A Review of Magnetic Resonance Imaging Compatible Manipulators in Surgery

Abstract Developments in magnetic resonance imaging (MRI), coupled with parallel progress in the field of computer-assisted surgery, mean that an ideal environment has been created for the development of MRI-compatible robotic systems and manipulators, capable of enhancing many types of surgical procedure. However, MRI does impose severe restrictions on mechatronic devices to be used in or around the scanners. In this article a review of the developments in the field of MRI-compatible surgical manipulators over the last decade is presented. The manipulators developed make use of different methods of actuation, but they can be reduced to four main groups: actuation transmitted through hydraulics, pneumatic actuators, ultrasonic motors based on the piezoceramic principle and remote manual actuation. Progress has been made concerning material selection, position sensing, and different actuation techniques, and design strategies have been implemented to overcome the multiple restrictions imposed by the MRI environment. Most systems lack the clinical validation needed to continue on to commercial products.

[1]  Tatsuo Arai,et al.  Robotic Assist for MR-Guided Surgery Using Leverage and Parallelepiped Mechanism , 2000, MICCAI.

[2]  Masakatsu G. Fujie,et al.  An MR-compatible master-slave manipulator with interchangeable surgical tools , 2003, CARS.

[3]  Yo-Sung Ho,et al.  Image Segmentation Based on Shape Space Modeling , 2002, EurAsia-ICT.

[4]  R. Gassert,et al.  Prototype fMRI compatible actuators , 2004 .

[5]  Gabor Fichtinger,et al.  Design of a novel MRI compatible manipulator for image guided prostate interventions , 2005, IEEE Transactions on Biomedical Engineering.

[6]  Essa Yacoub,et al.  Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast. , 2004, Journal of biomechanical engineering.

[7]  Ken Masamune,et al.  Micro-grasping Forceps Manipulator for MR-Guided Neurosurgery , 2002, MICCAI.

[8]  D. Beyersdorff,et al.  MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: initial results. , 2005, Radiology.

[9]  H Iseki,et al.  Development of an MRI-compatible needle insertion manipulator for stereotactic neurosurgery. , 1995, Journal of image guided surgery.

[10]  Frank G Shellock,et al.  Magnetic resonance safety update 2002: Implants and devices , 2002, Journal of magnetic resonance imaging : JMRI.

[11]  J. Schenck The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. , 1996, Medical physics.

[12]  Gabor Fichtinger,et al.  Transrectal Prostate Biopsy Inside Closed MRI Scanner with Remote Actuation, under Real-Time Image Guidance , 2002, MICCAI.

[13]  Etienne Burdet,et al.  An MR compatible robot technology , 2003, 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422).

[14]  Y. Matsuoka,et al.  Robotics for surgery. , 1999, Annual review of biomedical engineering.

[15]  Masakatsu G. Fujie,et al.  A magnetic resonance compatible surgical manipulator: part of a unified support system for the diagnosis and treatment of heart disease , 2003, Adv. Robotics.

[16]  Kenji Uchino Piezoelectric ultrasonic motors: overview , 1998 .

[17]  Ivan Bricault,et al.  CT and MR Compatible Light Puncture Robot: Architectural Design and First Experiments , 2004, MICCAI.