An alternative hemostatic dressing: comparison of CELOX, HemCon, and QuikClot.

OBJECTIVES Uncontrolled hemorrhage remains a leading cause of traumatic death. Several topical adjunct agents have been shown to be effective in controlling hemorrhage, and two, chitosan wafer dressing (HemCon [HC]) and zeolite powder dressing (QuikClot [QC]), are being utilized regularly on the battlefield. However, recent literature reviews have concluded that no ideal topical agent exists. The authors compared a new chitosan granule dressing (CELOX [CX]) to HC, QC and standard dressing in a lethal hemorrhagic groin injury. METHODS A complex groin injury with transection of the femoral vessels and 3 minutes of uncontrolled hemorrhage was created in 48 swine. The animals were then randomized to four treatment groups (12 animals each). Group 1 included standard gauze dressing (SD); Group 2, CX; Group 3, HC; and Group 4, QC. Each agent was applied with 5 minutes of manual pressure followed by a standard field compression dressing. Hetastarch (500 mL) was infused over 30 minutes. Hemodynamic parameters were recorded over 180 minutes. Primary endpoints included rebleed and death. RESULTS CX reduced rebleeding to 0% (p < 0.001), HC to 33% (95% CI = 19.7% to 46.3%, p = 0.038), and QC to 8% (95% CI = 3.3% to 15.7%, p = 0.001), compared to 83% (95% CI = 72.4% to 93.6%) for SD. CX improved survival to 100% compared to SD at 50% (95% CI = 35.9% to 64.2%, p = 0.018). Survival for HC (67%) (95% CI = 53.7% to 80.3%) and QC (92%; 95% CI = 84.3% to 99.7%) did not differ from SD. CONCLUSIONS In this porcine model of uncontrolled hemorrhage, CX improved hemorrhage control and survival. CELOX is a viable alternative for the treatment of severe hemorrhage.

[1]  Anthony E. Pusateri,et al.  The Chitosan-Based Hemostatic Dressing: Experience in Current Combat Operations. , 2005, The Journal of trauma.

[2]  Peter Rhee,et al.  Comparative analysis of hemostatic agents in a swine model of lethal groin injury. , 2003, The Journal of trauma.

[3]  A. Sauaia,et al.  Predicting life-threatening coagulopathy in the massively transfused trauma patient: hypothermia and acidoses revisited. , 1997, The Journal of trauma.

[4]  Peter Rhee,et al.  Battlefield casualties treated at Camp Rhino, Afghanistan: lessons learned. , 2003, The Journal of trauma.

[5]  J. Holcomb,et al.  Comparison of hemorrhage control agents applied to lethal extremity arterial hemorrhages in swine. , 2005, The Journal of trauma.

[6]  Peter Rhee,et al.  Application of a zeolite hemostatic agent achieves 100% survival in a lethal model of complex groin injury in Swine. , 2004, The Journal of trauma.

[7]  K. Ryan,et al.  Application of a granular mineral-based hemostatic agent (QuikClot) to reduce blood loss after grade V liver injury in swine. , 2004, The Journal of trauma.

[8]  J. Holcomb,et al.  Comparison of 10 different hemostatic dressings in an aortic injury. , 2003, The Journal of trauma.

[9]  A. Pope,et al.  Fluid Resuscitation: State of the Science for Treating Combat Casualties and Civilian Injuries , 1999 .

[10]  Ari Leppaniemi,et al.  A profile of combat injury. , 2003, The Journal of trauma.

[11]  Richard A. Harris,et al.  Advanced hemostatic dressing development program: animal model selection criteria and results of a study of nine hemostatic dressings in a model of severe large venous hemorrhage and hepatic injury in Swine. , 2003, The Journal of trauma.

[12]  Kathy L Ryan,et al.  Making sense of the preclinical literature on advanced hemostatic products. , 2006, The Journal of trauma.

[13]  P. Rhee,et al.  Testing of modified zeolite hemostatic dressings in a large animal model of lethal groin injury. , 2006, The Journal of trauma.

[14]  J. Holcomb,et al.  Effect of dry fibrin sealant dressings versus gauze packing on blood loss in grade V liver injuries in resuscitated swine. , 1998, The Journal of trauma.

[15]  L. D. Yantis,et al.  Thermal injury resulting from application of a granular mineral hemostatic agent. , 2004, The Journal of trauma.

[16]  A. Pusateri,et al.  A case Series Describing Thermal Injury Resulting From Zeolite Use for Hemorrhage Control in Combat Operations , 2007, Prehospital emergency care : official journal of the National Association of EMS Physicians and the National Association of State EMS Directors.

[17]  A. Sauaia,et al.  Early predictors of postinjury multiple organ failure. , 1994, Archives of surgery.

[18]  D. E. Perkins,et al.  United States Army Rangers in Somalia: an analysis of combat casualties on an urban battlefield. , 2000, The Journal of trauma.

[19]  A. Sauaia,et al.  Epidemiology of trauma deaths: a reassessment. , 1993, The Journal of trauma.

[20]  F. Lewis,et al.  Epidemiology of trauma deaths. , 1980, American journal of surgery.

[21]  Richard A. Harris,et al.  Effect of a chitosan-based hemostatic dressing on blood loss and survival in a model of severe venous hemorrhage and hepatic injury in swine. , 2003, The Journal of trauma.

[22]  M. Copass,et al.  Outcome after hemorrhagic shock in trauma patients. , 1998, The Journal of trauma.

[23]  Peter Rhee,et al.  Hemorrhage control in the battlefield: role of new hemostatic agents. , 2005, Military medicine.