Meshfree simulations of ultrasound vector flow imaging using smoothed particle hydrodynamics

Before embarking on a series of in vivo tests, design of ultrasound-flow-imaging modalities are generally more efficient through computational models as multiple configurations can be tested methodically. To that end, simulation models must generate realistic blood flow dynamics and Doppler signals. The current in silico ultrasound simulation techniques suffer mainly from uncertainty in providing accurate trajectories of moving ultrasound scatterers. In mesh-based Eulerian methods, numerical truncation errors from the interpolated velocities, both in the time and space dimensions, can accumulate significantly and make the pathlines unreliable. These errors can distort beam-to-beam inter-correlation present in ultrasound flow imaging. It is thus a technical issue to model a correct motion of the scatterers by considering their interaction with boundaries and neighboring scatterers. We hypothesized that in silico analysis of emerging ultrasonic imaging modalities can be implemented more accurately with meshfree approaches. We developed an original fluid-ultrasound simulation environment based on a meshfree Lagrangian CFD (computational fluid dynamics) formulation, which allows analysis of ultrasound flow imaging. This simulator combines smoothed particle hydrodynamics (SPH) and Fourier-domain linear acoustics (SIMUS  =  simulator for ultrasound imaging). With such a particle-based computation, the fluid particles also acted as individual ultrasound scatterers, resulting in a direct and physically sound fluid-ultrasonic coupling. We used the in-house algorithms for fluid and ultrasound simulations to simulate high-frame-rate vector flow imaging. The potential of the particle-based method was tested in 2D simulations of vector Doppler for the intracarotid flow. The Doppler-based velocity fields were compared with those issued from SPH. The numerical evaluations showed that the vector flow fields obtained by vector Doppler components were in good agreement with the original SPH velocities, with relative errors less than 10% and 2% in the cross-beam and axial directions, respectively. Our results showed that SPH-SIMUS coupling enables direct and realistic simulations of ultrasound flow imaging. The proposed coupled algorithm has also the advantage to be 3D compatible and parallelizable.

[1]  J. Morris,et al.  Modeling Low Reynolds Number Incompressible Flows Using SPH , 1997 .

[2]  Damien Garcia,et al.  Ultrasound Vector Flow Imaging: II: Parallel Systems. , 2016, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[3]  S Shahriari,et al.  Evaluation of shear stress accumulation on blood components in normal and dysfunctional bileaflet mechanical heart valves using smoothed particle hydrodynamics. , 2012, Journal of biomechanics.

[4]  Einar Heiberg,et al.  Vortex ring behavior provides the epigenetic blueprint for the human heart , 2016, Scientific Reports.

[5]  Franck Nicoud,et al.  Image-based large-eddy simulation in a realistic left heart , 2014 .

[6]  J W Hunt,et al.  A method for computer simulation of ultrasound Doppler color flow images--I. Theory and numerical method. , 1992, Ultrasound in medicine & biology.

[7]  Alfredo Goddi,et al.  High-frame rate vector flow imaging of the carotid bifurcation , 2017, Insights into Imaging.

[8]  M. De Craene,et al.  A Framework for the Generation of Realistic Synthetic Cardiac Ultrasound and Magnetic Resonance Imaging Sequences From the Same Virtual Patients , 2018, IEEE Transactions on Medical Imaging.

[9]  Olivier Basset,et al.  3D dynamic model of healthy and pathologic arteries for ultrasound technique evaluation. , 2008, Medical physics.

[10]  M. Fox Multiple crossed-beam ultrasound Doppler velocimetry , 1978 .

[11]  Damien Garcia,et al.  A fast all-in-one method for automated post-processing of PIV data , 2011, Experiments in fluids.

[12]  Gordon S. Kino,et al.  A theory for the radiation pattern of a narrow‐strip acoustic transducer , 1980 .

[13]  Daniel J. Price Smoothed particle hydrodynamics and magnetohydrodynamics q , 2010 .

[14]  J A Jensen,et al.  A model for the propagation and scattering of ultrasound in tissue. , 1991, The Journal of the Acoustical Society of America.

[15]  Jørgen Arendt Jensen,et al.  Computer Phantoms for Simulating Ultrasound B-Mode and CFM Images , 1997 .

[16]  Lasse Lovstakken,et al.  Shunt flow evaluation in congenital heart disease based on two-dimensional speckle tracking. , 2014, Ultrasound in medicine & biology.

[17]  Pheng-Ann Heng,et al.  A meshless rheological model for blood-vessel interaction in endovascular simulation. , 2010, Progress in biophysics and molecular biology.

[18]  J. Monaghan Smoothed Particle Hydrodynamics and Its Diverse Applications , 2012 .

[19]  H. Torp,et al.  Ultrasound simulation of complex flow velocity fields based on computational fluid dynamics , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  Billy Y S Yiu,et al.  Vector projectile imaging: time-resolved dynamic visualization of complex flow patterns. , 2014, Ultrasound in medicine & biology.

[21]  Richard S. C. Cobbold,et al.  A Stochastic Model of the Backscattered Doppler Ultrasound from Blood , 1986, IEEE Transactions on Biomedical Engineering.

[22]  I. Marshall,et al.  Comparative Study of Magnetic Resonance Imaging and Image-Based Computational Fluid Dynamics for Quantification of Pulsatile Flow in a Carotid Bifurcation Phantom , 2003, Annals of Biomedical Engineering.

[23]  Yuefan Deng,et al.  Particle-Based Methods for Multiscale Modeling of Blood Flow in the Circulation and in Devices: Challenges and Future Directions , 2010, Annals of Biomedical Engineering.

[24]  Damien Garcia,et al.  Doppler vortography: a color Doppler approach to quantification of intraventricular blood flow vortices. , 2014, Ultrasound in medicine & biology.

[25]  Piero Tortoli,et al.  Real-Time Blood Velocity Vector Measurement Over a 2-D Region , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[26]  Damien Garcia,et al.  Ultrasound Vector Flow Imaging: I: Sequential Systems. , 2016, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[27]  J. Jensen,et al.  A new method for estimation of velocity vectors , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[28]  Ibrahim Hassan,et al.  Modeling unsteady flow characteristics using smoothed particle hydrodynamics , 2013 .

[29]  Damien Garcia,et al.  Color and Vector Flow Imaging in Parallel Ultrasound With Sub-Nyquist Sampling , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[30]  Jan Vierendeels,et al.  A simulation environment for validating ultrasonic blood flow and vessel wall imaging based on fluid-structure interaction simulations: ultrasonic assessment of arterial distension and wall shear rate. , 2010, Medical physics.

[31]  W. Mao,et al.  Fully-coupled fluid-structure interaction simulation of the aortic and mitral valves in a realistic 3D left ventricle model , 2017, PloS one.

[32]  J. A. Jensen,et al.  Transverse flow imaging using synthetic aperture directional beamforming , 2002, 2002 IEEE Ultrasonics Symposium, 2002. Proceedings..

[33]  Guirong Liu,et al.  Smoothed Particle Hydrodynamics (SPH): an Overview and Recent Developments , 2010 .

[34]  Damien Garcia,et al.  Robust smoothing of gridded data in one and higher dimensions with missing values , 2010, Comput. Stat. Data Anal..

[35]  Damien Garcia,et al.  Energy loss index in aortic stenosis: from fluid mechanics concept to clinical application. , 2013, Circulation.

[36]  B T Cox,et al.  k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields. , 2010, Journal of biomedical optics.

[37]  R. Courant,et al.  On the Partial Difference Equations, of Mathematical Physics , 2015 .

[38]  Wei Sun,et al.  Modeling Left Ventricular Blood Flow Using Smoothed Particle Hydrodynamics , 2017, Cardiovascular engineering and technology.

[39]  L. Kadem,et al.  Chapter 11 – Smoothed Particle Hydrodynamics Method and Its Applications to Cardiovascular Flow Modeling , 2018 .

[40]  Damien Garcia,et al.  Corrigendum to "Robust smoothing of gridded data in one and higher dimensions with missing values" [Comput. Statist. Data Anal. 54 (2010) 1167-1178] , 2012, Comput. Stat. Data Anal..

[41]  Damien Garcia,et al.  Ultrasound Vector Flow Imaging—Part I: Sequential Systems , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[42]  Olivier Basset,et al.  CREANUIS: a non-linear radiofrequency ultrasound image simulator. , 2013, Ultrasound in medicine & biology.

[43]  Jeffrey S. Ovall The Laplacian and Mean and Extreme Values , 2016, Am. Math. Mon..

[44]  Damien Garcia,et al.  Ultrasound Vector Flow Imaging: II: Parallel Systems. , 2016, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[45]  J W Hunt,et al.  A method for computer simulation of ultrasound Doppler color flow images--II. Simulation results. , 1992, Ultrasound in medicine & biology.

[46]  Damien Garcia,et al.  Two-Dimensional Intraventricular Flow Mapping by Digital Processing Conventional Color-Doppler Echocardiography Images , 2010, IEEE Transactions on Medical Imaging.

[47]  Ingvild Kinn Ekroll,et al.  Robust angle-independent blood velocity estimation based on dual-angle plane wave imaging , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[48]  M S Patterson,et al.  Computer Simulations of Speckle in B-Scan Images , 1983, Ultrasonic imaging.

[49]  Lester W. Schmerr,et al.  Phased Array Beam Modeling (1-D Elements) , 2015 .

[50]  Franck Nicoud,et al.  Intraventricular vector flow mapping—a Doppler-based regularized problem with automatic model selection , 2017, Physics in medicine and biology.

[51]  P. Stepanishen Transient Radiation from Pistons in an Infinite Planar Baffle , 1970 .

[52]  G. Trahey,et al.  Angle Independent Ultrasonic Detection of Blood Flow , 1987, IEEE Transactions on Biomedical Engineering.

[53]  Wei Sun,et al.  Fluid–Structure Interaction Study of Transcatheter Aortic Valve Dynamics Using Smoothed Particle Hydrodynamics , 2016, Cardiovascular engineering and technology.

[54]  V. Springel Smoothed Particle Hydrodynamics in Astrophysics , 2010, 1109.2219.

[55]  G. Cloutier,et al.  A critical review and uniformized representation of statistical distributions modeling the ultrasound echo envelope. , 2010, Ultrasound in medicine & biology.

[56]  Christopher B. Kendall,et al.  Use of carotid ultrasound to identify subclinical vascular disease and evaluate cardiovascular disease risk: a consensus statement from the American Society of Echocardiography Carotid Intima-Media Thickness Task Force. Endorsed by the Society for Vascular Medicine. , 2008, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[57]  J. Monaghan Smoothed particle hydrodynamics , 2005 .

[58]  Yadong Li,et al.  A frequency domain model for generating B-mode images with array transducers , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[59]  C. Antoci,et al.  Numerical simulation of fluid-structure interaction by SPH , 2007 .

[60]  M. Fink,et al.  Ultrafast compound imaging for 2-D motion vector estimation: application to transient elastography , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[61]  B. Rogers,et al.  Smoothed particle hydrodynamics method applied to pulsatile flow inside a rigid two‐dimensional model of left heart cavity , 2012, International journal for numerical methods in biomedical engineering.