Epidermal devices for noninvasive, precise, and continuous mapping of macrovascular and microvascular blood flow

Advances in ultrathin, skin-like electronics lead to wearable devices for continuous, noninvasive blood flow monitoring. Continuous monitoring of variations in blood flow is vital in assessing the status of microvascular and macrovascular beds for a wide range of clinical and research scenarios. Although a variety of techniques exist, most require complete immobilization of the subject, thereby limiting their utility to hospital or clinical settings. Those that can be rendered in wearable formats suffer from limited accuracy, motion artifacts, and other shortcomings that follow from an inability to achieve intimate, noninvasive mechanical linkage of sensors with the surface of the skin. We introduce an ultrathin, soft, skin-conforming sensor technology that offers advanced capabilities in continuous and precise blood flow mapping. Systematic work establishes a set of experimental procedures and theoretical models for quantitative measurements and guidelines in design and operation. Experimental studies on human subjects, including validation with measurements performed using state-of-the-art clinical techniques, demonstrate sensitive and accurate assessment of both macrovascular and microvascular flow under a range of physiological conditions. Refined operational modes eliminate long-term drifts and reduce power consumption, thereby providing steps toward the use of this technology for continuous monitoring during daily activities.

[1]  W. R. Tompkins,et al.  On-line measurement of microvascular dimensions by television microscopy. , 1972, Journal of applied physiology.

[2]  Zhibin Yu,et al.  User-interactive electronic skin for instantaneous pressure visualization. , 2013, Nature materials.

[3]  G. Nilsson,et al.  Laser Doppler perfusion imaging by dynamic light scattering , 1993, IEEE Transactions on Biomedical Engineering.

[4]  H Harry Asada,et al.  Mobile monitoring with wearable photoplethysmographic biosensors. , 2003, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[5]  Yewang Su,et al.  Mechanics of Epidermal Electronics , 2012 .

[6]  Harvey N Mayrovitz,et al.  Inspiration-induced vascular responses in finger dorsum skin. , 2002, Microvascular research.

[7]  P. Sheet,et al.  Laser Doppler flowmetry. , 1990, Journal of medical engineering & technology.

[8]  Amir Lerman,et al.  The Assessment of Endothelial Function: From Research Into Clinical Practice , 2012, Circulation.

[9]  S Meiman,et al.  A detailed analysis of charges for hematopoietic stem cell transplantation at a children’s hospital , 1998, Bone Marrow Transplantation.

[10]  Ton van Leeuwen,et al.  Review of laser speckle contrast techniques for visualizing tissue perfusion , 2008, Lasers in Medical Science.

[11]  R. Draijer,et al.  Non-invasive methods and stimuli for evaluating the skin's microcirculation. , 2006, Journal of pharmacological and toxicological methods.

[12]  John A. Rogers,et al.  Thermal Transport Characteristics of Human Skin Measured In Vivo Using Ultrathin Conformal Arrays of Thermal Sensors and Actuators , 2015, PloS one.

[13]  K. Lomas,et al.  A computer model of human thermoregulation for a wide range of environmental conditions: the passive system. , 1999, Journal of applied physiology.

[14]  Jerrold Scott Petrofsky,et al.  Resting Blood Flow in the Skin: Does it Exist, and What is the Influence of Temperature, Aging, and Diabetes? , 2012, Journal of diabetes science and technology.

[15]  Benjamin C. K. Tee,et al.  Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring , 2013, Nature Communications.

[16]  Y. Mahler,et al.  Theoretical analysis of the transient thermal clearance method for regional blood flow measurement , 1986, Medical and Biological Engineering and Computing.

[17]  R. Jain,et al.  Microvascular architecture in a mammary carcinoma: branching patterns and vessel dimensions. , 1991, Cancer research.

[18]  Jonathan R. Lindner,et al.  Microbubbles in medical imaging: current applications and future directions , 2004, Nature Reviews Drug Discovery.

[19]  D. Delpy,et al.  Thermal clearance blood flow sensor—sensitivity, linearity and flow depth discrimination , 1989, Medical and Biological Engineering and Computing.

[20]  D. Webb,et al.  Venous occlusion plethysmography in cardiovascular research: methodology and clinical applications. , 2001, British journal of clinical pharmacology.

[21]  V. C. Roberts,et al.  Simultaneous measurement of skin blood flow by the transient thermal-clearance method and laser Doppler flowmetry , 1988, Medical and Biological Engineering and Computing.

[22]  A. Caduff,et al.  A wearable diffuse reflectance sensor for continuous monitoring of cutaneous blood content , 2009, Physics in medicine and biology.

[23]  V L Newhouse,et al.  Second harmonic ultrasonic blood perfusion measurement. , 1993, Ultrasound in medicine & biology.

[24]  Win-Li Lin,et al.  Effect of effective tissue conductivity on thermal dose distributions of living tissue with directional blood flow during thermal therapy , 2002 .

[25]  D. Boas,et al.  Laser speckle contrast imaging in biomedical optics. , 2010, Journal of biomedical optics.

[26]  Gert E. Nilsson,et al.  Evaluation of a Laser Doppler Flowmeter for Measurement of Tissue Blood Flow , 1980, IEEE Transactions on Biomedical Engineering.

[27]  Adam Bush,et al.  Peripheral Vasoconstriction and Abnormal Parasympathetic Response to Sighs and Transient Hypoxia in Sickle Cell Disease at a Glance Commentary , 2022 .

[28]  L S Murray,et al.  How reproducible is bilateral forearm plethysmography? , 1998, British journal of clinical pharmacology.

[29]  Yonggang Huang,et al.  Ultrathin conformal devices for precise and continuous thermal characterization of human skin. , 2013, Nature materials.

[30]  Jung Woo Lee,et al.  Rugged and breathable forms of stretchable electronics with adherent composite substrates for transcutaneous monitoring , 2014, Nature Communications.

[31]  Alan Murray,et al.  Microvascular blood flow and skin temperature changes in the fingers following a deep nspiratory gasp. , 2002, Physiological measurement.

[32]  A. Stefanovska,et al.  Low-frequency oscillations of the laser Doppler perfusion signal in human skin. , 2006, Microvascular research.

[33]  M. Kaltenbrunner,et al.  An Imperceptible Plastic Electronic Wrap , 2014, Advanced materials.

[34]  Renshi Sawada,et al.  An integrated laser blood flowmeter , 2003 .

[35]  Yonggang Huang,et al.  Materials and Mechanics for Stretchable Electronics , 2010, Science.

[36]  M. Moskowitz,et al.  Dynamic Imaging of Cerebral Blood Flow Using Laser Speckle , 2001, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[37]  Osamu Tochikubo,et al.  Measurement of hemodynamics during postural changes using a new wearable cephalic laser blood flowmeter. , 2009, Circulation journal : official journal of the Japanese Circulation Society.

[38]  Jing Liu,et al.  A feasible method for measuring the blood flow velocity in superficial artery based on the laser induced dynamic thermography , 2012 .

[39]  M. Kaltenbrunner,et al.  An ultra-lightweight design for imperceptible plastic electronics , 2013, Nature.

[40]  Oberg Pa,et al.  Laser-Doppler flowmetry. , 1990, Critical reviews in biomedical engineering.

[41]  Janice K Popp,et al.  Health Problems Associated with International Business Travel , 2000, AAOHN journal : official journal of the American Association of Occupational Health Nurses.

[42]  G. Kleinrensink,et al.  Perforating veins: an anatomical approach to arteriovenous fistula performance in the forearm. , 2011, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[43]  Raeed H. Chowdhury,et al.  Epidermal Electronics , 2011, Science.

[44]  A. Brakkee,et al.  Measurements of the thermal conductivity of the skin as an indication of skin blood flow. , 1968, The Journal of investigative dermatology.

[45]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[46]  R. Close,et al.  X-ray videodensitometric methods for blood flow and velocity measurement: a critical review of literature. , 2000, Medical physics.