Long-range correlations of serial FEV1 measurements in emphysematous patients and normal subjects.

In obstructive lung disease the annual change in lung function is usually estimated from serial measurements of forced expiratory volume in 1 s (FEV1). Frequent measurements in each patient may not improve this estimate because data are not statistically independent; i.e., the measurements are autocorrelated. The purpose of this study was to describe the correlation structure in time series of FEV1 measurements. Nineteen patients with severe alpha1-antitrypsin deficiency (phenotype PiZ) and moderate to severe emphysema and two subjects with normal lungs were followed for several years with daily self-administered spirometry. FEV1 measurements fulfilling standard criteria were detrended, and the autocorrelation profile and the power spectrum were calculated. On average the subjects were followed for >3 yr and performed >1,000 acceptable spirometries. The autocorrelation of FEV1 measurements in the emphysematous patients was approximately 0.35 for short intervals and decreased almost exponentially with a half time of 38 days. Between 3 and 4 mo, the autocorrelation function became negative. It reached a minimum of -0.1 at approximately 8 mo and then increased toward zero over the following 12 mo. The autocorrelation function in the two normal subjects showed a similar pattern, but with a faster decay toward zero. In the patients, the power spectrum had a peak at 1 cycle/wk and showed a 1/f pattern, where f is frequency, with a slope of -0.88 at lower frequencies. We conclude that serial spirometric measurements show long-range correlations. The practical implication is that FEV1 need not be measured more often than once every 3 mo in studies of the long-term trends in lung function.

[1]  D. Cox,et al.  The Pi polymorphism: genetic, biochemical, and clinical aspects of human alpha 1-antitrypsin. , 1981, Advances in human genetics.

[2]  On modeling longitudinal pulmonary function data. , 1996, American journal of respiratory and critical care medicine.

[3]  A. Dirksen,et al.  Patient-administered sequential spirometry in healthy volunteers and patients with alpha 1-antitrypsin deficiency. , 1996, Respiratory medicine.

[4]  W. Stevenson,et al.  Patterns of beat-to-beat heart rate variability in advanced heart failure. , 1992, American heart journal.

[5]  P. Enright,et al.  Effect of effort on measurement of forced expiratory volume in one second. , 1987, The American review of respiratory disease.

[6]  A. Miller,et al.  Standardized lung function testing. , 1984, Bulletin europeen de physiopathologie respiratoire.

[7]  G. D'Alonzo,et al.  Measurements of morning and evening airflow grossly underestimate the circadian variability of FEV1 and peak expiratory flow rate in asthma. , 1995, American journal of respiratory and critical care medicine.

[8]  J. Ware,et al.  Statistical issues in longitudinal research on respiratory health. , 1996, American journal of respiratory and critical care medicine.

[9]  D. Cox,et al.  The Pi Polymorphism , 1981 .

[10]  T. Musha,et al.  1/f Fluctuation of Heartbeat Period , 1982, IEEE Transactions on Biomedical Engineering.

[11]  Bruce J. West,et al.  Chaos and fractals in human physiology. , 1990, Scientific American.

[12]  Richard F. Voss,et al.  Fractals in nature: from characterization to simulation , 1988 .

[13]  A. Buist Standardization of spirometry. , 1987, The American review of respiratory disease.

[14]  John L. Hankinson,et al.  Standardization of Spirometry, 1994 Update. American Thoracic Society. , 1995, American journal of respiratory and critical care medicine.

[15]  D J Marsh,et al.  1/f fluctuations in arterial pressure and regulation of renal blood flow in dogs. , 1990, The American journal of physiology.

[16]  Fagerhol Mk,et al.  The Pi polymorphism: genetic, biochemical, and clinical aspects of human alpha 1-antitrypsin. , 1981 .

[17]  J. Miller,et al.  Decreased heart rate variability and its association with increased mortality after acute myocardial infarction. , 1987, The American journal of cardiology.

[18]  P. Barnes,et al.  Circadian variation in airway function. , 1985, The American journal of medicine.

[19]  A. Coates,et al.  Sources of variation in FEV1. , 1994, American journal of respiratory and critical care medicine.

[20]  J. Roca,et al.  Standardization of the measurement of transfer factor (diffusing capacity) , 1993, European Respiratory Journal.

[21]  A. Dirksen,et al.  Long-term performance of a hand held spirometer. , 1996, Thorax.

[22]  Buist As Standardization of spirometry. , 1987 .

[23]  M. Hetzel The pulmonary clock. , 1981, Thorax.

[24]  J. Ware,et al.  Overview of issues in the longitudinal analysis of respiratory data. , 1996, American journal of respiratory and critical care medicine.

[25]  J E Cotes,et al.  Lung volumes and forced ventilatory flows , 1993, European Respiratory Journal.

[26]  D. Dockery,et al.  Acute respiratory effects of particulate air pollution. , 1994, Annual review of public health.

[27]  D. Dockery,et al.  Longitudinal studies of air pollution effects on lung function. , 1996, American journal of respiratory and critical care medicine.