Introducing gel dosimetry in a clinical environment: customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy.

Radiation sensitive gels have been used as dosimeters for clinical dose verification of different radiation therapy modalities. However, the use of gels is not widespread, because careful techniques are required to achieve the dose precision and accuracy aimed for in clinical dose verification. Here, the introduction of gel dosimetry in a clinical environment is described, including the whole chain of customizations and preparations required to introduce magnetic resonance (MR) based gel dosimetry into clinical routine. In order to standardize gel dosimetry in dose verifications for radiosurgery and intensity modulated radiotherapy (IMRT), we focused on both the customization of the gel composition and of the MR imaging parameters to increase its precision. The relative amount of the components of the normoxic, methacrylic acid based gel (MAGIC) was changed to obtain linear and steep dose response relationships. MR imaging parameters were customized for the different dose ranges used in order to lower the relative standard deviation of the measured transversal relaxation rate (R2). An optimization parameter was introduced to quantify the change in the relative standard deviation of R2 (sigma(R2,rel)) taking the increase in MR time into account. A 9% methacrylic acid gel customized for radiosurgery was found to give a linear dose response up to 40 Gy with a slope of 0.94 Gy(-1) s(-1), while a 6% methacrylic acid gel customized for IMRT had a linear range up to 3 Gy with a slope of 1.86 Gy(-1) s(-1). With the help of an introduced optimization parameter, the mean sigma(R2,rel) was improved by 13% for high doses and by 55% for low doses, without increasing MR time to unacceptable values. A mean dose resolution of less than 0.13 Gy has been achieved with the gel and imaging parameters customized for IMRT and a dose resolution from 0.97 Gy (at 5 Gy) to 2.15 Gy (at 40 Gy) for the radiosurgery dose range. The comparisons of calculated and measured relative 3D dose distributions performed for radiosurgery and IMRT showed an acceptable overall correlation. The gamma criterion for the radiosurgery verification with a voxel size of 1.5 x 1.5 x 1.5 mm3 was passed by 96.8% of the voxels (1.5 mm distance, 8% in dose). For the IMRT verification using a voxel size of 1.25 x 1.25 x 5 mm3 the gamma criterion was passed by 50.3% of the voxels (3 mm distance, 3% dose uncertainty). Using dedicated data analysis and visualization software, MR based normoxic gel dosimetry was found to be a valuable tool for clinically based dose verification, provided that customized gel compositions and MR imaging parameters are used. While high dose precision was achieved, further work is required to achieve clinically acceptable dose accuracy.

[1]  Lars E Olsson,et al.  MAGIC-type polymer gel for three-dimensional dosimetry: intensity-modulated radiation therapy verification. , 2003, Medical physics.

[2]  C. Baldock,et al.  Uncertainty analysis in polymer gel dosimetry. , 1999, Physics in medicine and biology.

[3]  Robert J. Shalek,et al.  Determination of Absorbed Dose in a Patient Irradiated by Beams of X or Gamma Rays in Radiotherapy Procedures , 1977 .

[4]  D. Porter,et al.  Dose resolution in radiotherapy polymer gel dosimetry: effect of echo spacing in MRI pulse sequence. , 2001, Physics in medicine and biology.

[5]  J. Gore,et al.  Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere. , 2001, Physics in medicine and biology.

[6]  S. Webb,et al.  Optimized MR imaging for polyacrylamide gel dosimetry. , 2000, Physics in medicine and biology.

[7]  L. Lüdemann,et al.  Use of BANG polymer gel for dose measurements in a 68 MeV proton beam. , 2003, Medical physics.

[8]  C. Baldock,et al.  Modelling of post-irradiation events in polymer gel dosimeters. , 2001, Physics in medicine and biology.

[9]  J. Buatti,et al.  Image registration of BANG gel dose maps for quantitative dosimetry verification. , 1999, International journal of radiation oncology, biology, physics.

[10]  Effect of container size on the accuracy of polymer gel dosimetry , 2006 .

[11]  M. Oldham,et al.  Optical-CT gel-dosimetry I: basic investigations. , 2003, Medical physics.

[12]  C De Wagter,et al.  The fundamental radiation properties of normoxic polymer gel dosimeters: a comparison between a methacrylic acid based gel and acrylamide based gels , 2006, Physics in medicine and biology.

[13]  C Baldock,et al.  Dose-response stability and integrity of the dose distribution of various polymer gel dosimeters. , 2002, Physics in medicine and biology.

[14]  D. Huyskens,et al.  A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  S Webb,et al.  Improving calibration accuracy in gel dosimetry. , 1998, Physics in medicine and biology.

[16]  Dose verification of single shot gamma knife applications using VIPAR polymer gel and MRI. , 2005, Physics in medicine and biology.

[17]  L. Sakelliou,et al.  Dose verification in clinical IMRT prostate incidents. , 2004, International journal of radiation oncology, biology, physics.

[18]  D. Low,et al.  A technique for the quantitative evaluation of dose distributions. , 1998, Medical physics.

[19]  J C Gore,et al.  Effects of crosslinking and temperature on the dose response of a BANG polymer gel dosimeter. , 1997, Physics in medicine and biology.

[20]  E. Stiliaris,et al.  Polymer gel dosimetry close to an 125I interstitial brachytherapy seed , 2005, Physics in medicine and biology.

[21]  A Ertl,et al.  High-resolution polymer gel dosimetry by parameter selective MR-microimaging on a whole body scanner at 3T. , 2001, Medical physics.

[22]  Y. D. Deene,et al.  Optimization of multiple spin-echo sequences for 3D polymer gel dosimetry. , 2002, Physics in medicine and biology.

[23]  C Duzenli,et al.  Technical considerations for implementation of x-ray CT polymer gel dosimetry , 2005, Physics in medicine and biology.

[24]  R. Liščák,et al.  Quality control of the stereotactic radiosurgery procedure with the polymer-gel dosimetry. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[25]  J C Gore,et al.  Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter , 1994, Physics in medicine and biology.

[26]  S. Webb,et al.  The use of gel dosimetry for verification of electron and photon treatment plans in carcinoma of the scalp , 2004, Physics in medicine and biology.

[27]  C Baldock,et al.  A basic study of some normoxic polymer gel dosimeters. , 2002, Physics in medicine and biology.

[28]  M. Smith,et al.  Reply to 'Comment on 'A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry''. , 2003, Physics in medicine and biology.

[29]  P J Keall,et al.  Radiological properties of normoxic polymer gel dosimeters. , 2005, Medical physics.