Assessment of quantification accuracy and image quality of a full‐body dual‐layer spectral CT system

Abstract The performance of a recently introduced spectral computed tomography system based on a dual‐layer detector has been investigated. A semi‐anthropomorphic abdomen phantom for CT performance evaluation was imaged on the dual‐layer spectral CT at different radiation exposure levels (CTDI vol of 10 mGy, 20 mGy and 30 mGy). The phantom was equipped with specific low‐contrast and tissue‐equivalent inserts including water‐, adipose‐, muscle‐, liver‐, bone‐like materials and a variation in iodine concentrations. Additionally, the phantom size was varied using different extension rings to simulate different patient sizes. Contrast‐to‐noise (CNR) ratio over the range of available virtual mono‐energetic images (VMI) and the quantitative accuracy of VMI Hounsfield Units (HU), effective‐Z maps and iodine concentrations have been evaluated. Central and peripheral locations in the field‐of‐view have been examined. For all evaluated imaging tasks the results are within the calculated theoretical range of the tissue‐equivalent inserts. Especially at low energies, the CNR in VMIs could be boosted by up to 330% with respect to conventional images using iDose/spectral reconstructions at level 0. The mean bias found in effective‐Z maps and iodine concentrations averaged over all exposure levels and phantom sizes was 1.9% (eff. Z) and 3.4% (iodine). Only small variations were observed with increasing phantom size (+3%) while the bias was nearly independent of the exposure level (±0.2%). Therefore, dual‐layer detector based CT offers high quantitative accuracy of spectral images over the complete field‐of‐view without any compromise in radiation dose or diagnostic image quality.

[1]  D. Sahani,et al.  Material Separation Using Dual-Energy CT: Current and Emerging Applications. , 2016, Radiographics : a review publication of the Radiological Society of North America, Inc.

[2]  R. Murty Effective Atomic Numbers of Heterogeneous Materials , 1965, Nature.

[3]  C. McCollough,et al.  Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality. , 2011, Medical physics.

[4]  Ian A Cunningham,et al.  Energy subtraction angiography is comparable to digital subtraction angiography in terms of iodine Rose SNR. , 2016, Medical physics.

[5]  W R Brody,et al.  A method for selective tissue and bone visualization using dual energy scanned projection radiography. , 1981, Medical physics.

[6]  Ami Altman,et al.  TU‐E‐210A‐03: A Double‐Layer Detector, Dual‐Energy CT — Principles, Advantages and Applications , 2009 .

[7]  T. Flohr,et al.  Accuracy of dual-energy computed tomography for the measurement of iodine concentration using cardiac CT protocols: validation in a phantom model , 2014, European Radiology.

[8]  Shuai Leng,et al.  Dual-energy CT-based monochromatic imaging. , 2012, AJR. American journal of roentgenology.

[9]  Mitchell M Goodsitt,et al.  Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner. , 2011, Medical physics.

[10]  Xinhua Li,et al.  Objective characterization of GE discovery CT750 HD scanner: gemstone spectral imaging mode. , 2011, Medical physics.

[11]  A. Macovski,et al.  Generalized image combinations in dual KVP digital radiography. , 1981, Medical physics.

[12]  M. Macari,et al.  Iodine quantification with dual-energy CT: phantom study and preliminary experience with renal masses. , 2011, AJR. American journal of roentgenology.

[13]  B. Hamm,et al.  Safety and tolerability of iobitridol in general and in patients with risk factors: results in more than 160,000 patients. , 2011, European journal of radiology.

[14]  Hugo A Katus,et al.  Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction. , 2012, European journal of radiology.

[15]  R. Nelson,et al.  Interdependencies of acquisition, detection, and reconstruction techniques on the accuracy of iodine quantification in varying patient sizes employing dual-energy CT , 2015, European Radiology.

[16]  W. Kalender,et al.  Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies. , 1986, Medical physics.

[17]  Hiroaki Naito,et al.  Dual-energy CT head bone and hard plaque removal for quantification of calcified carotid stenosis: utility and comparison with digital subtraction angiography , 2009, European Radiology.

[18]  M. Macari,et al.  Single-Phase Dual-Energy CT Allows for Characterization of Renal Masses as Benign or Malignant , 2010, Investigative radiology.

[19]  Thomas Koehler,et al.  Ultra Low Dose CT Pulmonary Angiography with Iterative Reconstruction , 2016, PloS one.

[20]  M. Reiser,et al.  Dual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical Experience , 2008, Investigative radiology.

[21]  Joon Beom Seo,et al.  Dual-energy CT for assessment of the severity of acute pulmonary embolism: pulmonary perfusion defect score compared with CT angiographic obstruction score and right ventricular/left ventricular diameter ratio. , 2010, AJR. American journal of roentgenology.

[23]  Ernst J. Rummeny,et al.  Does Iterative Reconstruction Lower CT Radiation Dose: Evaluation of 15,000 Examinations , 2013, PloS one.

[24]  M. Jinzaki,et al.  Abdominal CT: an intra-individual comparison between virtual monochromatic spectral and polychromatic 120-kVp images obtained during the same examination. , 2014, European journal of radiology.

[25]  C. McCollough,et al.  Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications. , 2015, Radiology.

[26]  K. Stierstorfer,et al.  First performance evaluation of a dual-source CT (DSCT) system , 2006, European Radiology.

[27]  D. Sahani,et al.  Virtual monochromatic reconstruction of dual-energy unenhanced head CT at 65-75 keV maximizes image quality compared with conventional polychromatic CT. , 2013, Radiology.

[28]  Konstantin Nikolaou,et al.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation , 2011, European Radiology.

[29]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[30]  W. Kalender,et al.  An algorithm for noise suppression in dual energy CT material density images. , 1988, IEEE transactions on medical imaging.

[31]  M. Kachelriess,et al.  Performance of today's dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: A simulation study. , 2015, Medical physics.

[32]  Antonio Vaamonde Liste,et al.  Quantitative myocardial perfusion with stress dual-energy CT: iodine concentration differences between normal and ischemic or necrotic myocardium. Initial experience , 2016, European Radiology.

[33]  Bo Wang,et al.  A pilot study using low-dose Spectral CT and ASIR (Adaptive Statistical Iterative Reconstruction) algorithm to diagnose solitary pulmonary nodules , 2015, BMC Medical Imaging.

[34]  C. McCollough,et al.  Detectability of urinary stones on virtual nonenhanced images generated at pyelographic-phase dual-energy CT. , 2010, Radiology.

[35]  Franz Pfeiffer,et al.  Spectral Photon-counting CT: Initial Experience with Dual-Contrast Agent K-Edge Colonography. , 2017, Radiology.

[36]  D. DeLong,et al.  Determining contrast medium dose and rate on basis of lean body weight: does this strategy improve patient-to-patient uniformity of hepatic enhancement during multi-detector row CT? , 2007, Radiology.

[37]  Amir Pourmorteza,et al.  Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience. , 2016, Radiology.

[38]  Julien Milles,et al.  Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT , 2017, European Radiology.

[39]  J. Ellis,et al.  Frequency, outcome, and appropriateness of treatment of nonionic iodinated contrast media reactions. , 2008, AJR. American journal of roentgenology.

[40]  Ernst J Rummeny,et al.  Initial performance characterization of a clinical noise-suppressing reconstruction algorithm for MDCT. , 2011, AJR. American journal of roentgenology.

[41]  Yoad Yagil,et al.  State of the Art of CT Detectors and Sources: A Literature Review , 2013, Current Radiology Reports.

[42]  L L Berland,et al.  Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: optimization of energy level viewing significantly increases lesion contrast. , 2013, Clinical radiology.

[43]  J. H. Hubbell,et al.  XCOM: Photon Cross Section Database (version 1.2) , 1999 .

[44]  J. Peterson,et al.  Clinical utility of dual-energy CT for evaluation of tophaceous gout. , 2011, Radiographics : a review publication of the Radiological Society of North America, Inc.

[46]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[47]  S. Hou,et al.  Hospital-acquired renal insufficiency. , 2002, American journal of kidney diseases : the official journal of the National Kidney Foundation.