Carbon-enhanced inductively coupled plasma mass spectrometric detection of arsenic and selenium and its application to arsenic speciation

Addition of carbon as methanol or ammonium carbonate to the aqueous analyte solutions in combination with increased plasma power input enhanced the inductively coupled plasma mass spectrometry (ICP-MS) signal intensities of arsenic and selenium. In the presence of the optimum 3% v/v methanol concentration the signal intensities achieved were about 4500–5000 counts s–1 per ng ml–1 of arsenic and about 700–1100 counts s–1 per ng ml–1 of selenium (82Se), corresponding to enhancement factors of 3.5–4.5 compared with aqueous solution for the two elements. Differences in sensitivity (calculated on the basis of analyte atom) were observed between the individual arsenic species and between the selenium species in aqueous as well as in carbon-added solutions. The presence of 3% v/v methanol in the analyte solutions doubled the level of the background signal for arsenic and selenium, but its fluctuation (noise) was not increased. Therefore, the observed increase in analyte sensitivity led to a similar increase in signal-to-noise ratio. The addition of carbon as ammonium carbonate enhanced the arsenic signal by a similar factor but caused severe contamination of the ICP-MS instrument by carbon. In the 3% v/v methanol solutions of arsenic and selenium the signal intensity from antimony (internal standard) was enhanced by a factor of 1.5, which indicates that the enhancement effect of the arsenic and selenium signals by methanol is only to a limited extent caused by improved sample transport/nebulization efficiency. It is proposed that an increased population of carbon ions or carbon-containing ions in the plasma facilitates a more complete ionization of analytes lower in ionization energy than carbon itself. The enhanced detection power for arsenic was applied to arsenic speciation by high-performance liquid chromatography (HPLC)–ICP-MS, and made possible the detection of the arsenocholine ion (AsC) in extracts of shrimp at the 5–10 ng g–1 concentration level. The limit of detection was improved by a factor of 3.4 after addition of methanol and was 4.7 ng g–1 as the AsC ion.

[1]  F. Vanhaecke,et al.  Elimination of interferences in the determination of arsenic and selenium in biological samples by inductively coupled plasma mass spectrometry , 1993 .

[2]  J. Mermet,et al.  Signal enhancement of elements due to the presence of carbon-containing compounds in inductively coupled plasma mass spectrometry , 1991 .

[3]  A. G. Harrison Chemical Ionization Mass Spectrometry , 1983 .

[4]  D. D. Fischer,et al.  Identification of a major selenium excretory product in rat urine. , 1969, Biochimica et biophysica acta.

[5]  C. Vandecasteele,et al.  ‘Zone model’ as an explanation for signal behaviour and non-spectral interferences in inductively coupled plasma mass spectrometry , 1993 .

[6]  S. Hansen,et al.  Arsenic speciation in seafood samples with emphasis on minor constituents: an investigation using high-performance liquid chromatography with detection by inductively coupled plasma mass spectrometry , 1993 .

[7]  S. Hansen,et al.  Speciation of eight arsenic compounds in human urine by high-performance liquid chromatography with inductively coupled plasma mass spectrometric detection using antimonate for internal chromatographic standardization , 1993 .

[8]  E. Evans,et al.  Interferences in inductively coupled plasma mass spectrometry. A review , 1993 .

[9]  Shiuh-Jen Jiang,et al.  Speciation of mercury by reversed-phase liquid chromatography with inductively coupled plasma mass spectrometric detection , 1993 .

[10]  S. Hansen,et al.  Separation of seven arsenic compounds by high-performance liquid chromatography with on-line detection by hydrogen–argon flame atomic absorption spectrometry and inductively coupled plasma mass spectrometry , 1992 .

[11]  K. Wolnik,et al.  Arsenic speciation by ion chromatography with inductively coupled plasma mass spectrometric detection. , 1992, The Analyst.

[12]  S. Soo,et al.  Use of nitrogen and hydrogen in inductively coupled plasma mass spectrometry , 1992 .

[13]  P. Quevauviller,et al.  Influence of chemical species on the determination of mercury in a biological matrix (cod muscle) using inductively coupled plasma mass spectrometry , 1992 .

[14]  E. Larsen Electrothermal atomic absorption spectrometry of inorganic and organic arsenic species using conventional and fast furnace programmes , 1991 .

[15]  M. Ford,et al.  Determination of arsenic in samples with high chloride content by inductively coupled plasma mass spectrometry , 1991 .

[16]  J. M. Craig,et al.  Investigations on mixed-gas plasmas produced by adding nitrogen to the plasma gas in ICP-MS , 1991 .

[17]  L. Ebdon,et al.  Effect of organic solvents and molecular gases on polyatomic ion interferences in inductively coupled plasma mass spectrometry , 1990 .

[18]  G. Horlick,et al.  A comparison of argon and mixed gas plasmas for inductively coupled plasma-mass spectrometry , 1990 .

[19]  H. Longerich Effect of nitric acid, acetic acid and ethanol on inductively coupled plasma mass spectrometric ion signals as a function of nebuliser gas flow, with implications on matrix suppression and enhancements , 1989 .

[20]  D. Beauchemin,et al.  Determination of arsenic species by high-performance liquid chromatography-inductively coupled plasma mass spectrometry , 1989 .

[21]  D. Hausler Trace element analysis of organic solutions using inductively coupled plasma-mass spectrometry , 1987 .

[22]  R. Hutton Application of inductively coupled plasma source mass spectrometry (ICP-MS) to the determination of trace metals in organics , 1986 .

[23]  A. L. Gray,et al.  Inductively coupled plasma source mass spectrometry using continuum flow ion extraction , 1983 .