A low-volume platform for cell-respirometric screening based on quenched-luminescence oxygen sensing.

Cell viability assays represent an important technology in modern cell biology, drug discovery and biotechnology, where currently there is a high demand for simple, sensitive and cost-effective screening methods. We have developed a new methodology and associated tools for cell-based screening assays, which are based on the measurement of the rates of oxygen uptake in cells by luminescence quenching. Sealable microchamber devices matching the footprint of a standard 96-well plate were developed and used in conjunction with long-decay phosphorescent oxygen probes. These devices permit cell non-invasive, real-time monitoring of cellular respiration and a rapid, one-step, kinetic assessment of multiple samples for cell viability, drug/effector action. These assays can be carried out on conventional fluorescence plate readers, they are suitable for different types of cells, including adherent and slow-respiring cells, require small sample volumes and cell numbers, and are amenable for high throughput screening. Monitoring of as little as 300 mammalian cells in 3 microl volume has been demonstrated.

[1]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[2]  H. Kautsky Energie‐Umwandlungen an Grenzflächen, IV. Mitteil.: H. Kautsky und A. Hirsch: Wechselwirkung zwischen angeregten Farbstoff‐Molekülen und Sauerstoff , 1931 .

[3]  Dmitri B. Papkovsky,et al.  Fluorescence-Based Cell Viability Screening Assays Using Water-Soluble Oxygen Probes , 2003, Journal of biomolecular screening.

[4]  T. Mosmann Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays. , 1983, Journal of immunological methods.

[5]  S. Ahmed,et al.  A new rapid and simple non-radioactive assay to monitor and determine the proliferation of lymphocytes: an alternative to [3H]thymidine incorporation assay. , 1994, Journal of immunological methods.

[6]  M. King Detection of dead cells and measurement of cell killing by flow cytometry. , 2000, Journal of immunological methods.

[7]  Benjamin A. DeGraff,et al.  Peer Reviewed: Oxygen Sensors Based on Luminescence Quenching. , 1999 .

[8]  M. Brunet,et al.  Advanced photoresist technologies for microsystems , 2001 .

[9]  M. Gray,et al.  Sensitive determination of cell number using the CyQUANT cell proliferation assay. , 2001, Journal of immunological methods.

[10]  D. Buckley,et al.  A cell viability assay based on monitoring respiration by optical oxygen sensing. , 2000, Analytical biochemistry.

[11]  W. Barnikol,et al.  Ein neues Mikroverfahren zur kontinuierlichen und verbrauchsfreien Bestimmung der zellulären Sauerstoffaufnahme auf Basis der Fluoreszenzlöschung - A New Micromethod Employing Fluorescence Quenching for the Continuous Measurement of Cellular Oxygen Uptake Without Consuming Oxygen , 1998 .

[12]  G. Guilbault,et al.  An immunosensor based on the glucose oxidase label and optical oxygen detection. , 1999, Analytical chemistry.

[13]  R. Oriol,et al.  A reliable, rapid and inexpensive two-color fluorescence assay to monitor serum cytotoxicity in xenotransplantation. , 1999, Journal of immunological methods.

[14]  J. Bruce Pitner,et al.  Novel Fluorescent Technology Platform for High Throughput Cytotoxicity and Proliferation Assays , 2000, Journal of biomolecular screening.

[15]  W. Rumsey,et al.  Imaging of phosphorescence: a novel method for measuring oxygen distribution in perfused tissue. , 1988, Science.

[16]  N. T. Stewart,et al.  Traditional and emerging methods for analyzing cell activity in cell culture. , 2000, Methods in cell science : an official journal of the Society for In Vitro Biology.

[17]  S. Zanetti,et al.  Evaluation of a nonradiometric system (BACTEC 9000 MB) for detection of mycobacteria in human clinical samples , 1997, Journal of clinical microbiology.