Finite element stress analysis of dental prostheses supported by straight and angled implants.
暂无分享,去创建一个
Elson Magalhães Toledo | E. M. Toledo | M. Cruz | T. Wassall | Mauro Cruz | Thomaz Wassall | Luis Paulo da Silva Barra | Silvia Cruz | Silvia Cruz
[1] S E Eckert,et al. Retrospective review of 1170 endosseous implants placed in partially edentulous jaws. , 1998, The Journal of prosthetic dentistry.
[2] George A. Zarb,et al. Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry , 1985 .
[3] C. Bourauel,et al. Bone loading pattern around implants in average and atrophic edentulous maxillae: a finite-element analysis. , 2001, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.
[4] J. F. Fleming,et al. Comparison of two-dimensional and three-dimensional finite element analysis of a blade implant. , 1987, The International journal of oral implantology : implantologist.
[5] J K Lee,et al. A three-dimensional finite element stress analysis of angled abutments for an implant placed in the anterior maxilla. , 1995, Journal of prosthodontics : official journal of the American College of Prosthodontists.
[6] B Rangert,et al. Forces and moments on Branemark implants. , 1989, The International journal of oral & maxillofacial implants.
[7] E. M. Toledo,et al. Finite element stress analysis of cuneiform and cylindrical threaded implant geometries. , 2006, Technology and health care : official journal of the European Society for Engineering and Medicine.
[8] H. Iplikçioğlu,et al. Finite element stress analysis of the influence of staggered versus straight placement of dental implants. , 2001, The International journal of oral & maxillofacial implants.
[9] P. Glantz,et al. Vertical load distribution on a three-unit prosthesis supported by a natural tooth and a single Brånemark implant. An in vivo study. , 1995, Clinical oral implants research.
[10] Ş. Canay,et al. Comparison of stress distribution around vertical and angled implants with finite-element analysis. , 1996, Quintessence international.
[11] M. Ash,et al. Wheeler's Dental Anatomy, Physiology and Occlusion , 1992 .
[12] L A Weinberg,et al. A comparison of implant/prosthesis loading with four clinical variables. , 1995, The International journal of prosthodontics.
[13] D H DeTolla,et al. Role of the finite element model in dental implants. , 2000, The Journal of oral implantology.
[14] Ismail Yh,et al. Comparison of two-dimensional and three-dimensional finite element analysis of a blade implant. , 1987 .
[15] P. Branemark,et al. Reconstruction of the defective mandible. , 1975, Scandinavian journal of plastic and reconstructive surgery.
[16] R. James,et al. The experimental verification of the efficacy of finite element modeling to dental implant systems. , 1996, The Journal of oral implantology.
[17] P I Brånemark,et al. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.
[18] J. Cawood,et al. A classification of the edentulous jaws. , 1988, International journal of oral and maxillofacial surgery.
[19] Alper Çağlar,et al. Effects of mesiodistal inclination of implants on stress distribution in implant-supported fixed prostheses. , 2006, The International journal of oral & maxillofacial implants.
[20] C. A. Cimini,et al. Comparative 3D finite element stress analysis of straight and angled wedge-shaped implant designs. , 2008, The International journal of oral & maxillofacial implants.
[21] T D Taylor,et al. Implant prosthodontics: current perspective and future directions. , 2000, The International journal of oral & maxillofacial implants.
[22] Angel Abbud-Madrid. Osseointegration in Skeletal Reconstruction and Joint Replacement , 2000 .
[23] G. Zarb,et al. Osseointegrated implants for partially edentulous patients. Interim considerations. , 1987, Dental clinics of North America.
[24] H. Iplikçioğlu,et al. Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone. , 2002, Journal of dentistry.
[25] J. H. Koolstra,et al. The jaw open-close movements predicted by biomechanical modelling. , 1997, Journal of biomechanics.
[26] F Sutter,et al. Indications for angled implants. , 1992, The Journal of prosthetic dentistry.
[27] L. Sennerby,et al. Histology of retrieved immediately and early loaded oxidized implants: light microscopic observations after 5 to 9 months of loading in the posterior mandible. , 2003, Clinical implant dentistry and related research.
[28] M. Quirynen,et al. Biologic outcome of implant-supported restorations in the treatment of partial edentulism. Part 2: a longitudinal radiographic study. , 2002, Clinical oral implants research.
[29] Afonso C. C. Lemonge,et al. Three-dimensional finite element stress analysis of a cuneiform-geometry implant. , 2003, The International journal of oral & maxillofacial implants.
[30] K. An,et al. Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone. , 2004, The International journal of oral & maxillofacial implants.
[31] G Van der Perre,et al. The influence of bone mechanical properties and implant fixation upon bone loading around oral implants. , 1998, Clinical oral implants research.
[32] Norio Inou,et al. Functional Adaptation of Mandibular Bone , 1996 .
[33] S E Eckert,et al. Analysis of incidence and associated factors with fractured implants: a retrospective study. , 2000, The International journal of oral & maxillofacial implants.
[34] S. Lewis. Anterior single-tooth implant restorations. , 1995, The International journal of periodontics & restorative dentistry.
[35] G A Niznick,et al. Bending overload and implant fracture: a retrospective clinical analysis. , 1996, The International journal of oral & maxillofacial implants.
[36] G. Zarb,et al. Implant prosthodontic management of posterior partial edentulism: long-term follow-up of a prospective study. , 2002, Journal.
[37] B Rangert,et al. Design, maintenance and biomechanical considerations in implant placement. , 1997, Dental update.
[38] L. A. Weinberg,et al. An evaluation of torque (moment) on implant/prosthesis with staggered buccal and lingual offset. , 1996, The International journal of periodontics & restorative dentistry.
[39] S. Bayne,et al. Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function. , 1996, The Journal of prosthetic dentistry.
[40] Haruka Kusakari,et al. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. , 2003, The International journal of oral & maxillofacial implants.
[41] J. Cawood,et al. Reconstructive preprosthetic surgery. I. Anatomical considerations. , 1991, International journal of oral and maxillofacial surgery.
[42] M. Quirynen,et al. Biologic outcome of implant-supported restorations in the treatment of partial edentulism. part I: a longitudinal clinical evaluation. , 2002, Clinical oral implants research.
[43] P. Glantz,et al. Functional loads on freestanding and connected implants in three-unit mandibular prostheses opposing complete dentures: an in vivo study. , 1997, The International journal of oral & maxillofacial implants.
[44] V K Goel,et al. Experimental validation of a finite element model of the temporomandibular joint. , 2001, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.
[45] T. Jemt,et al. Load factor control for implants in the posterior partially edentulous segment. , 1997, The International journal of oral & maxillofacial implants.
[46] Y Akagawa,et al. A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region. , 2000, Journal of oral rehabilitation.
[47] O. Miyakawa,et al. Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis. , 1998, The International journal of oral & maxillofacial implants.
[48] A. Hannam,et al. Three-dimensional finite element stress analysis of the dentate human mandible. , 1992, American journal of physical anthropology.
[49] D. Buser,et al. The new concept of ITI hollow-cylinder and hollow-screw implants: Part 1. Engineering and design. , 1988, The International journal of oral & maxillofacial implants.
[50] L. Borchers,et al. Three-dimensional Stress Distribution Around a Dental Implant at Different Stages of Interface Development , 1983, Journal of dental research.
[51] T M van Eijden,et al. Application and validation of a three-dimensional mathematical model of the human masticatory system in vivo. , 1992, Journal of biomechanics.
[52] Yong-Geun Choi,et al. Comparison of dental implant systems: quality of clinical evidence and prediction of 5-year survival. , 2005, The International journal of oral & maxillofacial implants.