Dose reduction in pediatric abdominal CT: use of iterative reconstruction techniques across different CT platforms

Dose reduction in children undergoing CT scanning is an important priority for the radiology community and public at large. Drawbacks of radiation reduction are increased image noise and artifacts, which can affect image interpretation. Iterative reconstruction techniques have been developed to reduce noise and artifacts from reduced-dose CT examinations, although reconstruction algorithm, magnitude of dose reduction and effects on image quality vary. We review the reconstruction principles, radiation dose potential and effects on image quality of several iterative reconstruction techniques commonly used in clinical settings, including 3-D adaptive iterative dose reduction (AIDR-3D), adaptive statistical iterative reconstruction (ASIR), iDose, sinogram-affirmed iterative reconstruction (SAFIRE) and model-based iterative reconstruction (MBIR). We also discuss clinical applications of iterative reconstruction techniques in pediatric abdominal CT.

[1]  The ALARA (as low as reasonably achievable) concept in pediatric CT intelligent dose reduction. Multidisciplinary conference organized by the Society of Pediatric Radiology. August 18-19, 2001. , 2002, Pediatric radiology.

[2]  Ashok Panigrahy,et al.  Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility study , 2011, Pediatric Radiology.

[3]  F. Gudinchet,et al.  Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality – preliminary findings , 2011, Pediatric Radiology.

[4]  L. Tanoue Computed Tomography — An Increasing Source of Radiation Exposure , 2009 .

[5]  M. Callahan,et al.  CT dose reduction in practice , 2011, Pediatric Radiology.

[6]  S. Schindera,et al.  Hybrid iterative reconstruction technique for abdominal CT protocols in obese patients: assessment of image quality, radiation dose, and low-contrast detectability in a phantom. , 2014, AJR. American journal of roentgenology.

[7]  Noise-reducing algorithms do not necessarily provide superior dose optimisation for hepatic lesion detection with multidetector CT. , 2013, The British journal of radiology.

[8]  M. Körner,et al.  Filtered back projection, adaptive statistical iterative reconstruction, and a model-based iterative reconstruction in abdominal CT: an experimental clinical study. , 2013, Radiology.

[9]  M. Maher,et al.  A prospective feasibility study of sub-millisievert abdominopelvic CT using iterative reconstruction in Crohn’s disease , 2013, European Radiology.

[10]  Atul Padole,et al.  Computed Tomography (CT) of the Chest at Less Than 1 mSv: An Ongoing Prospective Clinical Trial of Chest CT at Submillisievert Radiation Doses with Iterative Model Image Reconstruction and iDose4 Technique , 2014, Journal of computer assisted tomography.

[11]  Samuel L Brady,et al.  Pediatric CT: implementation of ASIR for substantial radiation dose reduction while maintaining pre-ASIR image noise. , 2013, Radiology.

[12]  James H Thrall,et al.  Radiation dose reduction with hybrid iterative reconstruction for pediatric CT. , 2012, Radiology.

[13]  Thomas L Toth,et al.  Dose reduction and compliance with pediatric CT protocols adapted to patient size, clinical indication, and number of prior studies. , 2009, Radiology.

[14]  D. Cody,et al.  Techniques and tactics for optimizing CT dose in adults and children: state of the art and future advances. , 2014, Journal of the American College of Radiology : JACR.

[15]  Keith J Strauss,et al.  Image gently: Ten steps you can take to optimize image quality and lower CT dose for pediatric patients. , 2010, AJR. American journal of roentgenology.

[16]  Varut Vardhanabhuti,et al.  Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi , 2013, Insights into Imaging.

[17]  Donald P Frush,et al.  CT with a computer-simulated dose reduction technique for detection of pediatric nephroureterolithiasis: comparison of standard and reduced radiation doses. , 2009, AJR. American journal of roentgenology.

[18]  S. Brady,et al.  Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective. , 2012, Medical physics.

[19]  M. Goodsitt,et al.  Model-based iterative reconstruction: effect on patient radiation dose and image quality in pediatric body CT. , 2013, Radiology.

[20]  D. Volders,et al.  Model-based iterative reconstruction and adaptive statistical iterative reconstruction techniques in abdominal CT: comparison of image quality in the detection of colorectal liver metastases. , 2013, Radiology.

[21]  Yun Liang,et al.  Optimization of hybrid iterative reconstruction level in pediatric body CT. , 2014, AJR. American journal of roentgenology.