Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms.

CONTEXT Improving the function of prosthetic arms remains a challenge, because access to the neural-control information for the arm is lost during amputation. A surgical technique called targeted muscle reinnervation (TMR) transfers residual arm nerves to alternative muscle sites. After reinnervation, these target muscles produce electromyogram (EMG) signals on the surface of the skin that can be measured and used to control prosthetic arms. OBJECTIVE To assess the performance of patients with upper-limb amputation who had undergone TMR surgery, using a pattern-recognition algorithm to decode EMG signals and control prosthetic-arm motions. DESIGN, SETTING, AND PARTICIPANTS Study conducted between January 2007 and January 2008 at the Rehabilitation Institute of Chicago among 5 patients with shoulder-disarticulation or transhumeral amputations who underwent TMR surgery between February 2002 and October 2006 and 5 control participants without amputation. Surface EMG signals were recorded from all participants and decoded using a pattern-recognition algorithm. The decoding program controlled the movement of a virtual prosthetic arm. All participants were instructed to perform various arm movements, and their abilities to control the virtual prosthetic arm were measured. In addition, TMR patients used the same control system to operate advanced arm prosthesis prototypes. MAIN OUTCOME MEASURE Performance metrics measured during virtual arm movements included motion selection time, motion completion time, and motion completion ("success") rate. RESULTS The TMR patients were able to repeatedly perform 10 different elbow, wrist, and hand motions with the virtual prosthetic arm. For these patients, the mean motion selection and motion completion times for elbow and wrist movements were 0.22 seconds (SD, 0.06) and 1.29 seconds (SD, 0.15), respectively. These times were 0.06 seconds and 0.21 seconds longer than the mean times for control participants. For TMR patients, the mean motion selection and motion completion times for hand-grasp patterns were 0.38 seconds (SD, 0.12) and 1.54 seconds (SD, 0.27), respectively. These patients successfully completed a mean of 96.3% (SD, 3.8) of elbow and wrist movements and 86.9% (SD, 13.9) of hand movements within 5 seconds, compared with 100% (SD, 0) and 96.7% (SD, 4.7) completed by controls. Three of the patients were able to demonstrate the use of this control system in advanced prostheses, including motorized shoulders, elbows, wrists, and hands. CONCLUSION These results suggest that reinnervated muscles can produce sufficient EMG information for real-time control of advanced artificial arms.

[1]  David G. Stork,et al.  Pattern Classification , 1973 .

[2]  David J. Edell,et al.  A Peripheral Nerve Information Transducer for Amputees: Long-Term Multichannel Recordings from Rabbit Peripheral Nerves , 1986, IEEE Transactions on Biomedical Engineering.

[3]  R. Scott,et al.  Myoelectric control of prostheses. , 1986, Critical reviews in biomedical engineering.

[4]  G. Hefftner,et al.  The electromyogram (EMG) as a control signal for functional neuromuscular stimulation. I. Autoregressive modeling as a means of EMG signature discrimination , 1988, IEEE Transactions on Biomedical Engineering.

[5]  R.N. Scott,et al.  A new strategy for multifunction myoelectric control , 1993, IEEE Transactions on Biomedical Engineering.

[6]  J A Hoffer,et al.  Restoration of use of paralyzed limb muscles using sensory nerve signals for state control of FES-assisted walking. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[7]  David G. Stork,et al.  Pattern Classification (2nd ed.) , 1999 .

[8]  Philip R. Troyk,et al.  Implantable myoelectric sensors (IMES) for upper-extremity prosthesis control- preliminary work , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[9]  Kevin Englehart,et al.  Continuous multifunction myoelectric control using pattern recognition , 2003 .

[10]  Kevin B. Englehart,et al.  A robust, real-time control scheme for multifunction myoelectric control , 2003, IEEE Transactions on Biomedical Engineering.

[11]  Todd A. Kuiken,et al.  Consideration of nerve-muscle grafts to improve the control of artificial arms , 2003 .

[12]  Robert D. Lipschutz,et al.  The use of targeted muscle reinnervation for improved myoelectric prosthesis control in a bilateral shoulder disarticulation amputee , 2004, Prosthetics and orthotics international.

[13]  Eduardo Fernández,et al.  Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve , 2004, IEEE Transactions on Biomedical Engineering.

[14]  R.Fff. Weir,et al.  A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthesis control , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[15]  B. Hudgins,et al.  REAL-TIME MYOELECTRIC CONTROL IN A VIRTUAL ENVIRONMENT TO RELATE USABILITY VS. ACCURACY , 2005 .

[16]  Adrian D. C. Chan,et al.  A Gaussian mixture model based classification scheme for myoelectric control of powered upper limb prostheses , 2005, IEEE Transactions on Biomedical Engineering.

[17]  Robert D. Lipschutz,et al.  Improved Myoelectric Prosthesis Control Accomplished Using Multiple Nerve Transfers , 2006, Plastic and reconstructive surgery.

[18]  Dario Farina,et al.  Interpretation of the Surface Electromyogram in Dynamic Contractions , 2006, Exercise and sport sciences reviews.

[19]  T. Kuiken Targeted reinnervation for improved prosthetic function. , 2006, Physical Medicine and Rehabilitation Clinics of North America.

[20]  Ping Zhou,et al.  Decoding a new neural machine interface for control of artificial limbs. , 2007, Journal of neurophysiology.

[21]  Blair A. Lock,et al.  Redirection of cutaneous sensation from the hand to the chest skin of human amputees with targeted reinnervation , 2007, Proceedings of the National Academy of Sciences.

[22]  Robert D. Lipschutz,et al.  Targeted reinnervation for enhanced prosthetic arm function in a woman with a proximal amputation: a case study , 2007, The Lancet.

[23]  He Huang,et al.  An Analysis of EMG Electrode Configuration for Targeted Muscle Reinnervation Based Neural Machine Interface , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[24]  Robert D. Lipschutz,et al.  Targeted reinnervation to improve prosthesis control in transhumeral amputees. A report of three cases. , 2008, The Journal of bone and joint surgery. American volume.