Comparison of the QCM and the SPR method for surface studies and immunological applications

A comparison between the quartz-crystal microbalance (QCM) and surface plasmon resonance (SPR) using an especially designed flow-through cell for simultaneous measurements and flow-injection analysis (FIA) is presented. We compare the effects due to unspecific binding of bovine serum albumin (BSA) to gold surfaces, specific binding between BSA and monoclonal antibodies, regeneration experiments, serum experiments with HIV antigens and the influence of the bulk properties of liquid samples. The basic theory and its consequences on measurement signals and experimental methods are discussed. The fundamental problem of the comparability of different measurement principles is considered. We suggest guide parameters, which allow an objective judgement of the performance. We do not find any advantage of one particular system concerning sensitivity and cross sensitivity.

[1]  W. Lukosz,et al.  Principles and sensitivities of integrated optical and surface plasmon sensors for direct affinity sensing and immunosensing , 1991 .

[2]  D. Altschuh,et al.  Mapping of viral epitopes with conformationally specific monoclonal antibodies using biosensor technology. , 1992, Journal of chromatography.

[3]  G. Sauerbrey Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung , 1959 .

[4]  M. Thompson,et al.  The Potential of the Bulk Acoustic Wave Device as a Liquid-Phase Immunosensor , 1987, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  H. Gaub,et al.  Absolute quantities and equilibrium kinetics of macromolecular adsorption measured by fluorescence photobleaching in total internal reflection , 1990 .

[6]  D. Gerstenberg,et al.  Physics of Thin Films , 1964 .

[7]  P. Woias,et al.  A quartz crystal biosensor for measurement in liquids. , 1992, Biosensors & bioelectronics.

[8]  A Ahluwalia,et al.  A comparative study of protein immobilization techniques for optical immunosensors. , 1992, Biosensors & bioelectronics.

[9]  B. Liedberg,et al.  Surface plasmon resonance for gas detection and biosensing , 1983 .

[10]  E. Kretschmann Die Bestimmung optischer Konstanten von Metallen durch Anregung von Oberflächenplasmaschwingungen , 1971 .

[11]  Stephen J. Martin,et al.  Characterization of a quartz crystal microbalance with simultaneous mass and liquid loading , 1991 .

[12]  P. Woias,et al.  HIV serology using piezoelectric immunosensors , 1994 .

[13]  H. Wolf,et al.  Quartz crystal microbalance for immunosensing , 1994 .