Optical performance analysis of V‐trough PV concentrators

This paper proposes a method for the analysis of the optical losses that take place inside PV concentrators, which is useful in the design of such systems. The study is focused in V-trough concentrators with two-axis tracking. Those are low concentration systems that use nearly conventional flat PV modules. Optical losses are shown to depend on the cavity angle, the mirrors spectral and angular reflectance and the surfaces dirtiness. Final effective concentration ratio and relative cost should consider all these analysed factors. This will help in the search of the most efficient solution in each case. Copyright © 2008 John Wiley & Sons, Ltd.