrature axis (q-axis) current controllers of the interface voltage-sourced converter. Signal injection through the d-axis controller modulates the amplitude of the voltage at the point of common coupling (PCC), whereas signal injection through the q-axis controller causes a frequency deviation at PCC, under islanded conditions. Monitoring strategies to detect islanding are also presented for the proposed injection method. The feasibility of the proposed method is evaluated under the UL1741 anti-islanding test configuration. The studies reported in this paper are based on time-domain simulations in the PSCAD/EMTDC environment. The studies show that the proposed islanding detection method succeeds in detecting the islanding phenomenon as fast as 33.3 ms for the parameter setting of the test system, and always meets the two-second UL detection requirement. The paper also concludes that the proposed method has the salient feature of offering a potential application in a micro-grid scenario, where fast "islanding detection" and not necessarily the "anti-islanding function" is required.

[1]  Shyh-Jier Huang,et al.  A new approach to islanding detection of dispersed generators with self-commutated static power converters , 2000 .

[2]  V. John,et al.  Investigation of anti-islanding protection of power converter based distributed generators using frequency domain analysis , 2004, IEEE Transactions on Power Electronics.

[3]  Ajeet Rohatgi,et al.  Determining the relative effectiveness of islanding detection methods using phase criteria and nondetection zones , 2000 .

[4]  Ajeet Rohatgi,et al.  Analysis and performance assessment of the active frequency drift method of islanding prevention , 1999 .

[5]  Sung-Il Jang,et al.  An islanding detection method for distributed generations using voltage unbalance and total harmonic distortion of current , 2004, IEEE Transactions on Power Delivery.

[6]  W. Bower,et al.  Evaluation of Islanding Detection Methods for Utility-Interactive Inverters in Photovoltaic Systems , 2002 .

[7]  Russell H. Bonn,et al.  Results of Sandia National Laboratories grid-tied inverter testing , 1998 .

[8]  Chern-Lin Chen,et al.  Automatic phase-shift method for islanding detection of grid-connected photovoltaic inverters , 2002 .

[9]  P.W. Lehn,et al.  Micro-grid autonomous operation during and subsequent to islanding process , 2005, IEEE Transactions on Power Delivery.

[10]  M. B. Brennen,et al.  Vector analysis and control of advanced static VAr compensators , 1991 .

[11]  N.W. Miller,et al.  Distributed generation islanding-implications on power system dynamic performance , 2002, IEEE Power Engineering Society Summer Meeting,.

[12]  Kwang-Ho Kim,et al.  Development of a logical rule-based islanding detection method for distributed resources , 2002, 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309).

[13]  Zhihong Ye,et al.  Investigation of antiislanding protection of power converter based distributed generators using frequency domain analysis , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[14]  Se-Kyo Chung,et al.  A phase tracking system for three phase utility interface inverters , 2000 .