Practical spread spectrum pulse compression for ultrasonic tissue imaging

Spread spectrum pulse compression is a signal processing algorithm that enhances critical system performance parameters such as signal-to-noise ratio, peak power requirements, minimum detectable signal, and total dynamic range. For this research, a digital, real-time, Barker coded, bi-phase modulator was designed and constructed, as well as a simple ultrasonic test tank containing both synthetic targets and excised goat's liver. Upon reception and demodulation of the spread spectrum ultrasonic echo, cross-correlation with a sidelobe suppression filter was performed. Due to limitations such as narrow bandwidth, and very short minimum ranges, a practical ultrasonic pulse compression system must be restricted to short code lengths. For 13 bit Barker code compression, the expected increase in signal-to-noise ratio of 11 dB was realized; at the same time greater than 30 dB of instantaneous dynamic range was maintained.

[1]  Rodger E. Ziemer,et al.  Principles of communications , 1976 .

[2]  P. King Medical imaging systems , 1986, Proceedings of the IEEE.

[3]  N A Rao,et al.  Experimental point spread function of fm pulse imaging scheme. , 1995, Ultrasonic imaging.

[4]  L. R. Welch Pulse compression ultrasound for minimization of transmitted peak power , 1994, Proceedings of 1994 20th Annual Northeast Bioengineering Conference.

[5]  W. H. Chen,et al.  Ultrasonic non-destructive testing using Barker code pulse compression techniques , 1988 .

[6]  C. K. Yuen,et al.  Theory and Application of Digital Signal Processing , 1978, IEEE Transactions on Systems, Man, and Cybernetics.

[7]  F.F. Kretschmer,et al.  A New Class of Polyphase Pulse Compression Codes and Techniques , 1981, IEEE Transactions on Aerospace and Electronic Systems.

[8]  F. Harris On the use of windows for harmonic analysis with the discrete Fourier transform , 1978, Proceedings of the IEEE.

[9]  M. O'Donnell,et al.  Coded excitation system for improving the penetration of real-time phased-array imaging systems , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  Martin H. Ackroyd,et al.  Optimum Mismatched Filters for Sidelobe Suppression , 1973, IEEE Transactions on Aerospace and Electronic Systems.

[11]  V. Reddy,et al.  Biphase Sequence Generation with Low Sidelobe Autocorrelation Function , 1986, IEEE Transactions on Aerospace and Electronic Systems.

[12]  Ronald A. Roy,et al.  Acoustic cavitation produced by microsecond pulses of ultrasound: a discussion of some selected results. , 1992, The Journal of the Acoustical Society of America.

[13]  John Michael Baden,et al.  Biphase codes with minimum peak sidelobes , 1989, Proceedings of the IEEE National Radar Conference.