Spectral calibration of hyperspectral imagery using atmospheric absorption features.

One of the initial steps in the preprocessing of remote sensing data is the atmospheric correction of the at-sensor radiance images, i.e., radiances recorded at the sensor aperture. Apart from the accuracy in the estimation of the concentrations of the main atmospheric species, the retrieved surface reflectance is also influenced by the spectral calibration of the sensor, especially in those wavelengths mostly affected by gaseous absorptions. In particular, errors in the surface reflectance appear when a systematic shift in the nominal channel positions occurs. A method to assess the spectral calibration of hyperspectral imaging spectrometers from the acquired imagery is presented in this paper. The fundamental basis of the method is the calculation of the value of the spectral shift that minimizes the error in the estimates of surface reflectance. This is performed by an optimization procedure that minimizes the deviation between a surface reflectance spectrum and a smoothed one resulting from the application of a low-pass filter. A sensitivity analysis was performed using synthetic data generated with the MODTRAN4 radiative transfer code for several values of the spectral shift and the water vapor column content. The error detected in the retrieval is less than +/- 0.2 nm for spectral shifts smaller than 2 nm, and less than +/- 1.0 nm for extreme spectral shifts of 5 nm. A low sensitivity to uncertainties in the estimation of water vapor content was found, which reinforces the robustness of the algorithm. The method was successfully applied to data acquired by different hyperspectral sensors.

[1]  Yoram J. Kaufman,et al.  The atmospheric effect on the separability of field classes measured from satellites , 1985 .

[2]  M. S. Moran,et al.  Reflectance- and radiance-based methods for the in-flight absolute calibration of multispectral sensors , 1987 .

[3]  E. Vermote,et al.  SPOT calibration at the La Crau test site (France) , 1992 .

[4]  J. Conel,et al.  Recovery of atmospheric water vapor total column abundance from imaging spectrometer data around 940 nm - Sensitivity analysis and application to Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data , 1993 .

[5]  Kurtis J. Thome,et al.  Reflectance- and Irradiance-Based Calibration of Landsat-5 Thematic Mapper , 1997 .

[6]  R. Richter On the in-flight absolute calibration of high spatial resolution spaceborne sensors using small ground targets , 1997 .

[7]  Jessica A. Faust,et al.  Imaging Spectroscopy and the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) , 1998 .

[8]  R. Richter,et al.  Correction of satellite imagery over mountainous terrain. , 1998, Applied optics.

[9]  R. Green,et al.  Spectral calibration requirement for Earth-looking imaging spectrometers in the solar-reflected spectrum. , 1998, Applied optics.

[10]  Daniel Schläpfer,et al.  Atmospheric Precorrected Differential Absorption Technique to Retrieve Columnar Water Vapor , 1998 .

[11]  R. Jenssen,et al.  1 THE HYMAP TM AIRBORNE HYPERSPECTRAL SENSOR : THE SYSTEM , CALIBRATION AND PERFORMANCE , 1998 .

[12]  Peter Gege,et al.  System analysis and performance of the new version of the imaging spectrometer ROSIS , 1998 .

[13]  D. C. Robertson,et al.  MODTRAN cloud and multiple scattering upgrades with application to AVIRIS , 1998 .

[14]  P Mouroulis,et al.  Design of pushbroom imaging spectrometers for optimum recovery of spectroscopic and spatial information. , 2000, Applied optics.

[15]  R. Richter,et al.  Geo-atmospheric processing of airborne imaging spectrometry data. Part 2: Atmospheric/topographic correction , 2002 .

[16]  Robert O. Green,et al.  On-orbit radiometric and spectral calibration characteristics of EO-1 Hyperion derived with an underflight of AVIRIS and in situ measurements at Salar de Arizaro, Argentina , 2003, IEEE Trans. Geosci. Remote. Sens..

[17]  Zheng Qu,et al.  HATCH: results from simulated radiances, AVIRIS and Hyperion , 2003, IEEE Trans. Geosci. Remote. Sens..

[18]  Marcos J. Montes,et al.  Refinement of wavelength calibrations of hyperspectral imaging data using a spectrum-matching technique , 2004 .

[19]  Stefano Tarantola,et al.  Sensitivity Analysis in Practice: A Guide to Assessing Scientific Models , 2004 .

[20]  Frederic Teston,et al.  The PROBA/CHRIS mission: a low-cost smallsat for hyperspectral multiangle observations of the Earth surface and atmosphere , 2004, IEEE Transactions on Geoscience and Remote Sensing.