Measurement of intraocular pressure after epikeratophakia

AIMS To assess the accuracy of three commonly used tonometers in eyes after epikeratophakia. METHODS Five eye bank eyes with sutured epikeratophakia buttons were connected to a manometer and a pressure transducer. Intraocular pressure was adjusted in 5 mm Hg increments from 0 to 50 mm Hg. The intraocular pressure was measured at each increment using a Goldmann tonometer, a pneumatonometer, and a Tono-pen. RESULTS The difference between the manometer (actual pressure) and the Goldmann tonometer ranged from −19 to + 9 mm Hg (mean (SD) overestimation 2.6 (5.8) mm Hg). The pneumatonometer error ranged from −27.5 to + 5.5 mm Hg (mean (SD) overestimation 4.7 (6.1) mm Hg), and for the Tono-pen the range was −18 to + 11 mm Hg (mean (SD) overestimation 0.05 (7.9) mm Hg). The correlation coefficients for the three tonometers were 0.94, 0.92, and 0.87 for the Goldmann tonometer, pneumatonometer, and Tono-pen respectively. CONCLUSION The Goldmann tonometer had the best correlation with the manometer in eye bank eyes with epikeratophakia (correlation coefficient 0.94), but none of the tonometers was accurate over the entire range of pressures tested. Detection of glaucoma in eyes with epikeratophakia cannot rely on tonometry alone, but requires examination of the optic nerve and visual field.

[1]  R. Stein,et al.  The effect of corneal thickness on applanation tonometry. , 1993, American journal of ophthalmology.

[2]  M. M. Wright,et al.  Measurement of intraocular pressure with a flat anterior chamber. , 1991, Ophthalmology (Rochester, Minn.).

[3]  C. Summers,et al.  A prospective study of ocular hypertension and glaucoma after pediatric cataract surgery. , 1995, Ophthalmology.

[4]  W. A. Boothe,et al.  The Tono-Pen. A manometric and clinical study. , 1988, Archives of ophthalmology.

[5]  M. R. Jain,et al.  A clinical evaluation of the applanation pneumatonograph. , 1976, The British journal of ophthalmology.

[6]  T. A. Armstrong Evaluation of the Tono-Pen and the Pulsair tonometers. , 1990, American journal of ophthalmology.

[7]  M. B. Shields,et al.  An evaluation of the Tono-Pen for the measurement of diurnal intraocular pressure. , 1989, American journal of ophthalmology.

[8]  P. Lichter,et al.  Clinical comparison of the Oculab Tono-Pen to the Goldmann applanation tonometer. , 1987, Ophthalmology.

[9]  D. Shin,et al.  Comparison of the Tono-Pen to the Goldmann applanation tonometer. , 1988, Archives of ophthalmology.

[10]  R. Rössler,et al.  Comparison of intraocular pressure measurements with the Oculab Tono-Pen vs manometry in humans shortly after death. , 1988, American journal of ophthalmology.

[11]  H. Thompson,et al.  Accuracy and precision of the Tono-Pen in measuring intraocular pressure after keratoplasty and epikeratophakia and in scarred corneas. , 1988, Archives of ophthalmology.

[12]  H. Kaufman,et al.  Measurement of intraocular pressure after epikeratophakia. , 1983, Archives of ophthalmology.

[13]  N. Ehlers,et al.  APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESS , 1975, Acta ophthalmologica.

[14]  R A Moses,et al.  Increased corneal thickness simulating elevated intraocular pressure. , 1978, Archives of ophthalmology.

[15]  H. Quigley,et al.  Comparative intraocular pressure measurements with the pneumatonograph and Goldmann tonometer. , 1975, American journal of ophthalmology.

[16]  J. Parel,et al.  Comparative tonometric measurements of eye bank eyes. , 1987, Cornea.