Single-image phase retrieval for hard X-ray grating interferometry.

A single-image method is proposed for quantitative phase retrieval in hard X-ray grating interferometry. This novel method assumes a quasi-homogeneous sample, with a constant ratio between the real and imaginary parts of its complex refractive index. The method is first theoretically derived and presented, and then validated by synchrotron radiation experiments. Compared with the phase-stepping method, the presented approach abandons grating scanning and multiple image acquisition, and is therefore advantageous in terms of its simplified acquisition procedure and reduced data-collection times, which are especially important for applications such as in vivo imaging and phase tomography. Moreover, the sample's phase image, instead of its first derivative, is directly retrieved. In particular, the stripe artifacts encountered in the integrated phase images are significantly suppressed. The improved quality of the retrieved phase images can be beneficial for image interpretation and subsequent processing. Owing to its requirement for a single image and its robustness against noise, the present method is expected to find use in potential investigations in diverse applications.

[1]  E. Pisano,et al.  Mass density images from the diffraction enhanced imaging technique. , 2005, Medical physics.

[2]  R. Ruth,et al.  X-ray phase-contrast tomography with a compact laser-driven synchrotron source , 2015, Proceedings of the National Academy of Sciences.

[3]  A. Snigirev,et al.  On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation , 1995 .

[4]  Miles N Wernick,et al.  Computation of mass-density images from x-ray refraction-angle images. , 2006, Physics in medicine and biology.

[5]  David M Paganin,et al.  Analyser-based mammography using single-image reconstruction. , 2005, Physics in medicine and biology.

[6]  Franz Pfeiffer,et al.  Multi-contrast 3D X-ray imaging of porous and composite materials , 2015 .

[7]  F. Pfeiffer,et al.  Hard X-ray phase-contrast tomography of non-homogeneous specimens: grating interferometry versus propagation-based imaging. , 2016, Journal of synchrotron radiation.

[8]  D. Paganin,et al.  2D and 3D X-ray phase retrieval of multi-material objects using a single defocus distance. , 2010, Optics express.

[9]  Paola Coan,et al.  X-ray phase-contrast imaging: from pre-clinical applications towards clinics , 2013, Physics in medicine and biology.

[10]  Luigi Rigon,et al.  A three-image algorithm for hard x-ray grating interferometry. , 2013, Optics express.

[11]  Marco Endrizzi,et al.  Edge illumination X-ray phase tomography of multi-material samples using a single-image phase retrieval algorithm. , 2017, Optics express.

[12]  Marco Stampanoni,et al.  Non-invasive classification of microcalcifications with phase-contrast X-ray mammography , 2014, Nature Communications.

[13]  B. L. Henke,et al.  X-Ray Interactions: Photoabsorption, Scattering, Transmission, and Reflection at E = 50-30,000 eV, Z = 1-92 , 1993 .

[14]  Erik L. G. Wernersson,et al.  Postprocessing method for reducing phase effects in reconstructed microcomputed-tomography data. , 2013, Journal of the Optical Society of America. A, Optics, image science, and vision.

[15]  T. Weitkamp,et al.  ANKAphase: software for single-distance phase retrieval from inline X-ray phase-contrast radiographs. , 2011, Journal of synchrotron radiation.

[16]  M. Stampanoni,et al.  Amyloid-β plaque deposition measured using propagation-based X-ray phase contrast CT imaging , 2016, Journal of synchrotron radiation.

[17]  Chidane Ouchi,et al.  Two-dimensional gratings-based phase-contrast imaging using a conventional x-ray tube. , 2011, Optics letters.

[18]  Charlotte K. Hagen,et al.  Single-image phase retrieval using an edge illumination X-ray phase-contrast imaging setup , 2015, Journal of synchrotron radiation.

[19]  Atsushi Momose,et al.  Four-dimensional X-ray phase tomography with Talbot interferometry and white synchrotron radiation: dynamic observation of a living worm. , 2011, Optics express.

[20]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[21]  Timur E. Gureyev,et al.  Linear systems with slowly varying transfer functions and their application to x-ray phase-contrast imaging , 2004 .

[22]  Ziyu Wu,et al.  X-ray phase radiography and tomography with grating interferometry and the reverse projection technique , 2013 .

[23]  Michael Unser,et al.  Joint absorption and phase retrieval in grating-based x-ray radiography. , 2016, Optics express.

[24]  Two dimensional x-ray phase imaging using single grating interferometer with embedded x-ray targets. , 2015, Optics express.

[25]  S. Wilkins,et al.  Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object , 2002, Journal of microscopy.

[26]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[27]  Ziyu Wu,et al.  Single-shot x-ray phase imaging with grating interferometry and photon-counting detectors. , 2014, Optics letters.

[28]  Atsushi Momose,et al.  High-speed X-ray phase imaging and X-ray phase tomography with Talbot interferometer and white synchrotron radiation. , 2009, Optics express.

[29]  Ke Li,et al.  Grating based x-ray differential phase contrast imaging without mechanical phase stepping. , 2014, Optics express.

[30]  O. Bunk,et al.  A two-directional approach for grating based differential phase contrast imaging using hard x-rays. , 2007, Optics express.

[31]  T Salditt,et al.  Phase-contrast x-ray imaging and tomography of the nematode Caenorhabditis elegans , 2012, Physics in medicine and biology.

[32]  Peter Modregger,et al.  Non-linear regularized phase retrieval for unidirectional X-ray differential phase contrast radiography. , 2011, Optics express.