Evaluation of thermal comfort in galatsi arena of the olympics ?Athens 2004? using a CFD model

Abstract A computational fluid dynamics (CFD) model was used to evaluate the thermal comfort conditions in the indoor stadium of the Galatsi Arena, which hosted the sports of rhythmic gymnastics and table tennis during the Olympic Games “Athens 2004”. The CFD code CFX was applied to calculate the 3D airflow and temperature fields in the Arena for various values of temperatures (Tin) of conditioned inlet air. Calculated mean velocities and temperatures were used to determine the thermal comfort indices predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD) and to evaluate the thermal conditions in the various regions of the Arena. Calculated PMV and PPD values showed that thermal conditions in the Galatsi Arena were very satisfactory for Tin = 16 °C; only a small percentage (

[1]  Vice President,et al.  AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS INC. , 2007 .

[2]  O. I. Stathopoulou,et al.  Indoor air quality in a dentistry clinic. , 2007, The Science of the total environment.

[3]  Johan Meyers,et al.  Combining CFD and data-based mechanistic (DBM) modelling approaches , 2004 .

[4]  Wan Ki Chow Numerical studies of airflows induced by mechanical ventilation and air-conditioning (MVAC) systems , 2001 .

[5]  Wong Nyuk Hien,et al.  Effects of double glazed facade on energy consumption, thermal comfort and condensation for a typical office building in Singapore , 2005 .

[6]  Zhiqiang John Zhai,et al.  Sensitivity analysis and application guides for integrated building energy and CFD simulation , 2006 .

[7]  F. Menter Two-equation eddy-viscosity turbulence models for engineering applications , 1994 .

[8]  Mats Sandberg,et al.  Investigation of air quality, comfort parameters and effectiveness for two floor-level air supply systems in classrooms , 2007 .

[9]  Kifle G. Gebremedhin,et al.  Characterization of flow field in a ventilated space and simulation of heat exchange between cows and their environment , 2003 .

[10]  D. Wilcox Reassessment of the scale-determining equation for advanced turbulence models , 1988 .

[11]  Shuzo Murakami,et al.  Two-step optimal design method using genetic algorithms and CFD-coupled simulation for indoor thermal environments , 2007 .

[12]  Chris T. Kiranoudis,et al.  Computational analysis of thermal comfort: the case of the archaeological museum of Athens , 2000 .

[13]  Bahram Moshfegh,et al.  Numerical predictions of indoor climate in large industrial premises. A comparison between different k–ε models supported by field measurements , 2007 .

[14]  A.M.O. Smith,et al.  Turbulence models and their application in hydraulics: W. Rodi, University of Karlsruhe, International Association for Hydraulic Research, Rotterdamseweg 185, 2600 MH Delft, The Netherlands , 1981 .

[15]  A. Hwang [Thermal comfort]. , 1990, Taehan kanho. The Korean nurse.

[16]  P. Bradshaw,et al.  Turbulence Models and Their Application in Hydraulics. By W. RODI. International Association for Hydraulic Research, Delft, 1980. Paperback US $15. , 1983, Journal of Fluid Mechanics.

[17]  Francis W.H. Yik,et al.  Locating air-conditioners and furniture inside residential flats to obtain good thermal comfort , 2002 .

[18]  Anastasios I. Stamou,et al.  Verification of a CFD model for indoor airflow and heat transfer , 2006 .

[19]  E Ery Djunaedy,et al.  Thermal comfort study of an air-conditioned lecture theatre in the tropics , 2003 .