A Novel Framework for Quantifying Accuracy and Precision of Event Detection Algorithms in FES-Cycling

Functional electrical stimulation (FES) is a technique used in rehabilitation, allowing the recreation or facilitation of a movement or function, by electrically inducing the activation of targeted muscles. FES during cycling often uses activation patterns which are based on the crank angle of the pedals. Dynamic changes in their underlying predefined geometrical models (e.g., change in seating position) can lead to desynchronised contractions. Adaptive algorithms with a real-time interpretation of anatomical segments can avoid this and open new possibilities for the automatic design of stimulation patterns. However, their ability to accurately and precisely detect stimulation triggering events has to be evaluated in order to ensure their adaptability to real-case applications in various conditions. In this study, three algorithms (Hilbert, BSgonio, and Gait Cycle Index (GCI) Observer) were evaluated on passive cycling inertial data of six participants with spinal cord injury (SCI). For standardised comparison, a linear phase reference baseline was used to define target events (i.e., 10%, 40%, 60%, and 90% of the cycle’s progress). Limits of agreement (LoA) of ±10% of the cycle’s duration and Lin’s concordance correlation coefficient (CCC) were used to evaluate the accuracy and precision of the algorithm’s event detections. The delays in the detection were determined for each algorithm over 780 events. Analysis showed that the Hilbert and BSgonio algorithms validated the selected criteria (LoA: +5.17/−6.34% and +2.25/−2.51%, respectively), while the GCI Observer did not (LoA: +8.59/−27.89%). When evaluating control algorithms, it is paramount to define appropriate criteria in the context of the targeted practical application. To this end, normalising delays in event detection to the cycle’s duration enables the use of a criterion that stays invariable to changes in cadence. Lin’s CCC, comparing both linear correlation and strength of agreement between methods, also provides a reliable way of confirming comparisons between new control methods and an existing reference.

[1]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[2]  T. Vetter,et al.  Agreement Analysis: What He Said, She Said Versus You Said , 2018, Anesthesia and analgesia.

[3]  C. Fattal,et al.  Standardizing fatigue-resistance testing during electrical stimulation of paralysed human quadriceps muscles, a practical approach , 2021, Journal of neuroengineering and rehabilitation.

[4]  P.J. Sinclair,et al.  The effect of joint angle on the timing of muscle contractions elicited by neuromuscular electrical stimulation , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[5]  K J Hunt,et al.  Comparison of stimulation patterns for FES-cycling using measures of oxygen cost and stimulation cost. , 2006, Medical engineering & physics.

[6]  D. Giavarina Understanding Bland Altman analysis , 2015, Biochemia medica.

[7]  P. Jacobs,et al.  Modes, Benefits, And Risks Of Voluntary And Electrically Induced Exercise In Persons With Spinal Cord Injury , 2001, The journal of spinal cord medicine.

[8]  M. J. Castro,et al.  A simple means of increasing muscle size after spinal cord injury: a pilot study , 1999, European Journal of Applied Physiology and Occupational Physiology.

[9]  E. Krueger,et al.  Fatigue in complete spinal cord injury and implications on total delay. , 2020, Artificial organs.

[10]  Benoît Sijobert,et al.  New Approach of Cycling Phases Detection to Improve FES-Pedaling in SCI Individuals , 2018, 2018 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[11]  S. Hahn Hilbert Transforms in Signal Processing , 1996 .

[12]  Bernard Espiau,et al.  Multisensor Input for CPG-Based Sensory---Motor Coordination , 2008, IEEE Transactions on Robotics.

[13]  J S Petrofsky,et al.  Outdoor bicycle for exercise in paraplegics and quadriplegics. , 1983, Journal of biomedical engineering.

[14]  Benoît Sijobert,et al.  FES-Induced Cycling in Complete SCI: A Simpler Control Method Based on Inertial Sensors , 2019, Sensors.

[15]  Hiroyuki Kawai,et al.  Closed-Loop Position and Cadence Tracking Control for FES-Cycling Exploiting Pedal Force Direction With Antagonistic Biarticular Muscles , 2019, IEEE Transactions on Control Systems Technology.

[16]  Kevin M. Foglyano,et al.  Cycle Training Using Implanted Neural Prostheses: Team Cleveland , 2017, European journal of translational myology.

[17]  C. S. Bickel,et al.  Neuromuscular Electrical Stimulation-Induced Resistance Training After SCI: A Review of the Dudley Protocol. , 2015, Topics in spinal cord injury rehabilitation.

[19]  M. Morris,et al.  The reliability of three-dimensional kinematic gait measurements: a systematic review. , 2009, Gait & posture.

[20]  A. Kralj,et al.  Use of functional electrical stimulation in the rehabilitation of patients with incomplete spinal cord injuries. , 1989, Journal of biomedical engineering.

[21]  Takashi Watanabe,et al.  Preliminary tests of a prototype FES control system for cycling wheelchair rehabilitation , 2013, 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR).

[22]  G. Mahon A Proposal for Strength-of-Agreement Criteria for Lin’s Concordance Correlation Coefficient , 2005 .

[23]  Boualem Boashash,et al.  Estimating and interpreting the instantaneous frequency of a signal. I. Fundamentals , 1992, Proc. IEEE.

[24]  Yasunobu Handa,et al.  Review: Clinical benefits of functional electrical stimulation cycling exercise for subjects with central neurological impairments , 2011 .

[25]  Kenneth J Hunt,et al.  Cardiorespiratory and power adaptations to stimulated cycle training in paraplegia. , 2008, Medicine and science in sports and exercise.

[26]  Antonio P.L. Bo,et al.  Cycling with Spinal Cord Injury: A Novel System for Cycling Using Electrical Stimulation for Individuals with Paraplegia, and Preparation for Cybathlon 2016 , 2017, IEEE Robotics & Automation Magazine.

[27]  P. Peckham,et al.  Functional electrical stimulation for neuromuscular applications. , 2005, Annual review of biomedical engineering.

[28]  Thomas Schauer,et al.  Robust Discrimination of Flexion and Extension Phases for Mobile Functional Electrical Stimulation (FES) Induced Cycling in Paraplegics , 2016 .

[29]  W. Mayr,et al.  Leg Powered Paraplegic Cycling System using Surface Functional Electrical Stimulation , 2001 .

[30]  P. Lugner,et al.  Dynamic simulation of FES-cycling: influence of individual parameters , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[31]  L. Lin,et al.  A concordance correlation coefficient to evaluate reproducibility. , 1989, Biometrics.

[32]  Jay R Hoffman,et al.  Agreement of Gait Events Detection during Treadmill Backward Walking by Kinematic Data and Inertial Motion Units , 2020, Sensors.

[33]  Roger Pissard-Gibollet,et al.  Continuous gait cycle index estimation for electrical stimulation assisted foot drop correction , 2014, Journal of NeuroEngineering and Rehabilitation.

[34]  Thomas Schauer,et al.  The Cybathlon RehaBike: Inertial-Sensor-Driven Functional Electrical Stimulation Cycling by Team Hasomed , 2017, IEEE Robotics & Automation Magazine.