The use of CFD for predicting and optimizing the performance of air conditioning equipment

Abstract This paper reports on the use of CFD for predicting and improving the performance of a rooftop AC unit. The current work considered the hydrodynamic and thermal fields on the air flow side of the unit with exact modeling of fans and heat exchangers. This is in addition to predicting condensation on cooling coils. Because only the air flow side is considered, the evaporator and condenser compartments are decoupled and the solution in each section is established separately. In the evaporator compartment the flow is solved as a two-phase flow (gas and liquid) with the gas phase being composed of two species (dry air and water vapor). In the condenser section however, the flow is treated as a single phase flow. The exact modeling of heat exchangers and fans increased the grid size and computational cost, but resulted in realistic results and reliable model. A total of 31 million control volumes are used to model the evaporator and condenser sections. Results indicate the presence of several recirculation zones in the evaporator compartment. Sensible and latent cooling capacities for several design conditions predicted by the model are in close agreement with available experimental data. The differences between the total capacities predicted by the model in the evaporator section and those reported experimentally are within 2.7% for all cases considered. Predictions in the condenser section resulted in a load that is only 0.00136% different than the one calculated using experimental data. To improve the performance of the unit, six different modified designs of the evaporator coil are developed and tested. The newly modified designs are based on changing the coil inclination angle and/or number of fins per unit length for the same coil height and surface area. One of the designs resulted in 6.18% decrease in the cooling capacity, while the remaining modifications increased the cooling capacity by values ranging between 2.17% and 8.6%.

[1]  J.E.R. Coney,et al.  Airflow maldistribution and the performance of a packaged air conditioning unit evaporator , 2000 .

[2]  Suresh V. Garimella,et al.  Analysis of evaporating mist flow for enhanced convective heat transfer , 2010 .

[3]  Maria Pla Perujo Condensation of Water Vapor and Acid Mixtures from Exhaust Gases , 2005 .

[4]  Z. G. Xu,et al.  A numerical and experimental study of turbulent flow through the evaporator coil in an air-conditioning unit , 1996 .

[5]  Simone Moretti,et al.  Numerical analysis of heat removal enhancement with extended surfaces , 2007 .

[6]  M. W. Collins,et al.  Validation of turbulence models in a simulated air‐conditioning unit , 1998 .

[7]  T. Shih,et al.  A new k-ϵ eddy viscosity model for high reynolds number turbulent flows , 1995 .

[8]  W. Jones,et al.  The prediction of laminarization with a two-equation model of turbulence , 1972 .

[9]  B. Launder,et al.  Progress in the development of a Reynolds-stress turbulence closure , 1975, Journal of Fluid Mechanics.

[10]  R. E. Sonntag,et al.  Fundamentals of classical thermodynamics , 1973 .

[11]  SPRAY COOLING OF AIR-COOLED COMPACT HEAT EXCHANGERS , 1975 .

[12]  D. B. Spalding,et al.  Computer analysis of the three-dimensional flow and heat transfer in a steam generator , 1978 .

[13]  Masoud Rahimi,et al.  CFD modeling of flow and heat transfer in a thermosyphon , 2010 .

[14]  Effect of humid air flow rate on the filmwise condensation inside a vertical cooled pipe: numerical and experimental study , 1994 .

[15]  Wen-Quan Tao,et al.  3D numerical simulation on shell-and-tube heat exchangers with middle-overlapped helical baffles and continuous baffles – Part I: Numerical model and results of whole heat exchanger with middle-overlapped helical baffles , 2009 .

[16]  A. M. Al-Nasser,et al.  Optimization of a packaged air conditioning unit performance using an experimentally validated CFD model , 2003 .

[17]  T. Shih,et al.  A New K-epsilon Eddy Viscosity Model for High Reynolds Number Turbulent Flows: Model Development and Validation , 1994 .

[18]  G. Faeth Evaporation and combustion of sprays , 1983 .

[19]  M. W. Collins,et al.  CFD Prediction of Turbulent Recirculating Flow in an Industrial Packaged Air-Conditioning Unit , 1996 .

[20]  Keith E. Herold,et al.  Prandtl number effect on offset fin heat exchanger performance : experimental results , 1995 .

[21]  Dae-Young Lee,et al.  Cooling enhancement in an air-cooled finned heat exchanger by thin water film evaporation , 2003 .