Finite element stress analysis of dental prostheses supported by straight and angled implants.

PURPOSE A three-dimensional finite element analysis was conducted to evaluate and compare the stress distribution around two prosthesis-implant systems, in which implants were arranged in either a straight-line or an intrabone offset configuration. MATERIALS AND METHODS The systems were modeled with three titanium implants placed in the posterior mandible following a straight line along the bone. The straight system was built with three straight implants (no offset). The angled system was built as follows: the first implant (mesial) was an angled implant inclined lingually, the second (median) was straight, and the third (distal) was another angled implant inclined buccally. This buccal incline created an intrabone implant offset owing to the inclination of the angled implants' bodies. Each system received a metal-ceramic prosthesis with crowns that mimicked premolar anatomy. In both systems, an axial load of 100 N and a horizontal load of 20 N were applied on the center of the crown of the middle implant. RESULTS In both systems, the major von Mises stresses occurred with vertical loading on the mesial and the distal neck area of the first and third implants, respectively: 6.304 MPa on the first implant of the straight system and 6.173 MPa on the third implant in the angled system. The peak stress occurred for the minimum principal stress (S3) on the neck of the first implant for both systems at the level of -8.835 MPa for the straight system and -8.511 MPa for the angled system. There was no stress concentration on the inner or outer angles of the angled implants, on the notches along the implant body, or on any apex. CONCLUSIONS In this analysis, the angled system did not induce a stress concentration in any point around the implants that was different from that of the straight system. The stress distribution was very similar in both systems.

[1]  S E Eckert,et al.  Retrospective review of 1170 endosseous implants placed in partially edentulous jaws. , 1998, The Journal of prosthetic dentistry.

[2]  George A. Zarb,et al.  Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry , 1985 .

[3]  C. Bourauel,et al.  Bone loading pattern around implants in average and atrophic edentulous maxillae: a finite-element analysis. , 2001, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[4]  J. F. Fleming,et al.  Comparison of two-dimensional and three-dimensional finite element analysis of a blade implant. , 1987, The International journal of oral implantology : implantologist.

[5]  J K Lee,et al.  A three-dimensional finite element stress analysis of angled abutments for an implant placed in the anterior maxilla. , 1995, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[6]  B Rangert,et al.  Forces and moments on Branemark implants. , 1989, The International journal of oral & maxillofacial implants.

[7]  E. M. Toledo,et al.  Finite element stress analysis of cuneiform and cylindrical threaded implant geometries. , 2006, Technology and health care : official journal of the European Society for Engineering and Medicine.

[8]  H. Iplikçioğlu,et al.  Finite element stress analysis of the influence of staggered versus straight placement of dental implants. , 2001, The International journal of oral & maxillofacial implants.

[9]  P. Glantz,et al.  Vertical load distribution on a three-unit prosthesis supported by a natural tooth and a single Brånemark implant. An in vivo study. , 1995, Clinical oral implants research.

[10]  Ş. Canay,et al.  Comparison of stress distribution around vertical and angled implants with finite-element analysis. , 1996, Quintessence international.

[11]  M. Ash,et al.  Wheeler's Dental Anatomy, Physiology and Occlusion , 1992 .

[12]  L A Weinberg,et al.  A comparison of implant/prosthesis loading with four clinical variables. , 1995, The International journal of prosthodontics.

[13]  D H DeTolla,et al.  Role of the finite element model in dental implants. , 2000, The Journal of oral implantology.

[14]  Ismail Yh,et al.  Comparison of two-dimensional and three-dimensional finite element analysis of a blade implant. , 1987 .

[15]  P. Branemark,et al.  Reconstruction of the defective mandible. , 1975, Scandinavian journal of plastic and reconstructive surgery.

[16]  R. James,et al.  The experimental verification of the efficacy of finite element modeling to dental implant systems. , 1996, The Journal of oral implantology.

[17]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[18]  J. Cawood,et al.  A classification of the edentulous jaws. , 1988, International journal of oral and maxillofacial surgery.

[19]  Alper Çağlar,et al.  Effects of mesiodistal inclination of implants on stress distribution in implant-supported fixed prostheses. , 2006, The International journal of oral & maxillofacial implants.

[20]  C. A. Cimini,et al.  Comparative 3D finite element stress analysis of straight and angled wedge-shaped implant designs. , 2008, The International journal of oral & maxillofacial implants.

[21]  T D Taylor,et al.  Implant prosthodontics: current perspective and future directions. , 2000, The International journal of oral & maxillofacial implants.

[22]  Angel Abbud-Madrid Osseointegration in Skeletal Reconstruction and Joint Replacement , 2000 .

[23]  G. Zarb,et al.  Osseointegrated implants for partially edentulous patients. Interim considerations. , 1987, Dental clinics of North America.

[24]  H. Iplikçioğlu,et al.  Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone. , 2002, Journal of dentistry.

[25]  J. H. Koolstra,et al.  The jaw open-close movements predicted by biomechanical modelling. , 1997, Journal of biomechanics.

[26]  F Sutter,et al.  Indications for angled implants. , 1992, The Journal of prosthetic dentistry.

[27]  L. Sennerby,et al.  Histology of retrieved immediately and early loaded oxidized implants: light microscopic observations after 5 to 9 months of loading in the posterior mandible. , 2003, Clinical implant dentistry and related research.

[28]  M. Quirynen,et al.  Biologic outcome of implant-supported restorations in the treatment of partial edentulism. Part 2: a longitudinal radiographic study. , 2002, Clinical oral implants research.

[29]  Afonso C. C. Lemonge,et al.  Three-dimensional finite element stress analysis of a cuneiform-geometry implant. , 2003, The International journal of oral & maxillofacial implants.

[30]  K. An,et al.  Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone. , 2004, The International journal of oral & maxillofacial implants.

[31]  G Van der Perre,et al.  The influence of bone mechanical properties and implant fixation upon bone loading around oral implants. , 1998, Clinical oral implants research.

[32]  Norio Inou,et al.  Functional Adaptation of Mandibular Bone , 1996 .

[33]  S E Eckert,et al.  Analysis of incidence and associated factors with fractured implants: a retrospective study. , 2000, The International journal of oral & maxillofacial implants.

[34]  S. Lewis Anterior single-tooth implant restorations. , 1995, The International journal of periodontics & restorative dentistry.

[35]  G A Niznick,et al.  Bending overload and implant fracture: a retrospective clinical analysis. , 1996, The International journal of oral & maxillofacial implants.

[36]  G. Zarb,et al.  Implant prosthodontic management of posterior partial edentulism: long-term follow-up of a prospective study. , 2002, Journal.

[37]  B Rangert,et al.  Design, maintenance and biomechanical considerations in implant placement. , 1997, Dental update.

[38]  L. A. Weinberg,et al.  An evaluation of torque (moment) on implant/prosthesis with staggered buccal and lingual offset. , 1996, The International journal of periodontics & restorative dentistry.

[39]  S. Bayne,et al.  Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function. , 1996, The Journal of prosthetic dentistry.

[40]  Haruka Kusakari,et al.  Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. , 2003, The International journal of oral & maxillofacial implants.

[41]  J. Cawood,et al.  Reconstructive preprosthetic surgery. I. Anatomical considerations. , 1991, International journal of oral and maxillofacial surgery.

[42]  M. Quirynen,et al.  Biologic outcome of implant-supported restorations in the treatment of partial edentulism. part I: a longitudinal clinical evaluation. , 2002, Clinical oral implants research.

[43]  P. Glantz,et al.  Functional loads on freestanding and connected implants in three-unit mandibular prostheses opposing complete dentures: an in vivo study. , 1997, The International journal of oral & maxillofacial implants.

[44]  V K Goel,et al.  Experimental validation of a finite element model of the temporomandibular joint. , 2001, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[45]  T. Jemt,et al.  Load factor control for implants in the posterior partially edentulous segment. , 1997, The International journal of oral & maxillofacial implants.

[46]  Y Akagawa,et al.  A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region. , 2000, Journal of oral rehabilitation.

[47]  O. Miyakawa,et al.  Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis. , 1998, The International journal of oral & maxillofacial implants.

[48]  A. Hannam,et al.  Three-dimensional finite element stress analysis of the dentate human mandible. , 1992, American journal of physical anthropology.

[49]  D. Buser,et al.  The new concept of ITI hollow-cylinder and hollow-screw implants: Part 1. Engineering and design. , 1988, The International journal of oral & maxillofacial implants.

[50]  L. Borchers,et al.  Three-dimensional Stress Distribution Around a Dental Implant at Different Stages of Interface Development , 1983, Journal of dental research.

[51]  T M van Eijden,et al.  Application and validation of a three-dimensional mathematical model of the human masticatory system in vivo. , 1992, Journal of biomechanics.

[52]  Yong-Geun Choi,et al.  Comparison of dental implant systems: quality of clinical evidence and prediction of 5-year survival. , 2005, The International journal of oral & maxillofacial implants.