Reference air kerma and kerma-area product as estimators of peak skin dose for fluoroscopically guided interventions.

PURPOSE To determine more accurate regression formulas for estimating peak skin dose (PSD) from reference air kerma (RAK) or kerma-area product (KAP). METHODS After grouping of the data from 21 procedures into 13 clinically similar groups, assessments were made of optimal clustering using the Bayesian information criterion to obtain the optimal linear regressions of (log-transformed) PSD vs RAK, PSD vs KAP, and PSD vs RAK and KAP. RESULTS Three clusters of clinical groups were optimal in regression of PSD vs RAK, seven clusters of clinical groups were optimal in regression of PSD vs KAP, and six clusters of clinical groups were optimal in regression of PSD vs RAK and K AP. Prediction of PSD using both RAK andKAP is significantly better than prediction of PSD with either RAK or KAP alone. The regression of PSD vs RAK provided better predictions of PSD than the regression of PSD vs KAP. The partial-pooling (clustered) method yields smaller mean squared errors compared with the complete-pooling method. CONCLUSION PSD distributions for interventional radiology procedures are log-normal. Estimates of PSD derived from RAK and KAP jointly are mos t accurate, followed closely byestimates derived from RAK alone. Estimates of PSD derived from KAP alone are the least accurate. Using a stochastic search approach, it is possible to cluster together certain dissimilar types of procedures to minimize the total error sum of squares.

[1]  Mahadevappa Mahesh,et al.  Radiation Dose Management for Fluoroscopically Guided Interventional Medical Procedures , 2012 .

[2]  Teresa Wu,et al.  Automatic Monitoring of Localized Skin Dose with Fluoroscopic and Interventional Procedures , 2011, Journal of Digital Imaging.

[3]  Jian-zhong Sun,et al.  Radiation doses in interventional radiology procedures , 2011 .

[4]  Donald L. Miller,et al.  Reference levels for patient radiation doses in interventional radiology: proposed initial values for U.S. practice. , 2009, Radiology.

[5]  Gabriel Bartal,et al.  Guidelines for patient radiation dose management. , 2009, Journal of vascular and interventional radiology : JVIR.

[6]  Y. Erdi,et al.  Estimating radiation doses to the skin from interventional radiology procedures for a patient population with cancer. , 2009, Journal of vascular and interventional radiology : JVIR.

[7]  H Thierens,et al.  A large-scale multicentre study of patient skin doses in interventional cardiology: dose-area product action levels and dose reference levels. , 2009, The British journal of radiology.

[8]  R. Padovani,et al.  Patient doses and dosimetric evaluations in interventional cardiology. , 2009, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[9]  Masayuki Zuguchi,et al.  Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures. , 2006, AJR. American journal of roentgenology.

[10]  G. Bernardi,et al.  Patient skin dosimetry in haemodynamic and electrophysiology interventional cardiology. , 2005, Radiation protection dosimetry.

[11]  H. Bosmans,et al.  Patient Dosimetry for X Rays Used in Medical Imaging , 2005, Journal of the ICRU.

[12]  Donald L. Miller,et al.  Radiation doses in interventional radiology procedures: the RAD-IR Study. Part III: Dosimetric performance of the interventional fluoroscopy units. , 2004, Journal of vascular and interventional radiology : JVIR.

[13]  Donald L. Miller,et al.  Quality improvement guidelines for recording patient radiation dose in the medical record. , 2004, Journal of vascular and interventional radiology : JVIR.

[14]  S. Reuter,et al.  SIR Gold Medal , 2004 .

[15]  Donald L. Miller,et al.  Radiation doses in interventional radiology procedures: the RAD-IR study: part II: skin dose. , 2003, Journal of vascular and interventional radiology : JVIR.

[16]  Donald L. Miller,et al.  Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose. , 2003, Journal of vascular and interventional radiology : JVIR.

[17]  Stephen Balter,et al.  Minimizing radiation-induced skin injury in interventional radiology procedures. , 2002, Radiology.

[18]  Stephen Balter,et al.  Comparison of four techniques to estimate radiation dose to skin during angiographic and interventional radiology procedures. , 2002, Journal of vascular and interventional radiology : JVIR.

[19]  J R Roelandt,et al.  Real-Time Quantification and Display of Skin Radiation During Coronary Angiography and Intervention , 2001, Circulation.

[20]  J. Valentin,et al.  Abstract: Avoidance of radiation injuries from medical interventional procedures, ICRP Publication 85 , 2000 .

[21]  G. Schwarz Estimating the Dimension of a Model , 1978 .

[22]  S. Shapiro,et al.  An Analysis of Variance Test for Normality (Complete Samples) , 1965 .

[23]  A. Elster,et al.  Patient Dose Reference Levels for Interventional Radiology: A National Approach , 2010 .

[24]  Donald L. Miller,et al.  Techniques to estimate radiation dose to skin during fluoroscopically guided procedures α . , 2002 .

[25]  R. Nicholson,et al.  Skin sparing in interventional radiology: the effect of copper filtration. , 2000, The British journal of radiology.

[26]  H. Akaike,et al.  Information Theory and an Extension of the Maximum Likelihood Principle , 1973 .