Arthroplasties (with and without bone cement) for proximal femoral fractures in adults.
暂无分享,去创建一个
BACKGROUND
Numerous types of arthroplasties may be used in the surgical treatment of a hip fracture (proximal femoral fracture). The main differences between the implants are in the design of the stems, whether the stem is cemented or uncemented, whether a second articulating joint is included within the prosthesis (bipolar prosthesis), or whether a partial (hemiarthroplasty) or total whole hip replacement is used.
OBJECTIVES
To review all randomised controlled trials comparing different arthroplasties for the treatment of hip fractures in adults.
SEARCH STRATEGY
We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (September 2009), CENTRAL (The Cochrane Library 2009, Issue 3), MEDLINE, EMBASE and trial registers (all to September 2009), and reference lists of articles.
SELECTION CRITERIA
All randomised and quasi-randomised controlled trials comparing different arthroplasties and their insertion with or without cement, for the treatment of hip fractures.
DATA COLLECTION AND ANALYSIS
Two review authors independently assessed trial quality, by use of a 10-item checklist, and extracted data.
MAIN RESULTS
Twenty-three trials involving 2861 older and mainly female patients with proximal femoral fractures are included. Cemented prostheses, when compared with uncemented prostheses (6 trials, 899 participants) were associated with a less pain at a year or later and improved mobility. No significant difference in surgical complications was found. One trial of 220 participants compared a hydroxyapatite coated hemiarthroplasty with a cemented prosthesis and reported no notable differences between the two prosthesis. Comparison of unipolar hemiarthroplasty with bipolar hemiarthroplasty (7 trials, 857 participants, 863 fractures) showed no significant differences between the two types of implant. Seven trials involving 734 participants compared hemiarthroplasty with a total hip replacement (THR). Most studies involved cemented implants. Dislocation of the prosthesis was more common with the THR but there was a general trend within these studies to better functional outcome scores for those treated with the THR.
AUTHORS' CONCLUSIONS
There is good evidence that cementing the prostheses in place will reduce post-operative pain and lead to better mobility. From the trials to date there is no evidence of any difference in outcome between bipolar and unipolar prosthesis. There is some evidence that a total hip replacement leads to better functional outcome than a hemiarthroplasty. Further well-conducted randomised trials are required.
[1] D. Altman,et al. Measuring inconsistency in meta-analyses , 2003, BMJ : British Medical Journal.
[2] F. Thompson. Two and a half years' experience with a vitallium intramedullary hip prosthesis. , 1954, The Journal of bone and joint surgery. American volume.
[3] A. Moore. METAL HIP JOINT: A NEW SELF-LOCKING VITALLIUM PROSTHESIS , 1952, Southern medical journal.