Tailor‐made surgical guide based on rapid prototyping technique for cup insertion in total hip arthroplasty

A surgical guide made by the rapid prototyping (RP) technique for cup insertion in total hip arthroplasty might be useful to avoid malalignment of the cup, which indicates postoperative complications.

[1]  Hideki Yoshikawa,et al.  Comparison of navigation accuracy in THA between the mini‐anterior and ‐posterior approaches , 2009, The international journal of medical robotics + computer assisted surgery : MRCAS.

[2]  H. Yoshikawa,et al.  Three-dimensional corrective osteotomy of malunited fractures of the upper extremity with use of a computer simulation system. , 2008, The Journal of bone and joint surgery. American volume.

[3]  R. Richards,et al.  Analysis of cover of the femoral head in normal and dysplastic hips: new CT-based technique. , 2008, The Journal of bone and joint surgery. British volume.

[4]  M. Strauss,et al.  Evaluation of the accuracy of three different computer-aided surgery systems in dental implantology: optical tracking vs. stereolithographic splint systems. , 2008, Clinical oral implants research.

[5]  Hideki Yoshikawa,et al.  Corrective osteotomy for malunited intra-articular fracture of the distal radius using a custom-made surgical guide based on three-dimensional computer simulation: case report. , 2008, The Journal of hand surgery.

[6]  Hideki Yoshikawa,et al.  Preoperative templating of femoral components on plain X-rays , 2007, Archives of Orthopaedic and Trauma Surgery.

[7]  T Nishii,et al.  Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation. , 2007, The Journal of bone and joint surgery. British volume.

[8]  J. Argenson,et al.  Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. A prospective, randomized, controlled study. , 2007, The Journal of bone and joint surgery. American volume.

[9]  C. Verheyen,et al.  Poor accuracy of freehand cup positioning during total hip arthroplasty , 2007, Archives of Orthopaedic and Trauma Surgery.

[10]  Moritz Tannast,et al.  THA Performed using Conventional and Navigated Tissue-preserving Techniques , 2006, Clinical orthopaedics and related research.

[11]  F M Rodriguez y Baena,et al.  Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. , 2006, The Journal of bone and joint surgery. British volume.

[12]  Lars Perlick,et al.  Position of the acetabular cup -- accuracy of radiographic calculation compared to CT-based measurement. , 2006, European journal of radiology.

[13]  B B Seedhom,et al.  Computer-assisted Total Knee Arthroplasty Using Patient-specific Templating , 2006, Clinical orthopaedics and related research.

[14]  M Tingart,et al.  Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? , 2006, The Journal of bone and joint surgery. British volume.

[15]  Heinz Handels,et al.  Automatic atlas-based contour extraction of anatomical structures in medical images , 2005 .

[16]  S. Testelin,et al.  Comparison of two computer-assisted surgery techniques to guide a mandibular distraction osteogenesis procedure. Technical note. , 2005, International journal of oral and maxillofacial surgery.

[17]  Karl-Heinz Widmer,et al.  Joint replacement-total hip replacement with CT-based navigation. , 2004, Injury.

[18]  Hideki Yoshikawa,et al.  Measurements of Pelvic Flexion Angle Using Three-Dimensional Computed Tomography , 2003, Clinical orthopaedics and related research.

[19]  George A. Brown,et al.  Application of Computer-Generated Stereolithography and Interpositioning Template in Acetabular Fractures: A Report of Eight Cases , 2002, Journal of orthopaedic trauma.

[20]  Branislav Jaramaz,et al.  Comparison of a mechanical acetabular alignment guide with computer placement of the socket. , 2002, The Journal of arthroplasty.

[21]  A. Prescher,et al.  Computer-Assisted Orthopedic Surgery With Individual Templates and Comparison to Conventional Operation Method , 2001, Spine.

[22]  B Jaramaz,et al.  Image Guided Navigation System to Measure Intraoperatively Acetabular Implant Alignment , 1998, Clinical orthopaedics and related research.

[23]  K. Radermacher,et al.  Computer assisted orthopaedic surgery with image based individual templates. , 1998, Clinical orthopaedics and related research.

[24]  D. Murray The definition and measurement of acetabular orientation. , 1993, The Journal of bone and joint surgery. British volume.

[25]  William E. Lorensen,et al.  Marching cubes: A high resolution 3D surface construction algorithm , 1987, SIGGRAPH.

[26]  J. Lewis,et al.  Dislocations after total hip-replacement arthroplasties. , 1978, The Journal of bone and joint surgery. American volume.

[27]  D. Markel,et al.  Evaluation of component positioning in primary total hip arthroplasty using an imageless navigation device compared with traditional methods. , 2009, The Journal of arthroplasty.

[28]  K. Bozic,et al.  An overview of economic issues in computer-assisted total joint arthroplasty. , 2007, Clinical orthopaedics and related research.

[29]  Kunal Lal,et al.  Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part I. The concept. , 2006, Journal of prosthodontics : official journal of the American College of Prosthodontists.