Polyaniline-uricase biosensor prepared with template process.

Polyaniline (PANI) uricase biosensor prepared with template process is reported first in this paper. The fabrication process is as follows. Firstly, a PANI-uricase electrode is obtained using one-step process. Secondly, the electrode is hydrolyzed in 6.0 mol/dm(3) hydrochloric acid solution to remove the uricase that may be affected by aniline monomer from PANI film. Finally, active uricase is immobilized into the PANI film based on the principle of the doping and undoping of the conducting polymer and a PANI-uricase biosensor is obtained. Some factors that affect response current are studied, such as temperature, pH, potential and substrate concentration. The determination of biosensors indicates that the response current of the biosensor prepared by template process decreases only by about 18% for 60 days, but that prepared by two-step process decreases by approximately 39% for 40 h. The uricase in PANI-uricase biosensor prepared by template process mainly interacts with the nitrogen linked to the quinoid ring. The biosensor is characterized with FTIR, UV-Vis and SEM for the first time.

[1]  Asha Chaubey,et al.  Application of conducting polymers to biosensors. , 2002, Biosensors & bioelectronics.

[2]  C. Kochansky,et al.  Determination of uremic toxins in biofluids: creatinine, creatine, uric acid and xanthines. , 2000, Journal of chromatography. B, Biomedical sciences and applications.

[3]  M. Umaña,et al.  Protein-modified electrodes. The glucose oxidase/polypyrrole system , 1986 .

[4]  A P Turner,et al.  Biosensors--Sense and Sensitivity , 2000, Science.

[5]  M. Snaith Gout: diet and uric acid revisited , 2001, The Lancet.

[6]  Mu Shaolin,et al.  BIOELECTROCHEMICAL RESPONSES OF THE POLYANILINE GLUCOSE OXIDASE ELECTRODE , 1991 .

[7]  Stuart I. Yaniger,et al.  “Polyaniline”: Interconversion of Metallic and Insulating Forms , 1985 .

[8]  I. Karube,et al.  Direct electron transfer with glucose oxidase immobilized in an electropolymerized poly( N-methylpyrrole) film on a gold microelectrode , 1990 .

[9]  G. S. Wilson,et al.  Rotating ring-disk enzyme electrode for surface catalysis studies. , 1976, Analytical chemistry.

[10]  Mu Shaolin,et al.  Effect of α,α′-bipyridine on activity of the polyaniline uricase electrode , 1996 .

[11]  Christopher R. Lowe,et al.  Enzyme entrapment in electrically conducting polymers. Immobilisation of glucose oxidase in polypyrrole and its application in amperometric glucose sensors , 1986 .

[12]  H. Britton,et al.  LXI.—The use of the antimony–antimonous oxide electrode in the determination of the concentration of hydrogen ions and in potenliometric titrations. The Prideaux–Ward universal buffer mixture , 1931 .

[13]  L. C. Clark,et al.  ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY , 1962 .

[14]  Mu Shaolin Bioelectrochemical response of the polyaniline galactose oxidase electrode , 1994 .

[15]  Chen Hong,et al.  Effects of conducting polymers on immobilized galactose oxidase , 1997 .

[16]  Itamar Willner,et al.  Biomaterials for Sensors, Fuel Cells, and Circuitry , 2002, Science.

[17]  D. Bélanger,et al.  Electrochemistry of the polypyrrole glucose oxidase electrode , 1989 .

[18]  A. Monkman,et al.  Structural characterisation of polyaniline free standing films , 1991 .

[19]  Mu Shaolin,et al.  Bioelectrochemical responses of the polyaniline uricase electrode , 1992 .